PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microchip Analytical Procedures”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7Linked to original sources

Quantitative 3D mapping of fluidic temperatures within microchannel networks using fluorescence lifetime imaging.

We describe a novel method for quantitatively mapping fluidic temperature with high spatial resolution within microchannels using fluorescence lifetime imaging in an optically sectioning microscope. Unlike intensity-based measurements, this approach is independent of experimental parameters, such as dye concentration and excitation/detection efficiency, thereby facilitating quantitative temperature mapping. Micrometer spatial resolution of 3D temperature distributions is readily achieved with an optical sectioning approach based on two-photon excitation. We demonstrate this technique for mapping of temperature variations across a microfluidic chip under different heating profiles and for mapping of the 3D temperature distribution across a single microchannel under applied flow conditions. This technique allows optimization of the chip design for miniaturized processes, such as on-chip PCR, for which precise temperature control is important.

Energy Transfer↗

Integrated preconcentration SDS-PAGE of proteins in microchips using photopatterned cross-linked polyacrylamide gels.

The potential of integration of functions in microfluidic chips is demonstrated by implementing on-chip preconcentration of proteins prior to on-chip protein sizing by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Two polymeric elements-a thin (approximately 50 microm) size exclusion membrane for preconcentration and a longer (approximately cm) porous monolith for protein sizing-were fabricated in situ using photopolymerization. Contiguous placement of the two polymeric elements in the channels of a microchip enabled simple and zero dead volume integration of the preconcentration with SDS-PAGE. The size exclusion membrane was polymerized in the injection channel using a shaped laser beam, and the sizing monolith was cast by photolithography using a mask and UV lamp. Proteins injected electrophoretically were trapped on the upstream side of the size exclusion membrane (MW cutoff approximately 10 kDa) and eluted off the membrane by reversing the electric field. Subsequently, the concentrated proteins were separated in a cross-linked polyacrylamide monolith that was patterned contiguous to the size exclusion membrane. The extent of protein preconcentration is easily tuned by varying the voltage during injection or by controlling the sample volume loaded. Electric fields applied across the nanoporous membrane resulted in a concentration polarization effect evidenced by decreasing current over time and irreproducible migration of proteins during sizing. To minimize the concentration polarization effect, sieving gels were polymerized only on the separation side of the membrane, and an alternate electrical current path was employed, bypassing the membrane, for most of the elution and separation steps. Electrophoretically sweeping a fixed sample volume against the membrane yields preconcentration factors that are independent of protein mobility. The volume sweeping method also avoids biased protein loading from concentration polarization and sample matrix variations. Mobilities of the concentrated proteins were log-linear with respect to molecular weight, demonstrating the suitability of this approach for protein sizing. Proteins were concentrated rapidly (<5 min) over 1000-fold followed by high-resolution separation in the sieving monolith. Proteins with concentrations as low as 50 fM were detectable with 30 min of preconcentration time. The integrated preconcentration-sizing approach facilitates analysis of low-abundant proteins that cannot be otherwise detected. Moreover, the integrated preconcentration-analysis approach employing in situ formation of photopatterned polymeric elements provides a generic, inexpensive, and versatile method to integrate functions at chip level and can be extended to lowering of detection limits for other applications such as DNA analysis and clinical diagnostics.

Acrylic Resins↗

Microchip-based macroporous silica sol-gel monolith for efficient isolation of DNA from clinical samples.

Effective microchip extraction of deoxyribonucleic acid (DNA) from crude biological matrixes has been demonstrated using silica beads or hybrid phases composed of beads and sol-gel. However, the use of monolithic sol-gels alone for extraction of human genomic DNA has been more difficult to define. Here we describe, for the first time, the successful use of monolithic tetramethyl orthosilicate-based sol-gels for effective micro-solid-phase extraction (muSPE) of DNA in a glass microchip format. A functional monolithic silica phase with micrometer-scale pores in the silica matrix resulted from addition of poly(ethylene glycol), a poragen, to the precursor mixture. This allowed a monolithic sol-gel bed to be established in a microchip channel that provided large surface area for DNA extraction with little flow-induced back pressure. DNA extraction efficiencies for simple systems (lambda-phage DNA) were approximately 85%, while efficiencies for the reproducible extraction of human genomic DNA from complex biological matrixes (human blood) were approximately 70%. Blockage of the sol-gel pores by components in the lysed blood was observed in repeat extraction on a single device as a decrease in the extraction efficiency. The developed muSPE protocol was further evaluated to show applicability to clinical samples and bacterial cultures, through extraction of PCR-amplifiable DNA.

DNA↗

Double-cross hydrostatic pressure sample injection for chip CE: variable sample plug volume and minimum number of electrodes.

A novel sample injection method for chip CE was presented. This injection method uses hydrostatic pressure, generated by emptying the sample waste reservoir, for sample loading and electrokinetic force for dispensing. The injection was performed on a double-cross microchip. One cross, created by the sample and separation channels, is used for formation of a sample plug. Another cross, formed by the sample and controlling channels, is used for plug control. By varying the electric field in the controlling channel, the sample plug volume can be linearly adjusted. Hydrostatic pressure takes advantage of its ease of generation on a microfluidic chip, without any electrode or external pressure pump, thus allowing a sample injection with a minimum number of electrodes. The potential of this injection method was demonstrated by a four-separation-channel chip CE system. In this system, parallel sample separation can be achieved with only two electrodes, which is otherwise impossible with conventional injection methods. Hydrostatic pressure maintains the sample composition during the sample loading, allowing the injection to be free of injection bias.

Electrodes↗

Bead-assisted displacement immunoassay for staphylococcal enterotoxin B on a microchip.

A microchip-based, displacement immunoassay for the sensitive laser-induced fluorescence detection of staphylococcal enterotoxin B is presented. The glass microchip device consists of a microchannel that contains a double weir structure for supporting antibody-functionalized microbeads. After a 30-min sample preparation step, the displacement assay was performed without user intervention and produced quantitative results in an additional 20 min. Linear detection responses were observed over 6 orders of magnitude and provided detection limits down to 1 fM (28.5 fg/mL). The surprisingly low detection limits are hypothesized to arise from field-based enrichment analogous to field-amplified stacking, chromatographic effects, and limited diffusion lengths in the microbead bed. The assay was challenged with bovine serum albumin, casein, and milk sample matrixes. This system has the potential to provide highly sensitive detection capabilities for target biomolecules.

Animals↗

Electrohydrodynamic generation and delivery of monodisperse picoliter droplets using a poly(dimethylsiloxane) microchip.

We developed a drop-on-demand microdroplet generator for the discrete dispensing of biosamples into a bioanalytical unit. This disposable PDMS microfluidic device can generate monodisperse droplets of picoliter volume directly out of a plane sidewall of the microfluidic chip by an electrohydrodynamic mechanism. The droplet generation was accomplished without using either an inserted capillary or a monolithically built-in tip. The minimum droplet volume was approximately 4 pL, and the droplet generation was repeatable and stable for at least 30 min, with a typical variation of less than 2.0% of drop size. The Taylor cone, which is usually observed in electrospray, was suppressed by controlling the surface wetting property of the PDMS device as well as the surface tension of the sample liquids. A modification of the channel geometry right before the opening of the microchannel also enhanced the continuous droplet generation without applying any external pumping. A simple numerical simulation of the droplet generation verified the importance of controlling the surface wetting conditions for the droplet formation. Our microdroplet generator can be effectively applied to a direct interface of a microfluidic chip to a biosensing unit, such as AMS, MALDI-MS or protein microarray-type biochips.

Chemical Phenomena↗

Measurements of surface tension of organic solvents using a simple microfabricated chip.

Measurement of the surface tension of organic solvents using a simple microfabricated chip was developed based on the principle of differential capillary rise. The theory, design, fabrication, and characterization of the chip were described. A two-step etching technique was used to fabricate a number of microchannels with different dimensions on the glass substrate. Capillarity was used to introduce liquid samples, which requires no power supply or actuator to be applied in the experiment. Liquid in different microchannels generated capillary rise with different heights, by which surface tension maybe calculated. Seven common organic solvents, ethanol, acetone, acetonitrile, dichloromethane, hexane, methanol, and toluene, were tested at room temperature. The surface tension of ethanol at different temperatures was measured over the range of 5-45 degrees C. Relative standard deviation for seven replicate measurements at each temperature is 0.20-0.74%. The results showed good reproducibility and acceptable precision compared with traditional methods. Very low reagent consumptions and short analysis time were achieved using this simple method.

Acetone↗

A strategy for annotating the human milk glycome.

Oligosaccharides in human milk represent a group of bioactive molecules that have evolved to be an abundant and diverse component of human milk, even though they have no direct nutritive value to the infant. A recent hypothesis proposes that they could be substrates for the development of the intestinal microflora and the mucosal immune system. The inability to determine the exact composition of these oligosaccharides limits research and the ability to understand their biological functions. Oligosaccharides isolated from the lipids and proteins of individual human milk samples were analyzed by a combination of techniques including microchip liquid chromatography mass spectrometry (HPLC-Chip/MS) and matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FT ICR MS). Accurate mass measurements obtained using an orthogonal time-of-flight (o-TOF) mass spectrometry provided oligosaccharide composition for approximately 200 individual molecular species. Comparison of HPLC-Chip/MS profiles from five different women revealed variations in milk oligosaccharide compositions. HPLC-Chip/MS profiling provides a method for routinely identifying milk oligosaccharides. Tandem MS in combination with exoglycosidase digestion provides unambiguous differentiation of structural isomers.

Chromatography, High Pressure Liquid↗

Evaporation-induced particle microseparations inside droplets floating on a chip.

We describe phenomena of colloidal particle transport and separation inside single microdroplets of water floating on the surface of dense fluorinated oil. The experiments were performed on microfluidic chips, where single droplets were manipulated with alternating electric fields applied to arrays of electrodes below the oil. The particles suspended in the droplets were collected in their top region during the evaporation process. Experimental results and numerical simulations show that this microsepration occurs as a result of a series of processes driven by mass and heat transfer. An interfacial tension gradient develops on the surface of the droplet as a result of the nonuniform temperature distribution during the evaporation. This gradient generates an internal convective Marangoni flow. The colloidal particles transported by the flow are collected in the top of the droplets by the hydrodynamic flux, compensating for evaporation through the exposed top surface. The internal flow pattern and temperature distribution within evaporating droplets were simulated using finite element calculations. The results of the simulation were consistent with experiments using tracer particles. Such microseparation processes can be used for on-chip synthesis of advanced particles and innovative microbioassays.

Colloids↗

Actin filament guidance on a chip: toward high-throughput assays and lab-on-a-chip applications.

Biological molecular motors that are constrained so that function is effectively limited to predefined nanosized tracks may be used as molecular shuttles in nanotechnological applications. For these applications and in high-throughput functional assays (e.g., drug screening), it is important that the motors propel their cytoskeletal filaments unidirectionally along the tracks with a minimal number of escape events. We here analyze the requirements for achieving this for actin filaments that are propelled by myosin II motor fragments (heavy meromyosin; HMM). First, we tested the guidance of HMM-propelled actin filaments along chemically defined borders. Here, trimethylchlorosilane (TMCS)-derivatized areas with high-quality HMM function were surrounded by SiO(2) domains where HMM did not bind actin. Guidance along the TMCS-SiO(2) border was almost 100% for filament approach angles between 0 and 20 degrees but only about 10% at approach angles near 90 degrees . A model (Clemmens, J.; Hess, H.; Lipscomb, R.; Hanein, Y.; Bohringer, K. F.; Matzke, C. M.; Bachand, G. D.; Bunker, B. C.; Vogel, V. Langmuir 2003, 19, 10967-10974) accounted for essential aspects of the data and also correctly predicted a more efficient guidance of actin filaments than previously shown for kinesin-propelled microtubules. Despite the efficient guidance at low approach angles, nanosized (<700 nm wide) TMCS tracks surrounded by SiO(2) were not effective in guiding actin filaments. Neither was there complete guidance along nanosized tracks that were surrounded by topographical barriers (walls and roof partially covering the track) unless there was also chemically based selectivity between the tracks and surroundings. In the latter case, with dually defined tracks, there was close to 100% guidance. A combined experimental and theoretical analysis, using tracks of the latter type, suggested that a track width of less than about 200-300 nm is sufficient at a high HMM surface density to achieve unidirectional sliding of actin filaments. In accord with these results, we demonstrate the long-term trapping of actin filaments on a closed-loop track (width < 250 nm). The results are discussed in relation to lab-on-a-chip applications and nanotechnology-assisted assays of actomyosin function.

Actin Cytoskeleton↗

Size sorting of protein assemblies using polymeric gradient surfaces.

We report on a novel approach for the size-dependent fractionation of protein assemblies on polymeric surfaces. Using a simple temperature gradient method to generate one-dimensional gradients of grafted poly(ethylene glycol), we fabricated silicon-oxide chips with a gradually changing surface density of kinesin motor molecules. We demonstrate that such a bioactive surface can be used to sort gliding microtubules according to their length. To our knowledge, this is the first example of the self-organized sorting of protein assemblies on surfaces.

Chemical Fractionation↗

pH-controlled diffusion of proteins with different pI values across a nanochannel on a chip.

Electrostatic interactions dominate the diffusion of proteins in a nanochannel, which was measured and modeled for pH values above and below the isoelectric points of three lectin proteins. Maximal diffusion coefficients were obtained when the proteins were neutral at their pI. This pH-controlled transport led to a separation of biomolecules across the nanochannel. A pI shift was observed, due to reversible adsorption of proteins on the walls, which affects the pH in the nanochannel.

Diffusion↗

Nano fountain pen manufacture of polymer lenses for nano-biochip applications.

Polymer microlenses have been manufactured by delivering droplets of a monomer mixture to a glass substrate using a nano fountain pen (NFP). Subsequent UV polymerization yielded microlenses with optical properties that were controlled by varying the deposition time of the monomer solution. Using this approach, it is possible to strategically place single microlenses at predefined positions with very high accuracy, an ability which may prove very useful for nano-biochip applications, as demonstrated.

Biological Assay↗

Proteomic profiling of erythrocyte proteins by proteolytic digestion chip and identification using two-dimensional electrospray ionization tandem mass spectrometry.

Self-assembled monolayers (SAMs) on coinage metal provide versatile modeling systems for studies of interfacial electron transfer, biological interactions, molecular recognition, and other interfacial phenomena. The bonding of enzyme to SAMs of alkanethiols onto gold surfaces is exploited to produce an enzyme chip. In this work, the attachment of trypsin to a SAMs surface of 11-mercaptoundecanoic acid was achieved using water soluble N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide hydrochloride and N-hydroxysuccinimide as coupling agent. A two-dimensional liquid-phase separation scheme coupled with mass spectrometry is presented for proteomic analysis of erythrocyte proteins. The application of proteomics, particularly with reference to analysis of proteins, will be described. Surface analyses have revealed that the X-ray Photoelectron Spectroscopy (XPS) C1s and N1s core levels illustrate the immobilization of trypsin. These data are also in good agreement with Fourier Transformed Infrared Reflection-Attenuated Total Reflection (FTIR-ATR) spectra for the peaks at Amide I and Amide II. Using two-dimensional nano-high performance liquid chromatography electrospray ionization tandem mass spectrometry (2D nano-HPLC-ESI-MS/MS) system observations, analytical results have demonstrated the erythrocyte proteins digestion of the immobilized trypsin on the functionalized SAMs surface. For such surfaces, it also shows the enzyme digestion ability of the immobilized trypsin. The experiment results revealed the identification of 272 proteins from erythrocyte protein sample. The terminal groups of the SAMs structure can be further functionalized with biomolecules or antibodies to develop surface-base diagnostics, biosensors, or biomaterials.

Adult↗

Label free colorimetric biosensing using nanoparticles.

In this review article, we discuss a class of biosensors that exploit the change in the colorimetric properties of noble metal nanoparticles in response to biomolecular binding at their surface. Several sensor fabrication techniques as well as sensor configurations are discussed with an emphasis on their strengths and limitations. We conclude by presenting the future prospects and challenges for the successful transition of this technology from the laboratory to a commercial product.

Algorithms↗

[Nanotechnology in medicine].

In the past, micro and nano technology were expected to have a considerable meaning for industry and especially for life sciences. The media were prodigal with visions of a tremendous rise of the life span and an enormous amelioration of life quality due to micro and nano submarines in the body and due to novel implants. In spite of these, developments in these disciplines proved to be by far more difficult and therefore lengthy in practice than expected. It is therefore necessary to verify realistically how such high technologies may support medicine. In this article, realised works are treated and new research works presented. Developments in endoscopy, novel materials und the lab on chip reached a sophisticated state of development and are therefore to be included in clinical practice for the future.

Forecasting↗