PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Fluorescence imaging”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Analysis of cholesterol ester accumulation in macrophages by the use of digital imaging fluorescence microscopy.

Low density lipoprotein (LDL) induced accumulation of cholesterol esters was analyzed by the digital imaging fluorescence microscopy (DIFM) in murine tumor macrophages. To analyze cholesterol ester accumulation, P388D1 macrophages were incubated with increasing quantities of unmodified or acetylated human LDL, washed, and live stained with a lipophylic fluorescent dye Nile Red. The increase in fluorescence intensity was quantitatively determined by the interactive laser cytometer (ACAS 470) and compared with the accumulation of cellular cholesterol esters determined by the gas liquid chromatography. Correlation between the two methods was highly significant (r greater than 0.9, P less than 0.001). A good agreement between the two methods was also found in terms of sensitivity and reproducibility. With the use of 589 nm narrowband interference filter in the light path of emitted light the intensity of fluorescence correlated well with cellular cholesterol ester content even in the presence of relatively high concentrations of triglycerides. Therefore, digital imaging fluorescence microscopy appears to be a reliable method for quantification of cholesterol ester accumulation at the single cell level offering new possibilities of studying interactions between cells and cholesterol ester rich lipoproteins.

Animals↗

3-D cell-level chlorophyll fluorescence imaging of ozone-injured sunflower leaves using a new passive light microscope system.

A passive light microscope system has been developed, capable of reconstructing an extended-focus 3-D cell-level image of chlorophyll fluorescence and Phi(PSII) of intact attached leaves using a limited number of focal plane images of chlorophyll fluorescence. Using this system, the relationships between the depth of the mesophyll cells in spongy tissue and the intensity of the chlorophyll fluorescence and the Phi(PSII) were investigated in sunflower leaves exposed to 300 ppb ozone for 12 h at a PPFD of 300 micromol m(-2) s(-1) actinic light. After ozone exposure, fluorescence intensity (F) largely decreased in the cells just under the epidermal cells (within approximately 20 microm of the epidermal cells), but the sites where fluorescence intensity decreased had no relationship to the position of the stomata. By contrast, the distribution of Phi(PSII) showed no change after the ozone exposure. These findings suggest that ozone-induced inhibition occurs in the cells just under the epidermal cells by reducing the light absorption of the chloroplasts, while the operating quantum efficiency of PSII photochemistry is maintained.

Algorithms↗

Fluorescence-imaging assay for cytotoxic plaque formation and for growth toward confluency of adherent cells.

A nondestructive fluorescence-imaging assay is described for quantitating the number and size of plaques formed over time by cytotoxic effector cells in a monolayer of target cells. It can also be used to assay the growth of adherent cells toward confluence. The method involves the use of fluorescein conjugated to high molecular weight dextran. The dextran is excluded by adherent cells, thereby making the medium around cells more fluorescent than the cells themselves. The area of the plate that is fluorescent can be determined by confocal fluorescence imaging microscopy. With this new method, changes in the confluency of adherent cells or in the number and area of cytotoxic plaques can be assayed repeatedly over an extended period of time, without manipulation of the cells or of the medium.

Cell Adhesion↗

Fluorescence imaging of extracellular purinergic receptor sites and putative ecto-ATPase sites on isolated cochlear hair cells.

Fluorescence imaging of extracellular adenosine-5'-triphosphate (ATP) binding sites on inner and outer hair cells isolated from the guinea pig organ of Corti was achieved using the fluorescent analog of ATP, 2'-(or-3')-O-(trinitrophenyl)adenosine-5'- triphosphate (TNP-ATP; 30-75 microM). This analog, which fluoresces on binding to these sites, was pressure applied by micropipette while hair cells were viewed by fluorescence microscopy. Fluorescence imaging revealed a widespread distribution of extracellular binding sites, including the stereocilia, cuticular plate, and the basolateral margins of the cells, but particularly in infracuticular and infranuclear regions. In support of extracellular binding, simultaneous electrophysiological recordings demonstrated that rapid washout of TNP-ATP-induced fluorescence was dependent upon cell integrity. Suramin, a nonselective P2 purinoceptor antagonist, coapplied with TNP-ATP, reduced the fluorescence observed on the stereocilia and apical surface of the cuticular plate only. This implies that binding sites on the apical surface of hair cells are P2 receptors, consistent with previous electrophysiological evidence for localization of P2 receptors to the apical surface of cochlear hair cells (Housley et al., 1992). Binding of TNP-ATP to P2 purinoceptors was confirmed by its antagonism of the inward current elicited by ATP (10 microM) in voltage-clamped hair cells. Fluorescence from the basolateral margin was significantly quenched when TNP-ATP was applied in divalent cation-free solution. Because divalent cations are required for ATPase activity, this finding provides evidence for the presence of ecto-ATPases on the basolateral membrane of hair cells. The divalent cation-free condition had no significant effect on the ATP-gated P2 purinoceptor conductance. We propose that there are two classes of ATP binding sites on cochlear hair cells: apically located P2 purinoceptors gating nonselective cation channels and basolaterally located ecto-ATPases that may be involved in purine turnover.

Adenosine Triphosphatases↗

Fluorescence imaging of single molecules in polymer microspheres.

We report on far-field fluorescence imaging of single molecules in spherical polymer microparticles produced from solution by using microdroplet techniques. The fluorescence photobleaching quantum yields of rhodamine 6G in a common water-soluble polymer (polyvinyl alcohol) are at least five times smaller, corresponding to proportionally larger average fluorescence signals, than those in ethanolic solvents. This allows for acquisition of multiple images from a single molecule on a time scale of several minutes. We also show that fluorescent images of single molecules in microspheres can be calculated from semiclassic electrodynamics, which may ultimately be useful in retrieving dynamical information from experimental images.

Fluorescence↗

Fluorescence imaging and spectroscopy of ethyl nile blue A in animal models of (pre)malignancies.

Discrimination between normal and premalignant tissues by fluorescence imaging and/or spectroscopy may be enhanced by a tumor-localizing fluorescent drug. Ethyl Nile Blue A (EtNBA), a dye with no phototoxic activity, was investigated for this purpose. The pharmacokinetics and tissue-localizing properties were investigated in a rat palate model with chemically induced premalignant mucosal lesions (0.5 mg/kg EtNBA intravenous [i.v.]), a hairless mouse model with UVB-induced premalignant skin lesions (1 mg/kg EtNBA intraperitoneal) and in a rat skin-fold observation chamber model on the back of a rat with a transplanted solid tumor (2.5 mg/kg EtNBA i.v.). Fluorescence images and spectra were recorded in vivo (600 nm excitation, 665-900 nm detection) and in frozen tissue sections at several time points after EtNBA administration. In the rat palate the EtNBA fluorescence was maximum almost immediately after injection, whereas in the mouse skin and the observation chamber the fluorescence maximum was reached between 2 and 3 h after injection. EtNBA cleared from tissues after 8-24 h. EtNBA localizes in the transplantable solid tumor, but is not targeted specifically to the dysplastic location in the rat palate and mouse skin. However, in the rat palate the EtNBA fluorescence increased significantly with increasing dysplasia, apparently due to the increasing thickness of the upper keratinized layer of the epithelium where the dye was found to localize. Localization in this layer occurred both in the rat palate and in hairless mouse skin.

Animals↗

Quantitative fluorescence image analysis in bladder cancer screening.

Quantitative fluorescence image analysis (QFIA) cytology combines image analysis to measure DNA with visual cytology for bladder cancer detection. QFIA sensitivity is 76% to 81% and 95% to 100% for low- and high-grade tumors respectively, with 94% specificity in asymptomatic controls. QFIA screening of 504 persons within a beta-naphthylamine exposed cohort found DNA hyperploidy correlated with the duration of carcinogenic exposure and smoking history; marker prevalence was 23% for exposed workers who smoked and 2% for nonexposed nonsmokers. In prospective animal studies, QFIA was useful in monitoring carcinogenesis and chemoprevention with retinoids. Current QFIA research focuses on measurements of oncogenes, growth factors and their receptors, cytoskeleton, and tumor-associated antigens to improve sensitivity and specificity to low-grade tumors and to identify premalignant conditions. Profiles of biochemical and immunological markers on single cells may further assist in the study of high-risk cohorts and individual risk assessment.

Biomarkers, Tumor↗

Time-resolved fluorescence imaging of islet cell autoantibodies.

Time-resolved fluorescence of lanthanide chelates has been widely used in bioanalytical assays. Long fluorescence time, large Stokes shift, and minute fading out of the fluorescence over years are major advantages of the lanthanides over the conventional fluorescent dyes. We have now applied time-resolved fluorescence imaging (TRFI) also for measurement of type 1 diabetes mellitus (T1DM)-related islet cell autoantibodies (ICA). Retaining the accuracy of conventional ICA, TRFI has over 10 times better signal-to-noise ratio than the conventional fluorochromes. The technology allows objective determination of fluorescence intensity with the camera and computer software, and serial dilutions for obtaining the antibody titer in autoantibody-positive samples are unnecessary. We now describe the TRFI as a method and its application for measurement of ICA.

Autoantibodies↗

Development of novel fluorescent probe 3-perylene diphenylphosphine for determination of lipid hydroperoxide with fluorescent image analysis.

A novel fluorescent probe 3-perylene diphenylphosphine (3-PeDPP) was synthesized for the direct analysis of lipid hydroperoxides. The structure of 3-PeDPP was identified by the spectroscopic data, FAB-MS, (1)H NMR, and (13)C NMR. The reactivities of 3-PeDPP with lipid hydroperoxides were investigated in chloroform/MeOH homogeneous solutions and PC liposome model systems oxidized by either 2,2'-azobis(2-amidinopropane)dihydrochloride and photosensitized oxidation. The fluorescence intensity derived from 3-perylene diphenylphosphineoxide (3-PeDPPO) increased proportionally with amount of hydroperoxides produced in homogeneous solutions and liposome model systems. 3-PeDPP was easily incorporated into mouse myeloma SP2 cells and thin tissue section for dynamic membrane lipid peroxidation studies. Linear correlations between fluorescence intensity and amount of hydroperoxides in the cell membrane and tissue sections were obtained. The fluorescence intensity from 2-dimensional image analysis was also well correlated with lipid hydroperoxide level in these models. Thus, the novel probe 3-PeDPP is useful for the direct determination of lipid hydroperoxides in biological materials.

Animals↗

Epi-fluorescence imaging of colloid transport in porous media at decimeter scales.

A noninvasive epi-fluorescence imaging technique was developed for real-time observation of colloid transport in porous media at decimeter scales. Fluorescent latex microspheres and translucent quartz sand were used as a model colloid-porous medium system. Various calibrations were performed for accurate conversion of fluorescence intensities to microsphere concentrations. Fluorescence intensities were found to linearly increase with microsphere concentrations (5 x 10(5)-5 x 10(8) spheres/mL in saturated sand) and with camera exposure time. Fluorescence intensities also increased with sand thickness (saturated with microsphere solution), indicating that the fluorescence signals detected by the imaging system were integrated signals from the entire thickness (10 mm) of the sand. A set of microsphere transport experiments was conducted to demonstrate the versatility of the imaging system. Excellent mass recoveries (93-103%) were achieved in all transport experiments, demonstrating the robustness of the imaging system for quantitative study of colloid transport. The system allowed the change of flow velocity, ionic strength, and flow direction within one transport experiment and the real-time, quantitative monitoring of the movement of microspheres in packed sand, greatly reducing the time and effort needed for similar work with traditional column experiments.

Colloids↗

DNA content by in situ fluorescence imaging and S-phase detection, with chromatin structure preserved.

OBJECTIVE: To test the feasibility of in situ DNA quantitation of adherent cells' nuclei by fluorescence imaging, preserving chromatin structure and to follow-up S phase, in relation to DNA content, in order to assess the precision of DNA measurements. STUDY DESIGN: Double labeling experiments involved total DNA staining with Hoechst 33342 and BrdU immunostaining (after either Br photolysis and DNA strand break labeling by terminal transferase or acid denaturation) to detect replicating DNA. An epifluorescence microscope was used, images captured with a CCD camera and quantitative total DNA measurements done in 12 bits with IPLab software. BrdU results were related to DNA content on an individual cell basis. Cell cycle analyses were run with Imastat software (developed in the laboratory) on Hoechst-stained cells and on double labeled cells. RESULTS: In cells progressing through the cycle, as assessed by BrdU, a corresponding increase in DNA content was measured. Early S differed from G1 (P < .05). Imastat analyses gave a CV for GI peak of 6-7%. CONCLUSION: Quantitative fluorescence imaging allows a sensitive determination of DNA content for adherent-cell nuclei in situ. Topologic analyses of nuclear components will be possible in relation to DNA content.

3T3 Cells↗

Electrochemical modulation of remote fluorescence imaging at an ordered opto-electrochemical nanoaperture array.

An array of nanometer-sized apertures capable of electrochemically modulating the fluorescence of a model analyte is presented. The device, which combines near-field optical methods and ultramicroelectrode properties in an array format, is based on an etched coherent optical fiber bundle. Indeed, the fabrication steps produced an ordered array where each optical nanoaperture is surrounded by a ring-shaped gold nanoelectrode. The chronoamperometric behavior of the array shows stable diffusion-limited quasi-steady-state response. The model analyte, tris(2,2'-bipyridine) ruthenium, emits fluorescence in the Ru(II) state, but not in the oxidized Ru(III) state. Fluorescence is excited by visible light exiting from each nanoaperture since light is confined to the tip apex by the gold coating. A fraction of the isotropically emitted luminescence is collected by the same nanoaperture, transmitted by the corresponding fiber core and eventually detected by a charge-coupled device (CCD) camera. The array format provides a fluorescence image resolved at the nanometric scale which covers a large micrometric area. Therefore the high-density array plays a bridging role between these two fundamental scales. We established that the opto-electrochemical nanoapertures are optically independent. Fluorescence of the sample collected by each nanoaperture is modulated by changing the potential of the nanoring electrodes. Reversible electrochemical switching of remote fluorescence imaging is performed through the opto-electrochemical nanoaperture array itself. Eventually this ordered structure of nanometer light sources which are electrochemically manipulated provides promising photonic or electro-optical devices for various future applications. For example, such an array has potential in the development of a combined SNOM-electrochemical nanoprobe array to image a real sample concomitantly at the nanometer and micrometer scale.

Journal Article↗

Combined optical and fluorescence imaging for breast cancer detection and diagnosis.

In this article, we present a novel approach that combines the best aspects of both endogenous optical imaging and exogenous fluorescent lifetime and yield imaging for breast cancer detection and diagnosis. Using this approach, spatial distributions of optical properties, fluorescence lifetime, and yield in tissue can be reconstructed from measured excitation and emission data at the surface of the breast tissue by regularized inverse algorithms. We show images from simulated data, as well as images from experimental data using tissue-like phantom materials in the laboratory.

Algorithms↗

Phenotyping transgenic embryos: a rapid 3-D screening method based on episcopic fluorescence image capturing.

We describe a technique suitable for routine three-dimensional (3-D) analysis of mouse embryos that is based on episcopic fluorescence images captured during serial sectioning of wax-embedded specimens. We have used this procedure to describe the cardiac phenotype and associated blood vessels of trisomic 16 (Ts16) and Cited2-null mutant mice, as well as the expression pattern of an Myf5 enhancer/beta-galactosidase transgene. The consistency of the images and their precise alignment are ideally suited for 3-D analysis using video animations, virtual resectioning or commercial 3-D reconstruction software packages. Episcopic fluorescence image capturing (EFIC) provides a simple and powerful tool for analyzing embryo and organ morphology in normal and transgenic embryos.

Abnormalities, Multiple↗

An intraoperative fluorescent imaging system in organ transplantation.

UNLABELLED: An intraoperative fluorescent imaging system (SPY system; Novadaq Technologies, Inc, Concord, Ontario, Canada) that enables vascular surgeons to confirm the location and states of the reconstructed vessels during surgery, has been developed in the field of open heart surgery. In this paper, we evaluated the usefulness of the SPY system in kidney and liver transplantation. PATIENTS AND METHODS: SPY system visualizes arteries and grafts intraoperatively, using indocyanine green (ICG) with a portable imaging device. The modality was evaluated in 15 patients undergoing kidney (n = 13) or liver (n = 2) transplantation with respect to safety, feasibility of use, and image quality. Images were generated and acquired with a portable laser diode/infrared camera device after injection of 10 mL of ICG (2.5 mg/mL) intravenously. RESULT: There was no complication associated with ICG injection or the imaging device. The SPY system was easily used during transplant surgery and adequately demonstrated reconstructed arteries and patency in all patients. CONCLUSION: The intraoperative imaging system enables the surgeon to view, record, and replay real-time images of the reconstructed arteries during surgery. The system may provide useful information during surgery such as solid organ transplantation that requires vascular reconstruction.

Fluorescein Angiography↗

Near-field scanning optical microscopy probes: a comparison of pulled and double-etched bent NSOM probes for fluorescence imaging of biological samples.

Bent near-field optical probes for biological applications have been fabricated using a combination of a two-step chemical etching method and focused ion beam milling to create a well-defined aperture. The transmission efficiencies have been evaluated as a function of laser wavelength (lambda) and aperture size (D) for both large and small core fibres. The probe transmission behaviour follows a (D/lambda)3 relationship. The double-etched probes are compared to pulled probes fabricated from highly GeO2-doped dispersion compensating fibre and a standard single-mode optical fibre. The transmission efficiencies of both types of pulled probes are approximately two orders of magnitude lower than double-etched probes with similar aperture sizes. To demonstrate the utility of the various probes, their imaging performance has been evaluated for samples of polymer beads and phase-separated phospholipid monolayers of dipalmitoylphosphatidylcholine or cholesterol/phosphatidylcholine/sphingomyelin mixtures. Both pulled and double-etched probes are suitable for fluorescence imaging of polymer spheres. However, pulled probes are rapidly damaged at the higher input laser intensities required for fluorescence imaging of monolayer samples doped with < 1% of a fluorescent dye-labelled lipid. The images obtained with the double-etched probes show excellent spatial resolution and signal/noise, illustrating the potential of such probes for imaging of biological samples.

Microscopy, Atomic Force↗

Time-resolved fluorescence imaging of europium chelate label in immunohistochemistry and in situ hybridization.

Fluorescent lanthanide chelates with long decay times allow the suppression of the fast decaying autofluorescence in biological specimens. This property makes lanthanide chelates attractive as labels for fluorescence microscopy. As a consequence of the suppression of the background fluorescence the sensitivity can be increased. We modified a standard epifluorescence microscope for time-resolved fluorescence imaging by adding a pulsed light source and a chopper in the narrow aperture plane. A cooled CCD-camera was used for detection and the images were digitally processed. A fluorescent europium chelate was conjugated to antisera and to streptavidin. These conjugates were used for the localization of tumor associated antigen C242 in the malignant mucosa of human colon, for the localization of type II collagen mRNA in developing human cartilaginary growth plates, and for the detection of HPV type specific gene sequences in the squamous epithelium of human cervix. The specific slowly decaying fluorescence of the europium label could be effectively separated from the fast decaying background fluorescence. It was possible to use the europium label at the cell and tissue level and the autofluorescence was effectively suppressed in in situ hybridization and immunohistochemical reactions in both frozen and formaldehyde-fixed, wax-embedded specimens.

Alkaline Phosphatase↗