PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70Linked to original sources

Microfabricated devices: A new sample introduction approach to mass spectrometry.

Instrument miniaturization is one way of addressing the issues of sensitivity, speed, throughput, and cost of analysis in DNA diagnostics, proteomics, and related biotechnology areas. Microfluidics is of special interest for handling very small sample amounts, with minimal concerns related to sample loss and cross-contamination, problems typical for standard fluidic manipulations. Furthermore, the small footprint of these microfabricated structures leads to instrument designs suitable for high-density, parallel sample processing, and high-throughput analyses. In addition to miniaturized systems designed with optical or electrochemical detection, microfluidic devices interfaced to mass spectrometry have also been demonstrated. Instruments for automated sample infusion analysis are now commercially available, and microdevices utilizing chromatographic or capillary electrophoresis separation techniques are under development. This review aims at documenting the technologies and applications of microfluidic mass spectrometry for the analysis of proteomic samples.

Biotechnology↗

Application of on-chip cell cultures for the detection of allergic response.

In this report, the development of a microfluidic cell chip for monitoring allergic response is described. A rat basophilic leukemia cell line (RBL-2H3), a tumor analog of rat mucosal mast cells, has been used as a model to observe its allergic response upon antigen stimulus. The cells were cultivated on a poly(dimethylsiloxane) (PDMS) chip, the surface of which was modified by several methods. The PDMS chip, which comprised a cell cultivation chamber and microfluidic channels, was fabricated by conventional molding methods. In order to detect the allergic response, a fluorescent dye, quinacrine, was introduced inside the cell compartment that included histamine. The cells were stimulated with dinitrophenylated bovine serum albumin (DNP-BSA) after incubation with anti-DNP IgE. When exocytosis events occurred, the microfluidic system detected the fluorescent signal of quinacrine, which was released from RBL-2H3 cells by using a photomultiplier tube (PMT) fitted onto a microscope.

Animals↗

Automatic bio-sampling chips integrated with micro-pumps and micro-valves for disease detection.

The present study reports a microfluidic system using the concept of membrane-movement to design and fabricate micro-pneumatic valves and pumps to form a bio-sensing diagnostic chip. The automatic bio-sampling system includes a micro-diagnostic chip fabricated by using MEMS (micro-electro-mechanical systems) technology and an automatic platform comprising of a control circuit, a compressed air source and several electromagnetic valve switches. The control circuit is used to regulate the electromagnetic valve switches, causing thin PDMS membranes to deflect pneumatically by the compressed air and generate valving and pumping effects. The micro-diagnostic chip allows for the quick detection of diseases. Compared to large-scale systems, the new microfluidic system uses smaller amounts of samples and reagents and performs fast diagnosis in an automated format. Instead of using traditional pneumatic micro-pumps, the current study adopts a new design called "spider-web" micro-pumps to increase the pumping rate, and more importantly, improve the uniformity of flow rates inside multiple micro-channels. Experimental data show that for disease diagnosis, the bio-sensing chips integrated with the micro-pneumatic valves and the peristaltic micro-pumps could successfully perform diagnosis tests. Small amounts of samples and reagents could be injected into the diagnosis chips using the micro-pumps and the micro-pneumatic valves could effectively control the movement of the samples and reagents. In order to demonstrate the functionality of the developed device, detection of hepatitis C virus (HCV) and syphilis has been performed using the bio-sampling chips. Experimental data show that fluorescence signals from the microfluidic system were comparable to the ones using conventional testing methods. The developed chip could be easily extended for multiple disease detection. The automatic bio-sensing chips could provide a useful tool for fast disease detection and be crucial for a micro-total-analysis system.

Biosensing Techniques↗

Plastic microchip liquid chromatography-matrix-assisted laser desorption/ionization mass spectrometry using monolithic columns.

A prototype array of monolithic liquid chromatography (LC) columns was prepared in a plastic microfluidic device for the off-line interface with matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The microfluidic channels were fabricated on a cyclic olefin copolymer (COC) plate by hot embossing. An array of methacrylate monolithic columns was prepared in the microfluidic channels by UV-initiated polymerization. The deposition system employed a pulsed electric field to transfer the effluents from multiple columns directly onto MALDI targets with a non-contact deposition method reported by Ericson et al. [C. Ericson, Q.T. Phung, D.M. Horn, E.C. Peters, J.R. Fitchett, S.B. Ficarro, A.R. Salmon, L.M. Brill, A. Brock, Anal. Chem. 75 (2003) 2309]. To characterize the off-line interface of the multiple-channel microchip LC and the MALDI-MS for the analysis of peptide mixtures, the separation efficiency and reproducibility tests in each column were carried out by separating a peptide mixture from tryptic digested proteins and depositing the multiple effluents simultaneously on the MALDI target plate. Using a MALDI-TOF mass spectrometer with a mass accuracy of +/-1 Da for peptide assignments of digested bovine serum albumin (BSA), amino acid sequence coverage of around 59% was obtained for the microchip LC-MALDI-MS compared to 23% obtained by the MALDI-MS method without LC separation. In sensitivity tests for the detection of low abundance proteins in the presence of high concentration protein mixtures, as low as 10 fmol/mul (S/N = 10) of a spiked peptide in 1 microg of digested BSA could be detected. In the analysis of a mixture of three digested proteins (BSA, myoglobin, and cytochrome c), more than twice the amino acid sequence coverage was obtained for the microchip LC-MALDI-MS compared to MALDI-MS alone.

Cytochromes c↗

Optimal configuration of capillary electrophoresis microchip with expansion chamber in separation channel.

This study develops a novel capillary electrophoresis (CE) microfluidic device featuring a conventional cross-form injection system and an expansion chamber located at the inlet of the separation channel. The combined injection system/expansion chamber arrangement is designed to deliver a high-quality sample band into the separation channel such that the detection performance of the device is enhanced. Numerical simulations are performed to investigate the electrokinetic transport processes in the microfluidic device and to establish the optimal configuration of the expansion chamber. The results indicate that an expansion chamber with an expansion ratio of 2.5 and an expansion length of 500 microm delivers a sample plug with the correct shape and orientation. With this particular configuration, the peak intensities of the sample are sharp and clearly distinguishable in the detection region of the separation channel. Therefore, this configuration is well suited for capillary electrophoresis applications which require a highly sensitive resolution of the sample plug. The novel CE microfluidic device developed in this study has an exciting potential for use in high-performance, high-throughput chemical analysis applications and in many other applications throughout the field of micro-total-analysis-systems.

Electrophoresis, Microchip↗

Integrating polymerase chain reaction, valving, and electrophoresis in a plastic device for bacterial detection.

An integrated plastic microfluidic device was designed and fabricated for bacterial detection and identification. The device, made from poly(cyclic olefin) with integrated graphite ink electrodes and photopatterned gel domains, accomplishes DNA amplification, microfluidic valving, sample injection, on-column labeling, and separation. Polymerase chain reaction (PCR) is conducted in a channel reactor containing a volume as small as 29 nL; thermal cycling utilizes screen-printed graphite ink resistors. In situ gel polymerization was employed to form local microfluidic valves that minimize convective flow of the PCR mixture into other regions. After PCR, amplicons (products) are electrokinetically injected through the gel valve, followed by on-chip electrophoretic separation. An intercalating dye is admixed to label the amplicons; they are detected using laser-induced fluorescence. Two model bacteria, Escherichia coli O157 and Salmonella typhimurium, were chosen to demonstrate bacterial detection and identification based on amplification of several of their unique DNA sequences. The limit of detection is about six copies of target DNA.

Bacteria↗

Dynamic gene expression profiling using a microfabricated living cell array.

We describe the development of a microfluidic platform for continuous monitoring of gene expression in live cells. This optically transparent microfluidic device integrates high-throughput molecular stimulation with nondestructive monitoring of expression events in individual living cells, hence, a living cell array (LCA). Several concentrations of a soluble molecular stimulus are generated in an upstream microfluidic network and used to stimulate downstream reporter cells, each containing a green fluorescence reporter plasmid for a gene of interest. Cellular fluorescence is continuously monitored and quantified to infer the expression dynamics of the gene being studied. We demonstrate this approach by profiling the activation of the transcription factor NF-kappaB in HeLa S3 cells in response to varying doses of the inflammatory cytokine TNF-alpha. The LCA platform offers a unique opportunity to simultaneously control dynamic inputs and measure dynamic outputs from adherent mammalian cells in a high-throughput fashion. This approach to profiling expression dynamics, in conjunction with complementary techniques such as DNA microarrays, will help provide a more complete picture of the dynamic cellular response to diverse soluble stimuli.

Gene Expression Profiling↗

Mixing crowded biological solutions in milliseconds.

In vitro studies of biological reactions are rarely performed in conditions that reflect their native intracellular environments where macromolecular crowding can drastically change reaction rates. Kinetics experiments require reactants to be mixed on a time scale faster than that of the reaction. Unfortunately, highly concentrated solutions of crowding agents such as bovine serum albumin and hemoglobin that are viscous and sticky are extremely difficult to mix rapidly. We demonstrate a new droplet-based microfluidic mixer that induces chaotic mixing of crowded solutions in milliseconds due to protrusions of the microchannel walls that generate oscillating interfacial shear within the droplets. Mixing in the microfluidic mixer is characterized, mechanisms underlying mixing are discussed, and evidence of biocompatibility is presented. This microfluidic platform will allow for the first kinetic studies of biological reactions with millisecond time resolution under conditions of macromolecular crowding similar to those within cells.

Biocompatible Materials↗

On-chip amperometric measurement of quantal catecholamine release using transparent indium tin oxide electrodes.

Carbon-fiber amperometry has been extensively used to monitor the time course of catecholamine release from cells as individual secretory granules discharge their contents during the process of quantal exocytosis, but microfabricated devices offer the promise of higher throughput. Here we report development of a microchip device that uses transparent indium tin oxide (ITO) electrodes to measure quantal exocytosis from cells in microfluidic channels. ITO films on a glass substrate were patterned as 20-mum-wide stripes using photolithography and wet etching and then coated with polylysine to facilitate cell adherence. Microfluidic channels (100 mum wide by 100 mum deep) were formed by molding poly(dimethylsiloxane) (PDMS) on photoresist and then reversibly sealing the PDMS slab to the ITO-glass substrate. Bovine adrenal chromaffin cells were loaded into the microfluidic channel and adhered to the ITO electrodes. Cells were stimulated to secrete by perfusing a depolarizing "high-K" solution while monitoring oxidation of catecholamines on the ITO electrode beneath the cell using amperometry. Amperometric spikes with charges ranging from 0.1 to 1.5 pC were recorded with a signal-to-noise ratio comparable to that of carbon-fiber electrodes. Further development of this approach will enable high-throughput measurement of quantal catecholamine release simultaneously with optical cell measurements such as fluorescence.

Adrenal Glands↗

Chip-based polyketide biosynthesis and functionalization.

We demonstrate construction and novel compound synthesis from a synthetic metabolic pathway consisting of a type III polyketide synthase (PKS) known as 1,3,6,8-tetrahydroxynaphthalene synthase (THNS) from Streptomyces coelicolor and soybean peroxidase (SBP) in a microfluidic platform. THNS immobilized to Ni-NTA agarose beads is prepacked into a microfluidic channel, while SBP is covalently attached to the walls of a second microfluidic channel precoated with a reactive poly(maleic anhydride) derivative. The result is a tandem, two-step biochip that enables the synthesis of novel polyketide derivatives. The first microchannel, consisting of THNS, results in the conversion of malonyl-CoA to flaviolin in yields up to 40% with a residence time of 6 min. This conversion is similar to that obtained in several-milliliter batch reactions after 2 h. Linking this microchannel to the SBP microchannel results in biflaviolin synthesis. During the course of this work, we discovered that the substrate specificity of THNS could be manipulated by simply changing the reaction pH. As a result, the starter acyl-CoA specificity can be broadened to yield a series of truncated pyrone products. When combined with variations in the ratio of acyl-CoA and malonyl-CoA (extender substrate) feed rates, high yields of the pyrone products could be achieved, which is further structurally diversified from self- and cross-coupling in the SBP microchannel. The ability to rapidly evaluate the effects of reaction conditions and synthetic multienzyme pathways on a microfludic platform provides a new paradigm for performing metabolic pathway engineering, namely, the reconstruction of pathways for use in new compound discovery.

Catalysis↗

Multitechnique characterization of fatty acid-modified microgels.

The structure of fatty acid-modified hydrogel objects (microgels) created within microfluidic devices for controlled-release or sensory applications was characterized by various imaging and spectroscopic methods. Imaging with scanning electron microscopy revealed that the surface was rough and irregular on the micrometer scale. Examination of planar model systems analogous to the modified microgels with X-ray photoelectron spectroscopy and secondary ion mass spectroscopy showed that a fatty acid coating formed when the reaction conditions were conducive to covalent-bond formation. Visualization of the selectively stained lipophilic coating with laser scanning confocal microscopy while the microgel was positioned within a microfluidic channel demonstrated that the coating was confined to the microgel's periphery. Finally, using transmission electron microscopy, the thickness of the region functionalized with fatty acids was determined to be around 9 microm on samples very similar to those integrated into microfluidic devices. By using transmission electron microscopy to monitor the thickness of the fatty acid coating produced with different reaction conditions, it may be possible to customize these hybrid materials for specific sensory or controlled-release applications.

Apatites↗

A novel single-step fabrication technique to create heterogeneous poly(ethylene glycol) hydrogel microstructures containing multiple phenotypes of mammalian cells.

In this study, a novel method for the one-step fabrication of stacked hydrogel microstructures using a microfluidic mold is presented. The fabrication of these structures takes advantage of the laminar flow regime in microfluidic devices, limiting the mixing of polymer precursor solutions. To create multilayered hydrogel structures, microfluidic devices were rotated 90 degrees from the traditional xy axes and sealed with a cover slip. Two discreet fluidic regions form in the channels, resulting in the multilayered hydrogel upon UV polymerization. Multilayered patterned poly(ethylene glycol) hydrogel arrays (60 mum tall, 250 mum wide) containing fluorescent dyes, fluorescein isothiocyanate, and tetramethylrhodamine isothiocyanate were created for imaging purposes. Additionally, this method was used to generate hydrogel layers containing murine fibroblasts and macrophages. The cell adhesion promoter, RGD, was added to hydrogel precursor solution to enhance fibroblast cell spreading within the hydrogel matrix in one layer, but not the other. We were able to successfully generate patterns of hydrogels containing multiple phenotypes by using this technique.

Animals↗

A method for dynamic system characterization using hydraulic series resistance.

The pressure required to drive flow through a microfluidic device is an important characteristic of that device. We present a method to measure the flow rate through microfluidic components and systems, including micropumps and microvalves. The measurement platform is composed of two pressure sensors and a glass tube, which provides series resistance. The principle of the measurement is the fluid dynamical equivalent of Ohm's law, which defines the relationship between current, resistance, and voltage that are analogues to flow rate, hydraulic resistance, and pressure drop, respectively. Once the series resistance is known, it is possible to compute the flow rate through a device based on pressure alone. In addition, the dynamic system characteristics of the device-resistance and capacitance-can be computed. The benefits of this method are its simple configuration, capability of measuring flow rate accurately from the more easily measured pressure, and the ability to predict the dynamic response of microfluidic devices.

Microfluidic Analytical Techniques↗

Single DNA molecule stretching in sudden mixed shear and elongational microflows.

High-throughput stretching and monitoring of single DNA molecules in continuous elongational flow offers compelling advantages for biotechnology applications such as DNA mapping. However, the polymer dynamics in common microfluidic implementations are typically complicated by shear interactions. These effects were investigated by observation of fluorescently labeled 185 kb bacterial artificial chromosomes in sudden mixed shear and elongational microflows generated in funneled microfluidic channels. The extension of individual free DNA molecules was studied as a function of accumulated fluid strain and strain rate. Under constant or gradually changing strain rate conditions, stretching by the sudden elongational component proceeded as previously described for an ideal elongational flow (T. T. Perkins, D. E. Smith and S. Chu, Science, 1997, 276, 2016): first, increased accumulated fluid strain and increased strain rate produced higher stretching efficiencies, despite the complications of shear interactions; and second, the results were consistent with unstretched molecules predominantly in hairpin conformations. More abrupt strain rate profiles did not deliver a uniform population of highly extended molecules, highlighting the importance of balance between shear and elongational components in the microfluidic environment for DNA stretching applications. DNA sizing with up to 10% resolution was demonstrated. Overall, the device delivered 1000 stretched DNA molecules per minute in a method compatible with diffraction-limited optical sequence motif mapping and without requiring laborious chemical modifications of the DNA or the chip surface. Thus, the method is especially well suited for genetic characterization of DNA mixtures such as in pathogen fingerprinting amidst high levels of background DNA.

Bacteriophage lambda↗

Proteome-on-a-chip: mirage, or on the horizon?

Proteomics has emerged as the next great scientific challenge in the post-genome era. But even the most basic form of proteomics, proteome profiling, i.e., identifying all of the proteins expressed in a given sample, has proven to be a demanding task. The proteome presents unique analytical challenges, including significant molecular diversity, an extremely wide concentration range, and a tendency to adsorb to solid surfaces. Microfluidics has been touted as being a useful tool for developing new methods to solve complex analytical challenges, and, as such, seems a natural fit for application to proteome profiling. In this review, we summarize the recent progress in the field of microfluidics in four key areas related to this application: chemical processing, sample preconcentration and cleanup, chemical separations, and interfaces with mass spectrometry. We identify the bright spots and challenges for the marriage of microfluidics and proteomics, and speculate on the outlook for progress.

Animals↗

Microreactors as tools for synthetic chemists-the chemists' round-bottomed flask of the 21st century?

Will microreactors replace the round-bottomed flask to perform chemical reactions in the near future? Recent developments in the construction of microstructured reaction devices and their wide-ranging applications in many different areas of chemistry suggest that they can have a significant impact on the way chemists conduct their experiments. Miniaturizing reactions offers many advantages for the synthetic organic chemist: high-throughput scanning of reaction conditions, precise control of reaction variables, the use of small quantities of reagents, increased safety parameters, and ready scale-up of synthetic procedures. A wide range of single- and multiphase reactions have now been performed in microfluidic-based devices. Certainly, microreactors cannot be applied to all chemistries yet and microfluidic systems also have disadvantages. Limited reaction-time range, high sensitivity to precipitating products, and new physical, chemical, and analytical challenges have to be overcome. This concept article presents an overview of microfluidic devices available for chemical synthesis and evaluates the potential of microreactor technology in organic synthesis.

Journal Article↗

Microdevices for manipulation and accumulation of micro- and nanoparticles by dielectrophoresis.

Microfluidic devices with three-dimensional (3-D) arrays of microelectrodes embedded in microchannels have been developed to study dielectrophoretic forces acting on synthetic micro- and nanoparticles. In particular, so-called deflector structures were used to separate particles according to their size and to enable accumulation of a fraction of interest into a small sample volume for further analysis. Particle velocity within the microchannels was measured by video microscopy and the hydrodynamic friction forces exerted on deflected particles were determined according to Stokes law. These results lead to an absolute measure of the dielectrophoretic forces and allowed for a quantitative test of the underlying theory. In summary, the influence of channel height, particle size, buffer composition, electric field, strength and frequency on the dielectrophoretic force and the effectiveness of dielectrophoretic deflection structures were determined. For this purpose, microfluidic devices have been developed comprising pairs of electrodes extending into fluid channels on both top and bottom side of the microfluidic channels. Electrodes were aligned under angles varying from 0 to 75 degrees with respect to the direction of flow. Devices with channel height varying between 5 and 50 microm were manufactured. Fabrication involved a dedicated bonding technology using a mask aligner and UV-curing adhesive. Particles with radius ranging from 250 nm to 12 microm were injected into the channels using aqueous buffer solutions.

Electrophoresis↗

Covalent Modification of Emulsified beta-Casein Resulting from Lipid Peroxidation.

Competitive displacement of adsorbed protein from emulsion droplets by the surfactant Tween 20 has been used to determine the influence of the oil phase and aging on the behavior of beta-casein, the displaced protein being analyzed by reverse-phase high performance liquid chromatography HPLC. Unlike soluble beta-casein or the protein displaced from tetradecane droplets where aging had no effect on the appearance of the HPLC profile, the protein displaced from a soya oil emulsion interface was observed to change. As the soya oil emulsion aged, the retention time of the protein decreased. Mass spectrometry of the modified protein showed that the molecular weight increased, indicating that some form of covalent modification was occurring. Gas chromatography-mass spectrometry of steam distillates of the samples showed the presence of a variety of aldehydes in microfluidized soya oil samples that were not present in either the original oil or the tetradecane emulsions. Aldehydes, particularly alpha,beta-unsaturated aldehydes (enals), which are the major components formed in these soya oil emulsions, are known to react with nucleophilic amino acid side chains such as lysine. This is the probable cause of the observed modification of the emulsified protein. These aldehydes, whose concentration increased with storage time, are formed by peroxidation of the unsaturated fatty acyl chains present in the soya oil as a result of the microfluidization process used in the preparation of the emulsions. The tryptic peptide pattern also changed with age due to modification of the primary structure of the protein. Potential consequences of these chemical changes arising as a result of microfluidization are discussed. Copyright 1999 Academic Press.

Journal Article↗