Sonography of polyethylene liners used in total knee arthroplasty.

OBJECTIVE: We investigated the ability of sonography to reveal the polyethylene liner used in total knee arthroplasty with the hopes of establishing a possible relationship between the sonographic measurement of the actual thickness of the polyethylene liner and the estimated thickness based on conventional radiography. MATERIALS AND METHODS: Twenty-four consecutive patients who were referred for Doppler screening for deep venous thrombosis after total knee arthroplasty were evaluated. The polyethylene liner was identified on sonography, and three measurements were obtained from four locations: anteromedial joint line (just medial to the midline incision), along the medial joint line, anterolateral joint line (just lateral to the midline incision), and along the lateral joint line. These sonographic measurements were compared with radiographic measurements of the radiolucent polyethylene liner and with the manufacturers' stated size of the polyethylene liner. Linear regression analyses were then performed. RESULTS: The polyethylene liner is seen on sonography as a strong linear echogenic interface with posterior acoustic shadowing. Linear regression analyses showed a high correlation (r = 0.8) between the sonographic measurements and the radiographic measurements. A relatively poor correlation (r = 0.2) was noted between the manufacturers' stated size of the liner and the sonographic measurements. CONCLUSION: We found that the polyethylene liner used in total knee arthroplasty can be clearly identified during sonographic evaluation of the knee. We also found a high correlation between the longitudinal measurement of the polyethylene liner with the thickness of the radiolucent polyethylene as measured on conventional radiographs. We propose that sonography could potentially be a useful noninvasive imaging modality to screen for subtle cases of polyethylene wear.

Aged↗

An in vitro evaluation of fluoxetine adsorption by activated charcoal and desorption upon addition of polyethylene glycol-electrolyte lavage solution.

BACKGROUND: In drug overdoses, treatment with activated charcoal is frequently used because of its adsorptive properties. Recently, whole-bowel irrigation with polyethylene glycol-electrolyte lavage solution has been used as a gastrointestinal decontamination procedure for ingestions of toxins not well adsorbed to activated charcoal and for toxins with a delayed absorption phase, although well adsorbed to activated charcoal. While a combined approach using activated charcoal and whole-bowel irrigation could theoretically enhance the efficacy of both modalities, this improvement remains speculative, since data demonstrating its clinical advantage in overdose treatment are lacking. Fluoxetine, a selective serotonin uptake inhibitor, is one of the most frequently prescribed antidepressants. Fluoxetine is well adsorbed onto activated charcoal. This in vitro investigation was undertaken to study: a) the effect of polyethylene glycol, as well as polyethylene glycol-electrolyte lavage solution, on the adsorption of fluoxetine to laboratory grade-activated charcoal and a commercial activated charcoal formulation (Carbomix powder) in simulated gastric (pH= 1.2) and intestinal (pH=7.2) fluid environment; b) whether the order of polyethylene glycol-electrolyte lavage solution addition would have any effect on the adsorption of fluoxetine to activated charcoal. METHODS: Adsorption of fluoxetine to charcoal in the presence of polyethylene glycol was examined: a) by the simultaneous addition of polyethylene glycol and charcoal to fluoxetine solution and b) by the addition of charcoal to fluoxetine solution and subsequent addition of polyethylene glycol. In both cases, the slurries were incubated at 37 degrees C for 1 hour and filtered. Free fluoxetine concentration was determined in the diluted filtrate by a reversed-phase high-performance liquid chromatography method. RESULTS: The amount of fluoxetine adsorbed to activated charcoal (or Carbomix) was dramatically decreased at gastric and intestinal pH by the presence of polyethylene glycol or polyethylene glycol-electrolyte lavage solution added either concurrently or sequentially to activated charcoal. CONCLUSIONS: In cases of fluoxetine overdose, administration of activated charcoal is recommended, while a combined approach using activated charcoal and whole-bowel irrigation with polyethylene glycol-electrolyte lavage solution is not recommended since it causes a significant desorption of the drug from activated charcoal.

Adsorption↗

The arthroscopic evaluation and characteristics of severe polyethylene wear in total knee arthroplasty.

Four hundred eighty-seven porous-coated anatomic (PCA) total arthroplasties were performed by the same surgeon between January 1982 and December 1989. Forty-three patients developed an effusion, pain, or decreased range of motion after a period of pain-free function. Average time to onset of symptoms was 4.5 years. Joint fluid aspirations were sterile and revealed the presence of high-density polyethylene crystals, best seen under a polarizing microscope. Thirty-three of these patients were arthroscopically evaluated. Extensive polyethylene wear and delamination were identified. Wear was most extensive on the medial tibial plateau. Patellar polyethylene wear was also identified. Substantial femoral component abrasions were present in areas where exposure of the tibial and patellar base plates had occurred. Diffuse granulomatous synovial tissue revealed an extensive foreign-body giant-cell reaction to polyethylene particles. In all patients, temporary symptomatic relief was obtained after arthroscopy. Thirty-two patients have, subsequently, had revision surgery. Intraoperative findings and biopsies at the time of revision confirmed the arthroscopic observations. Arthroscopy allowed the accurate diagnosis of polyethylene wear, provided temporary symptomatic relief, and facilitated preoperative revision planning. Polyethylene wear in PCA total knee replacements was related to patient characteristics (larger, younger, more active patients), nonconforming femotibial articular surfaces, thin polyethylene, heat-pressed polyethylene, and nonrigid mechanical attachment of polyethylene to metal base plate. Younger, more active, larger patients with total knee arthroplasties should be observed closely for evidence of polyethylene wear.

Aged↗

Catastrophic wear of tibial polyethylene inserts.

A number of factors play an important role in the wear-resistance of tibial polyethylene inserts. Among these are manufacturing processes that adversely affect the wear-resistance of polyethylene (such as heat treatments to the articular surface or gamma irradiation used for sterilization), tibio-femoral articular geometry, polyethylene thickness, knee alignment, femoral-component-bearing surface material, modularity of the tibial inserts and tibial trays, and quality of the polyethylene itself. The authors report an unusually high rate of failure by wear of tibial polyethylene inserts from a series of 176 Porous Coated Anatomic (PCA) knees in which there were eight revisions (4.5% of the series) performed for tibial polyethylene wear at an average of 60 months. Nine additional knees (5.1%) had thinning of greater than 30% of the initial polyethylene thickness. Four of the unsuccessful knees revealed areas of osteolysis filled with membranes containing large amounts of particulate polyethylene. In addition to the 176 knees from a series from a Los Angeles university, the cases of five other knees in four patients who came for treatment from outside hospitals with full-thickness wear of the tibial polyethylene are discussed. One of these five knees was a cementless PCA knee that developed massive osteolysis in response to the particulate polyethylene debris.

Chromium Alloys↗

The effect of molecular size, concentration in nutrient solution, and exposure time on the amount and distribution of polyethylene glycol in pepper plants.

Pepper plants Capsicum annuum L. var. California Wonder were grown in nutrient solutions of either -3.0 or -5.0 bars osmotic potential, using polyethylene glycol with molecular weights of 400, 600, 1000, 1540, or 4000 as osmotica. Polyethylene glycol with molecular weights of 1000 or 1540 proved most satisfactory as osmotica to decrease the water potential of nutrient solutions.There was no relationship between the small amount of polyethylene glycol accumulated in the plants and the amount of water transpired. The concentration of polyethylene glycol in the expressed sap of the leaves and the total accumulated was inversely related to molecular weight of polyethylene glycol, was greater at lower osmotic potential of nutrient solution, and increased with time in solution. Except for plants grown in polyethylene glycol 4000, there was more polyethylene glycol in leaves than roots. The indications were that, when the concentration of polyethylene glycol reached a value of 1 to 2 mg per ml, any additional quantity absorbed was transferred to the leaves. The major proportion of polyethylene glycol 4000 absorbed was retained in the roots.The results of Sephadex gel chromatographs showed that the passage of polyethylene glycol through the plants did not alter the average molecular weight. This indicated that there was no selective absorption of small molecules that might be present as contaminates in the commercial product.

Journal Article↗

Polyethylene transformation by a psychrotolerant Rhodococcus strain assessed by transcriptomics and 13C-isotope tracing.

Polyethylene is increasingly accumulating in nature, including remote places like the Arctic. While abiotic processes fragment polyethylene in situ, biotic transformation by microorganisms is assumed to occur. However, the enzymes and pathways involved remain poorly characterized. In this study, we used an in-house biobank from cold environments to screen for potential bacteria capable of degrading polyethylene by screening the strains in silico using the database PlasticDB and in vivo using a fluorescence-based assay. Using transcriptomic and proteomic analyses to identify genes in promising candidate strains that encode extracellular enzymes potentially capable of degrading PE, we selected a Rhodococcus erythropolis strain and two of its enzymes: a hypothetical protein (Hypr1) and a lipase family protein (Lip2). Expressing the candidate genes heterologously in Escherichia coli resulted in positive results in the fluorescence-based assay for polyethylene transformation. Applying 13C-labelled polyethylene for assessing and estimating polyethylene transformation and carbon assimilation, we found that R. erythropolis and both untransformed and recombinant E. coli extracellularly transformed the initially added polyethylene after 70 days. In addition, untransformed E. coli and R. erythropolis converted small, but significant amounts of polyethylene-derived carbon to carbon dioxide. The 13C-label was also traced into the bacterial biomass of R. erythropolis. Overall, our results provide evidence for biotic transformation of untreated polyethylene and suggests a hypothetical protein and a lipase family protein as two novel enzyme candidates associated with PE transformation.

Rhodococcus↗

Time- and depth-dependent changes in crosslinking and oxidation of shelf-aged polyethylene acetabular liners.

Since crosslinking and oxidation of ultrahigh-molecular-weight polyethylene (UHMWPE) have important roles in determining the wear resistance of UHMWPE total joint components, the time and depth dependence of crosslinking and oxidation of new shelf-aged (2-11 years), ready-to-implant acetabular liners were studied by using solvent extraction and Fourier transform infrared spectroscopy. The ultrastructure of these materials also was examined by using low-voltage scanning electron microscopy in an oil-free vacuum. Oxidation levels increased with time and with depth (p < 0.0001) from the surface of the older liners to a maximum value at about 1-2 mm below the surface, then decreased. They were minimal at the midsection of the liners. The crosslinking of these liners decreased with time and depth (p < 0.0001) and was inversely proportional to the level of oxidation. High and depth-dependent oxidation levels were observed in all older liners made from GUR 415 and 412 resins but were distinctly absent from a comparably aged (i.e., 9 years) liner made from 1900 CM-resin. Some liners showed varying degrees of inhomogeneous and discontinuous morphologic ultrastructure in addition to varying amounts of porosity while others had a more homogeneous ultrastructure. Oxidation and crosslinking of polyethylene are time- and depth-dependent processes that are mutually competitive. We suggest that resin choice and perhaps consolidation-related variables lead to differences in polyethylene's ultrastructure. These ultrastructural differences in polyethylene's inhomogeneities, that is, the type (interconnected or closed-cell) or extent may affect the oxidation resistance of polyethylene. While oxygen diffusion to free radicals in polyethylene already is known to explain some of these time- and depth-dependent effects, perhaps such ultrastructural variations also may facilitate or retard oxygen diffusion in this material. Resin-based ultrastructural variability partially may explain the variability in the clinical performance of polyethylene total joint implant components. Thus resin choice or processing modifications related to polyethylene's ultrastructure may increase its oxidation resistance and ultimately improve the clinical wear performance of polyethylene total joint orthopedic implants.

Acetabulum↗

Contact stress assessment of conventional and highly crosslinked ultra high molecular weight polyethylene acetabular liners with finite element analysis and pressure sensitive film.

Stress magnitude and distribution of both conventional polyethylene versus a crosslinked polyethylene in the liner of a total hip replacement (THR) were examined using finite element analysis and pressure sensitive film. Both types of polyethylene were assessed against head sizes of 22 and 28 mm with 5-mm thick polyethylene liners and head sizes of 28, 38, and 46 mm with 3-mm thick polyethylene liners. Liners with 5-mm conventional polyethylene represented successful combinations with long track records. Our hypothesis was that although the combination of the large head and the lower modulus of the highly crosslinked polyethylene would lead to lower stresses, the stresses would be excessive if the liner was extremely thin at 3 mm. Von Mises stresses at the articulating surface of the highly crosslinked liners were lower, when compared to conventional polyethylene, in every THR size examined. Specifically, however, the 38- and 46-mm inner diameter (ID) highly crosslinked polyethylene even at the extreme of only 3-mm thick had lower stresses than the 22-mm ID conventional liner of 5-mm thickness. These data indicate that the use of a large head against highly crosslinked material even at 3-mm thickness results in lower stresses than in an existing conventional 22-mm head and 5-mm thick combination. Obviously, other considerations will influence the minimum thickness to be recommended.

Acetabulum↗

Colonization, biofilm formation and biodegradation of polyethylene by a strain of Rhodococcus ruber.

A two-step enrichment procedure led to the isolation of a strain of Rhodococcus ruber (C208) that utilized polyethylene films as sole carbon source. In liquid culture, C208 formed a biofilm on the polyethylene surface and degraded up to 8% (gravimetrically) of the polyolefin within 30 days of incubation. The bacterial adhesion to hydrocarbon assay and the salt aggregation test both showed that the cell-surface hydrophobicity of C208 was higher than that of three other isolates which were obtained from the same consortium but were less efficient than C208 in the degradation of polyethylene. Mineral oil, but not nonionic surfactants, enhanced the colonization of polyethylene and increased biodegradation by about 50%. Fluorescein diacetate (FDA) hydrolysis and protein content analysis were used to test the viability and biomass density of the C208 biofilm on the polyethylene, respectively. Both FDA activity and protein content of the biofilm in a medium containing mineral oil peaked 48-72 h after inoculation and then decreased sharply. This finding apparently reflected rapid utilization of the mineral oil adhering to the polyethylene. The remaining biofilm population continued to proliferate moderately and presumably played a major role in biodegradation of the polyethylene. Fourier transform infrared spectra of UV-photooxidized polyethylene incubated with C208 indicated that biodegradation was initiated by utilization of the carbonyl residues formed in the photooxidized polyethylene.

Biodegradation, Environmental↗

[Mechanisms of damage to metal-on-polyethylene articulating surfaces of total hip prostheses: influence of intra-articulate migration of metallic debris].

PURPOSE OF THE STUDY: The objective of this work was to identify the mechanisms leading to deterioration of the polyethylene acetabular surface in total hip prostheses. MATERIAL AND METHODS: We conducted an in vivo analysis of damage caused to articulating surfaces of metal-on-polyethylene total hip prostheses. This analysis was performed on three of the 45 explants of Harris-Galante prostheses available to use from our series of 1480 implantations performed between 1985 and 1996. These three pieces were selected because large-sized fibers of metallic debris were identified on the polyethylene surface and because the explants had been performed for reasons other than loosening in aseptic patients. Macroscopic examination was combined with scan electron microscopy to analyze morphological changes. RESULTS: We found that identical damage could be observed on the polyethylene explants despite the different sizes of the metallic heads and different metal-on-polyethylene combinations. Our analysis confirmed the deleterious effect of metallic foreign bodies trapped in contact with the articulate surfaces. These foreign bodies resulted in one case from rupture of a multifilament wire used for the trochanteric fixation and in two cases from the surfacing of the non-cemented Harris-Galante cups. The microscopic analysis demonstrated several successive localizations of the foreign bodies on the polyethylene surface before becoming deeply encrusted in the polyethylene where they deteriorated the femoral head surface (rough) and wore the polyethylene surface (abrasion). When the fibers came from the surfacing of the Harris-Galante cups, the metallic debris remained unrecognized during the revision procedure and were only identified later during the systematic examination of prosthetic explants. DISCUSSION AND CONCLUSION: These findings emphasize the importance of quality surface treatments for non-cemented prostheses and argue in favor of particular precautions during operative manipulation of these components. A systematic analysis of the prosthetic explants is advisable, particularly for components explanted because of wear or unexplained osteolysis. Use of multifilament trochanteric wires should be avoided because rupture raises the risk of intra-articulate migration of metallic debris. If the prosthesis involves a polyethylene acetabular surface, ceramic heads should be preferred to improve resistance to abrasion, particularly to limit the deleterious effect of a third body.

Adult↗

Wear of the polyethylene liner-metallic shell interface in modular acetabular components. An in vitro analysis.

The purpose of this study was to determine the effect of compression cycles and wear patterns on the polyethylene liner-metallic shell interface in modular acetabular components. Articular frictional torque was also measured. Modular acetabular components from five manufacturers were tested. The polyethylene liners were sputter coated with gold on the convex surface to enhance the visualization of wear and deformation patterns. Each component was cycled for 10 million cycles in a hydraulic fatigue testing machine. Frictional torque was measured prior to the start of the cyclic loading and in increments of 2 million cycles. Frictional torque was significantly lower in the design with an enhanced polyethylene liner. Abrasion of the gold from the convex surface of polyethylene liners varied from 2 to 23% between designs. Extrusion of the polyethylene into the screw holes in the metallic shells was universal. Three modes of damage (burnishing, punch-out, and gouging) were identified on the convex surface of the polyethylene liner. Abrasion of the gold from the convex surface of the polyethylene varied greatly between designs. This is indicative of relative motion between the polyethylene liner and the metallic shell. This motion must be minimized to limit the generation of wear debris from the convex surface of the polyethylene. Several aspects of modular acetabular component design could be implemented to potentially reduce wear, including limiting the number of holes available for screw placement, smoothing out the edges of the screw holes to avoid punch-out, and avoiding supplemental fixation of the liner unless it is essential to prevent motion between the liner and the metallic shell.

Analysis of Variance↗

Comparison of the polyethylene glycol antiglobulin test and the use of enzymes in antibody detection and identification.

BACKGROUND: The polyethylene glycol indirect antiglobulin test for detection of red cell antibodies was compared with a proven, highly sensitive test system using papain. STUDY DESIGN AND METHODS: Parallel, prospective testing of 1508 samples with polyethylene glycol and with albumin and papain evaluated the sensitivity and specificity of polyethylene glycol. Retrospective analysis of antibody specificities was performed for the 2 years before and the 2 years after the institution of polyethylene glycol testing. RESULTS: Of 1508 prospective screens, 53 (3.5%) had discordant results: 5 were positive only in polyethylene glycol and 48 were positive only in albumin and papain. Upon antibody identification, the 5 samples that were positive only in polyethylene glycol showed 1 anti-D, 2 warm autoantibodies, and 2 false-positive results. The 48 samples that were positive only in albumin and papain showed 1 each of the following: anti-Le(b); anti-P1; anti-S; high-titer, low-avidity antibody; and cold autoantibody; there were 43 false-positive results. False-positive results totaled 12 (0.8%) with polyethylene glycol and 53 (3.5%) with albumin and papain. The retrospective analysis of antibody specificity with polyethylene glycol showed a significant increase in the detection of Fy(a) and/or Fy(b) (p < 0.0002) and Jk(b) (p < 0.0002) antibodies and a decrease in the detection of Le(a) and/or Le(b) antibodies (p < 0.0002). CONCLUSION: Polyethylene glycol retained the high sensitivity of the albumin and papain, while significantly lowering the number of false-positive results and decreasing the detection of antibodies of doubtful clinical significance.

Antibody Specificity↗

Cemented polyethylene versus uncemented metal-backed glenoid components in total shoulder arthroplasty: a prospective, double-blind, randomized study.

Thirty-nine patients (forty shoulders) with primary osteoarthritis consented to be randomized to receive either a cemented all-polyethylene glenoid component or a cementless metal-backed component at the time of total shoulder arthroplasty. Their mean age was 69 years. Preoperative and postoperative evaluations were completed at 3, 6, 12, 24, and 36 months by history, physical examination, radiographs, and Constant scoring system. The presence of periprosthetic radiolucent lines was significantly greater with polyethylene than with metal-backed glenoids (85% vs 25%, P <.01). Of 20 radiolucent lines, 12 (60%) around polyethylene glenoids were present on immediate postoperative radiographs and 25% were progressive. No significant correlation was found between the presence of radiolucent lines around polyethylene glenoids and functional results (P =.3). By contrast, periprosthetic radiolucent lines around metal-backed glenoids were rare but progressive when present. The incidence of loosening of metal-backed implants (4 cases, 20%) was significantly higher than that observed with polyethylene glenoids (0%, P <.001) and was associated with component shift and severe osteolysis. Metal-backed glenoid loosening significantly correlated with deteriorating functional results and increasing pain (P <.05). Revision surgery was required for 4 patients in the metal-backed group (P =.02), for a subscapularis tear (1 case) and metal-backed glenoid component loosening (3 cases). Computed tomography scan analysis and revision surgery revealed that preoperative posterior humeral subluxation may recur with time despite glenoid reorientation and may cause asymmetric accelerated polyethylene wear, resulting in metal-on-metal contact and severe osteolysis. Reimplantation of a stable cemented glenoid component was possible in 1 case, whereas the cavitary defect was packed with cancellous bone in the 2 other cases. At a minimum of 3 years' follow-up, the results of this study clearly show that (1) the survival rate of cementless, metal-backed glenoid components is inferior to cemented all-polyethylene components and (2) the incidence of radiolucency at the glenoid-cement interface with all-polyethylene components is high and remains a concern. The high rate of loosening, because of the absence of ingrowth and/or the accelerated polyethylene wear, has led us to abandon the use of metal-backed glenoids. Efforts must continue to improve glenoid component design and fixation.

Aged↗

A randomized comparison of all-polyethylene and metal-backed tibial components.

Clinical failures of all-polyethylene tibial components in total knee arthroplasty generally have been failures of design, not materials. The current study was designed to compare a modern congruent all-polyethylene tibial component with a metal-backed tibial component with the same articular design and geometry. All patients older than 60 years of age requiring total knee arthroplasty were randomized prospectively to receive either a cemented posterior cruciate ligament-retaining all-polyethylene component or a metal-backed tibial component with identical articular surfaces. All patients received identical cemented femoral and all-polyethylene patellar implants. The mean age of the patients was 69 years, and the mean American Society of Anesthesiology score was 3. The diagnosis was osteoarthritis in 92% of this population. Three hundred twenty-four total knee arthroplasties in 296 patients were performed; 213 joints (111 all-polyethylene tibias and 102 metal-backed tibias) with a minimum of 3 years followup (mean, 49 months) are reported. The preoperative Knee Society knee score in the group of patients who received an all-polyethylene tibial component was 38 points, improving to 84 points at latest followup, whereas in the group of patients who received a metal-backed tibial component, the score improved from 35 to 85 points. Functional scores increased from preoperative values of 56 to 74 points in the patients who received all-polyethylene tibial components, and 57 to 72 points in the patients who received metal-backed tibial components. Range of motion measured at latest followup averaged 106 degrees in patients who received an all-polyethylene tibial component and 107 degrees in the patients who received a metal-backed component, and postoperative tibiofemoral alignment averaged 6 degrees valgus for both groups. There were 13 reoperations for instability, patellofemoral problems, or deep infection, but none for aseptic loosening or wear in either group. These differences were not statistically significant, nor were any measures of patient satisfaction or clinical outcome between the two groups in this period. Total knee arthroplasty with a well-designed, contemporary congruent all-polyethylene tibial component functions equivalently to its metal-backed tibial counterpart at 3- to 5-year followup in this patient population, and is less costly ($675).

Aged↗

Comparison of cross-linked polyethylene materials for orthopaedic applications.

Cross-linked polyethylenes are being marketed by orthopaedic manufacturers to address the problem of osteolysis caused by polyethylene particulate wear debris. Wear testing of these cross-linked polyethylenes in hip simulators has shown dramatic reduction in wear rate compared with standard ultrahigh molecular weight polyethylene, either gamma irradiated in air or nitrogen - or ethylene oxide-sterilized. However, this reduction in wear rate is not without cost. The cross-linking processes can result in materials with lower mechanical properties than standard ultrahigh molecular weight polyethylene. To evaluate the effect of the various cross-linking processes on physical and mechanical properties of ultrahigh molecular weight polyethylene, commercially available cross-linked polyethylenes from six orthopaedic manufacturers were tested. This study was the culmination of collaboration with these manufacturers, who provided cross-linked polyethylene for this study, wear characteristics of the material they provided, and review of the physical and mechanical properties measure for their polyethylene. Cross-linked materials were evaluated as received and after an accelerated aging protocol. Free radical identity and concentration, oxidation, crystallinity, melt temperature, ultimate tensile strength, elongation at break, tensile stress at yield, and toughness are reported for each material. By comparing these physical and mechanical properties, surgeons can evaluate the trade-off that results from developing materials with substantially lower wear rates.

Magnetic Resonance Spectroscopy↗

Polyethylene glycol superoxide dismutase and catalase attenuate increased blood-brain barrier permeability after ischemia in piglets.

BACKGROUND AND PURPOSE: Transport of urea across the blood-brain barrier is increased during postischemic cerebral reperfusion in the piglet. Ischemia/reperfusion also has been observed to increase apparent superoxide anion generation on the surface of the brain. The present study was designed to address the hypothesis that the increased transfer of urea into the brain after ischemia/reperfusion could be due to superoxide anion-induced alterations in blood-brain barrier permeability. METHODS: Blood-to-brain transfer of carbon-14-labeled urea was measured in four groups (n = 7 each) of newborn pigs: 1) control (no ischemia, no pretreatment), 2) pretreatment with polyethylene glycol superoxide dismutase (1,000 IU/kg) and polyethylene glycol catalase (10,000 IU/kg i.v.) but no ischemia, 3) no pretreatment and 20 minutes of ischemia followed by 2 hours of reperfusion, and 4) pretreatment with polyethylene glycol superoxide dismutase and polyethylene glycol catalase in addition to ischemia/reperfusion. The following brain regions were investigated: cerebrum, caudate, midbrain, pons, medulla, and cerebellum. RESULTS: Polyethylene glycol superoxide dismutase inhibited generation of superoxide anion by the brain during reperfusion after ischemia. Regional transfer of [14C]urea from blood to brain increased at 2 hours' reperfusion. This ischemia-induced increase in blood-to-brain transfer of [14C]urea was attenuated by pretreatment with polyethylene glycol superoxide dismutase and polyethylene glycol catalase: e.g., cerebrum Kin was 28 +/- 2 in the control group, 26 +/- 3 in the pretreated/no ischemia group, 67 +/- 5 in the untreated/ischemia group, and 40 +/- 2 ml.g-1.s-1.10(6) in the pretreated/ischemia group. After ischemia/reperfusion, cerebral blood flow was unchanged by pretreatment with polyethylene glycol superoxide dismutase and polyethylene glycol catalase. CONCLUSIONS: These data suggest that production of a partially reduced species of oxygen contributes to the increased urea transfer across the blood-brain barrier after ischemia in the newborn pig.

Animals↗

Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results.

BACKGROUND: Polyethylene wear debris, and the resulting inflammatory response leading to osteolysis and loosening, is the primary mode of failure limiting the longevity of total hip replacements. Alternative bearing surfaces, including ceramic-on-polyethylene, have been investigated in an effort to decrease the amount of polyethylene wear debris. The purpose of this study was to evaluate the seventeen to twenty-one-year results of the use of ceramic-on-polyethylene total hip prostheses. METHODS: Sixty-four total hip prostheses were implanted with cement, by one surgeon, in fifty-six patients from 1978 to 1981. The average age at the index arthroplasty was sixty-nine years (range, fifty-one to eighty-four years). The components consisted of a cemented Charnley-Müller stem with a 32-mm modular alumina femoral head and a cemented all-polyethylene acetabular component. All patients who retained the index prosthesis were assessed clinically with use of Harris hip scores and were evaluated radiographically at the time of the latest follow-up. RESULTS: At the time of this latest follow-up, of the original sixty-four implants, eighteen (28%) were still in place and five (8%) had been revised. The remaining forty-one implants were in patients who had died and were functioning well until the patient's death. No patient was lost to follow-up. Of the eighteen hips with an intact prosthesis in the surviving patients, seven had an excellent clinical result; nine, a good result; and two, a fair result. One asymptomatic hip had definite radiographic evidence of femoral loosening. No hip had definite signs of acetabular loosening or evidence of osteolysis. Survivorship analysis revealed that the probability of survival of the prostheses without revision was 95% at five years, 95% at ten years, 89% at fifteen years, and 79% at twenty years. The mean linear and volumetric polyethylene wear rates were 0.034 mm/yr and 28 mm(3)/yr, respectively. There were no fractures of the ceramic heads. CONCLUSIONS: Outstanding long-term clinical and radiographic results were attained despite the use of what are now considered substandard techniques (an inferior stem design, a 32-mm head, and first-generation cementing techniques). The wear rates in this study are lower than previously reported metal-on-polyethylene wear rates and are consistent with the lowest reported in vivo ceramic-on-polyethylene wear rates. These findings support the consideration of ceramic-on-polyethylene bearing surfaces in total hip arthroplasty.

Aged↗

A clinically practical method of manually assessing polyethylene liner thickness.

BACKGROUND: Most orthopaedists do not have access to contemporary computer-assisted radiographic techniques and therefore must use manual radiographic methods to assess polyethylene wear. The accuracy of most manual methods, however, has not been verified on clinical radiographs. In this study, we used manufacturer-developed wear templates to measure polyethylene wear and compared that technique with two other commonly used manual radiographic methods. Our purpose was to compare the accuracy of these techniques and thus determine their usefulness in assessing polyethylene wear in individual patients. METHODS: We analyzed seventeen polyethylene liners that were retrieved during revision operations after a mean of 12.0 years in situ. With use of digital calipers, we directly measured the true minimum polyethylene thickness of the explanted liner. We then measured the polyethylene thickness on anteroposterior pelvic radiographs that had been made before the revision. Three different manual techniques were used to evaluate the radiographs: the Dorr method, the Livermore method, and the newly described wear-template method. The minimum polyethylene thickness that was calculated with use of each of these methods was compared with the thickness as determined by direct measurement of the explanted liner. RESULTS: The mean error for the Dorr method (1.54 +/- 1.21 mm) was significantly greater than that for both the Livermore method (0.07 +/- 0.62 mm) and the wear-template method (-0.04 +/- 0.28 mm) (p < 0.01). The mean error for the Dorr method was significantly greater than zero (p < 0.01), indicating that this method consistently overestimated the true measurement. In contrast, the mean errors for the Livermore and wear-template methods were not significantly different from zero (p = 0.64 and 0.58, respectively), indicating that these methods did not consistently underestimate or overestimate the true measurement. However, the large standard deviations for all three methods suggest that the ranges in error are wide. The limits of agreement for the Livermore technique ranged from a 1.17-mm underestimation to a 1.31-mm overestimation of the true thickness of the polyethylene; those of the wear-template technique were smaller, ranging from a 0.60-mm underestimation to a 0.52-mm overestimation. CONCLUSION: The practicing orthopaedist needs an accurate and efficient method for determining the polyethylene thickness of modular acetabular components. We found that the template method best met this requirement because it involved a simple procedure: placing the template over the radiograph and measuring the distance between the femoral head and the inner surface of the metal shell. The other methods were less accurate, required additional information from the manufacturer, were more time-consuming, and were not as easy to demonstrate to the patient.

Acetabulum↗