PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Telemetry”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75Linked to original sources

Clinical benefits of telemetered electrograms in assessment of DDD function.

The advent of telemetry of the endocardial electrogram is a new capability. It must be convenient to use if it is to gain acceptance. Our experience is still growing but already it is confirming information that was either deduced or previously only available by active invasive procedures. The potential value of the technology has only been touched upon in this presentation. We are convinced that it will grow and that its value will be further established as more physicians have an opportunity to use it and gain additional experience.

Ambulatory Care↗

The effect of exercise on the atrial electrogram voltage in young patients.

Atrial electrogram sensing is an important function in active individuals with permanently implanted bipolar dual chamber pacing systems. We undertook to determine the effect of vigorous exercise on the atrial electrogram size in 11 children and young adults (average age 12 years). Using a telemetry signal through a handheld programming wand, nine tracings were completely and clearly recorded for analysis. Six patients had tined/passive fixation atrial leads and three patients had screw-in/active fixation lead systems. All leads were bipolar. The atrial electrogram size for each patient was measured at rest and at each minute of exercise. The atrial electrogram size decreased with exercise from a mean of 5.08 mV to 3.44 mV (range 0.9-4.25 mV) (P = 0.002). The 1.64 mV mean decrease represented a 33.8% reduction (range 19%-56%) (P less than 0.001). There was no difference in the change in atrial electrogram size between the two lead types. Treadmill exercise testing with telemetric data of atrial electrograms showed a decrease in atrial electrogram size produced by exercise and may be helpful in determining appropriate atrial sensitivity settings in selected individuals. Because of the documented decrease in atrial electrogram size produced by exercise, we recommend obtaining maximal atrial electrograms at the time of implant and use of pacing systems that allow maximal flexibility in atrial sensing especially in athletically active individuals.

Adolescent↗

The performance of the probability density function in differentiating supraventricular from ventricular rhythms.

The ability of the probability density function (PDF) of an automatic implantable cardioverter defibrillator (AICD) to reject supraventricular arrhythmias being recognized as ventricular was evaluated in 12 patients who were treated with an AICD (Ventak P 1600). The PDF criterion was monitored via telemetry with the sinus rate during exercise test. PDF was satisfied in seven patients at a rate of 75-144/min (mean 109/min), and not in the remaining five patients (mean rate 141/min). PDF was fulfilled in five of ten patients at a lower heart rate than predicted by the duty cycle index, derived from the ventricular patch lead electrogram at the implantation. Thus PDF is often fulfilled already at a moderately elevated sinus rate. If used to prevent inadvertent AICD discharges during rapid supraventricular rhythms, its performance should be tested in the individual patient.

Electric Countershock↗

Direct and telemetered lead impedance.

OBJECTIVES: We undertook this study to determine whether telemetered lead impedance measurements (LIM) can be correlated with direct LIM and to determine the stability of LIM over time when measured directly and via telemetry. METHODS: Direct LIM and telemetered LIM were measured in 91 patients; 101 leads during initial implantation and 40 leads during pulse generator replacement. Differences in direct LIM measured during initial implant and pulse generator replacement (direct-direct) were compared in 41 patients (28 atrial leads and 37 ventricular leads). The stability of telemetered LIM obtained immediately postoperatively, at 1 month and 1 year, postimplantation was assessed in 50 patients (23 atrial and 49 ventricular leads). RESULTS: In atrial leads acute direct LIM was 633.9 +/- 18.4 omega versus 575.8 +/- 18.5 omega for telemetered LIM (r = 0.58), and chronic direct LIM was 670.9 +/- 49.3 omega versus 607.0 +/- 36.3 omega for telemetered LIM (r = 0.87). In ventricular leads acute direct LIM was 747.3 +/- 16.9 omega and 684.7 +/- 16.4 omega for telemetered LIM (r = 0.69), and chronic direct LIM was 674.8 +/- 29.9 omega and 625.2 +/- 28.5 omega for telemetered LIM (r = 0.68). The mean direct-direct LIM rose 124 omega (P < 0.001) in atrial leads and 10 omega (P = NS) in ventricular leads. Telemetered LIM for atrial leads was 581.0 +/- 27.6 omega immediately postimplantation compared to 625.7 +/- 34.8 omega at 1 month and 754.1 +/- 43.0 omega at 1 year. Telemetered LIM for ventricular leads was 661.3 +/- 17.5 omega at implant, 684.6 +/- 20.7 omega at 1 month and 724.7 +/- 22.7 omega at 1 year. CONCLUSIONS: There is a good but limited correlation between direct and telemetered LIM. Mean direct LIM obtained at initial implantation is similar to that measured at pulse generator replacement. The telemetered LIM is stable over the first month postimplantation but tends to rise during the first year of follow-up and substantial changes in impedance are not uncommon in individuals with normal function. There is a tendency for LIM to rise with lead maturation. If telemetered LIM is to be followed over time, a baseline telemetered value should be obtained immediately postoperatively.

Electric Impedance↗

P wave oversensing in a unipolar VVI pacemaker.

A 45-year-old male had a VVI pacemaker implanted 20 years ago because of complete heart block. Because of perforation of the lead the pulse generator was removed after 4 weeks and a second lead was implanted from the contralateral side. Recently, the patient presented with symptoms of lightheadedness and syncope associated with prolonged pauses in the electrocardiogram. From the ECG, the ECG interpretation channel, and intracardiac electrogram telemetry, it was concluded that the VVI pacemaker was inhibited by P waves. The most likely explanation for this phenomenon was an insulation defect in the functioning lead caused by friction with the abandoned lead at the level of the high right atrium.

Electrocardiography↗

Effects of nuclear magnetic resonance imaging on cardiac pacemakers.

Patients with cardiac pacemakers are currently restricted from nuclear magnetic resonance imaging (MRI). The aim of the study was to analyze the influence of MRI on new generation pacemakers. Tests were performed using a phantom model with seven dual chamber and two single chamber systems in a 0.5 Tesla MRI scanner. Monitoring by telemetry and oscillography were used during the standard clinical scan sequences as well as a pacemaker inquiry after each sequence. Spin echo, gradient echo, and fast field echo sequences were performed with the following stimulation modes: VVI, VVIR, VOO, DDD, DDDR, and DOO. On entering the static magnetic field, the reed switch was activated followed by asynchronous stimulation. The subsequent scan showed no influence on the stimulation function nor on the pacemaker program. Event counter function remained intact. Pacemakers with automatic mode switching to demand pacing or programmed inactivation of the reed switch were triggered in the dual chamber mode and were inhibited in the one chamber mode during the scan. Alterations of pacemaker program or rapid pacing were not observed. MRI scan could induce voltage as high as intracardiac signals, but the stimulation threshold of the heart was not reached. Thus, pacemakers should be programmed in the asynchronous mode during scan to avoid inhibition and trigger mechanism.

Acrylic Resins↗

Optimized standby rate reduces the ventricular rate variability in pacemaker patients with atrial fibrillation.

Patients with chronic atrial fibrillation (AF) and symptomatic bradycardia often receive ventricular-based pacemakers. However, many of these patients continue to have symptoms of palpitations, which may be due to ventricular rate variability. It has previously been shown that continuous ventricular pacing during AF has a stabilizing effect on the ventricular rate. Hence, a study was initiated to determine whether a patient-specific optimal ventricular standby rate that reduces the ventricular rate variability, without over-pacing, could be predicted. A ventricular rate stabilization (VRS) pacing algorithm that increases the pacing rate until instability is reduced below a threshold was developed. The VRS algorithm was utilized to determine a patient-specific standby rate in 15 patients with chronic AF, intact AV nodal conduction, and implanted pacemakers. The computer algorithm controlled a pacemaker programmer to automatically change the pacemaker's ventricular pacing rate via telemetry. Patients were studied for 15 minutes with VRS and for 15 minutes with 50 ppm fixed rate pacing (control). The results were as follows: (1) VRS versus control = P < 0.05; (2) mean ventricular pacing rate (ppm): 77 +/- 13 versus 50 +/- 0; (3) mean ventricular rate (beats/min): 82 +/- 13 versus 79 +/- 12; (4) ventricular rate coefficient of variation (%): 11 +/- 1 versus 22 +/- 5; (5) percent pacing: 75 +/- 8 versus 6 +/- 8; (6) percent of RR intervals less than minimum pacing interval eliminated: 58 +/- 12; (8) regression analysis: mean VRS pacing rate (beats/min) = 0.96 x mean control ventricular rate + 2.3, r2 = 0.85. We concluded that: (1) a moderate increase in the ventricular pacing rate was required to substantially stabilize the ventricular rate; (2) the resulting mean ventricular rate increased marginally; (3) a majority of RR cycles less than each patient's minimum pacing interval were eliminated; and (4) there was a linear relationship between the mean ventricular rate during control and the optimal ventricular pacing rate. Thus, a ventricular pacing rate close to the mean ventricular rate during control consistently reduced the ventricular variability. Although pacing at an increased ventricular standby rate reduces variability at rest, the optimal solution would likely be an adaptive rate algorithm that changes the ventricular standby rate as the mean intrinsic rate varies.

Aged↗

Exercise induced sympathetic influences do not change interatrial conduction times in VDD and DDD pacing.

Using telemetry, right atrial electrogram (RA), and marker channel of atrial sense events (MA) in combination with the left atrial electrogram (LA), recorded by a filtered bipolar esophageal lead, interatrial conduction during submaximal exercise and at rest was examined in 46 DDD pacemaker patients. The RA-LA and MA-LA conduction times measured in the presence of atrial sensing (VDD) as well as the conduction time SA-LA from atrial stimulus (SA) to LA, determined during atrial pacing (DDD) were found to be individual constants independent of exercise induced sympathetic influences. Thus, having determined an optimal mechanical interval (LA-LV)mech/opt from left atrium to ventricle by other methods, the optimal AV delay for DDD as well as for VDD operation can be calculated by the sum of the appropriate interatrial conduction time (SA-LA, respectively MA-LA) and the (LA-LV)mech/opt interval. Due to the constant SA-LA and MA-LA, the difference between these two values (AV delay correction interval) is a constant as well, which remains unchanged during exercise. Therefore, in selecting the rate responsive AV delay, only hemodynamic and not electrophysiological measurements need to be considered.

Aged↗

Initial experience with 1.5-mm2 high impedance, steroid-eluting pacing electrodes.

UNLABELLED: In this human study, 21 atrial and 62 ventricular 1.5-mm2 unipolar steroid-eluting pacing electrodes were implanted in 64 patients. Pacing thresholds, lead impedance, and sensing measurements were measured via pacemaker telemetry within 24 hours postimplant, and at 1, 2, 3, 4, 6, 12, 24, and 52 weeks. Acute pacing impedances measured via a pacing systems analyzer were 1,039 +/- 292 (atrial) and 1,268 +/- 313 ohms (ventricular). A 10%-15% decline in the mean telemetered atrial and ventricular pacing impedances was observed at 1 week, but thereafter remained stable. Acute pacing thresholds at 0.5 ms were 0.5 +/- 0.3 V (atrial) and 0.4 +/- 0.1 V (ventricular). Filtered P and R wave amplitudes were 3.7 +/- 2.3 mV and 14.9 +/- 5.9 mV, respectively. In 21 patients, no complications related to the atrial electrode were observed. Of 62 patients with ventricular electrodes, 4 patients (6%) experienced complications and required surgical intervention. On these, causative factors included micro-dislodgment (1 patient), and perforation (1 patient). Sudden unexplained exit block occurred late (> 6 weeks) in two patients. In the remainder of patients, pacing thresholds and sensed electrogram amplitudes remained stable throughout the 52-week follow-up period. CONCLUSIONS: The present study validates that smaller surface (i.e., 1.5 mm2) steroid-eluting electrode designs offer excellent pacing and sensing performance with significantly higher pacing impedances. Although questions remain as to the cause of late exit block in two patients in this series, this relatively small surface electrode design offers promise toward achieving greater pacing efficiency and a theoretical 13%-16% (minimum) enhancement in permanent pacemaker longevity.

Administration, Topical↗

VDD(R) pacing: short- and long-term stability of atrial sensing with a single lead system.

BACKGROUND: Recent studies have shown that the atrial signal can reliably be sensed for VDD(R) pacing via atrial floating electrodes incorporated in a single-pass lead. However, there remains concern about the long-term stability of atrial sensing and proper VDD function under real-life conditions. This study investigated the long-term reliability of atrial sensing and atrioventricular synchronous pacing using a new single lead VDD(R) pacing system. METHODS AND RESULTS: In 20 consecutive patients (ages 71 +/- 14 years) with normal sinus node function and high-degree heart block, a single lead VDD(R) pacemaker (Unity, Intermedics) was implanted. Atrial sensing was studied at implantation, at discharge, and at 1, 3, 6, 12, and 18 months of follow-up. At implant, the measured P wave amplitude was 2.3 +/- 1.2 mV. By telemetry, the atrial sensing threshold was 0.79 +/- 0.41 mV at discharge, 0.75 +/- 0.43 mV at 1 month, 0.73 +/- 0.43 mV at 3 months, 0.76 +/- 0.41 mV at 6 months, 0.79 +/- 0.41 mV at 12 months, and 0.77 +/- 0.35 mV at 18 months of follow-up (P = NS). Appropriate VDD pacing was assessed by the percentage of correct atrial synchronization (PAS = atrial triggered ventricular paced complexes divided by total number of ventricular paced complexes) during repeated Holters. PAS was 99.99% +/- 0.01% at 1 month, 99.99% +/- 0.02% at 3 months, and 99.98% +/- 0.05% at 12 months of follow-up (P = NS). No atrial oversensing with inappropriate ventricular pacing was observed, neither during isometric arm exercise testing nor spontaneously during Holter monitoring. CONCLUSION: The long-term stability of atrial sensing with almost 100% correct atrial synchronous tracking and the lack of inappropriate pacing due to atrial oversensing make the new Unity VDD(R) system a highly reliable single lead pacing system. In view of the lower costs and the ease of single lead implantation, this system may offer an interesting alternative to DDD pacemakers in patients with normal sinus node function.

Aged↗

A fractally coated, 1.3 mm2 high impedance pacing electrode.

Minimizing the geometric surface area of pacing electrodes increases impedance and reduces the current drain during stimulation, provided that voltage (pulse-width) thresholds remain unchanged. This may be feasible by coating the electrode surface to increase the capacity of the electrode tissue interface and to diminish polarization. Ten unipolar, tined leads with a surface area of 1.3 mm2 and a "fractal" coating of iridium (Biotronik SD-V137) were implanted in the ventricle, and electrogram amplitude (unfiltered), slew-rate, pacing threshold (0.5 ms), and impedance (2.5 V; 0.5 ms) were measured by the 5311 PSA (Medtronic). On days 0. 2. 5. 10, 28, 90, 180, 360 postimplant, sensing threshold (up to 7.0 mV, measuring range 1-14 mV on day 360 only) and the strength duration curve (0.5-4.0 V; 0.03-1.5 ms; steps: 0.5 V; 0.01 ms, respectively) were determined, the minimum charge delivered per pulse (charge threshold), and the impedance were taken from pacemaker telemetry (Intermedics 294-03). Data were compared with those of an earlier series of 20 unipolar, tined TIR-leads (Biotronik) with a surface area of 10 mm2 and a @actal" coating of titanium nitride. With the model SD-V137 versus TIR, intraoperative electrogram amplitudes were 15.1 +/- 6.1 versus 14.4 +/- 3.9 mV (NS), slew rates 3.45 +/- 1.57 versus 1.94 +/- 1.06 V/s (P < 0.05), pacing thresholds 0.16 +/- 0.05 versus 0.52 +/- 0.15 V (P < 0.01) and impedance measurements 1,136 +/- 175 versus 441 +/- 73 omega (P < 0.0001), respectively. During follow-up, sensing thresholds were the same with both leads. Differences in pulse width thresholds lost its significance on day 28 but resumed on day 360 (SD-V137; 0.08 +/- 0.04 ms; TIR: 0.16 +/- 0.06 ms at 2.5 V; P < 0.01). With an electrode surface of 1.3 mm2, charge per pulse and impedance consistently differed from control, being 0.15 +/- versus 0.66 +/- 0.20 microC (P < 0.001) and 1,344 +/- 376 versus 538 +/- 79 omega respectively, one year after implantation (P < 0.0001). In summary, "fractally" coated small surface electrodes do not compromise sensing; by more than doubling impedance against controls they offer pacing thresholds (mainly in terms of charge) that are significantly lower than with the reference electrode.

Aged↗

Noninvasive rejection monitoring of cardiac transplants using high resolution intramyocardial electrograms: initial US multicenter experience.

Endomyocardial biopsy (EMB) remains the mainstay for the diagnosis of acute cellular rejection in cardiac transplant patients. A noninvasive alternative that would supplant or reduce the number of EMBs would be a highly desirable and cost-effective tool. To evaluate one potential alternative, a pacemaker with high resolution telemetry capabilities and two fractally coated epimyocardial leads were implanted in 30 patients at five transplant centers during the heart transplant procedure. Ventricular electrograms were recorded during intrinsic and paced activity and digitized to a laptop-based data acquisition device. Electrograms were recorded at frequent intervals and systematically on days when EMBs were performed. The electrogram data were then transferred via the Internet to a central data processing site. Clinical patient management was blinded to the electrogram results and varied considerably among the five centers. Using EMB together with clinical assessment of the transplant revealed 18 cases of clinically significant rejection beyond postoperative day 27 that required antirejection therapy. The normalized parameter values extracted from the electrogram recordings during pacing (the ventricular evoked response) that were associated with significant rejection were statistically lower (86% +/- 16% versus 96% +/- 22%, P < 0.005). The application of a single-threshold diagnosis model to the parameter values allowed detection of significant rejection with a negative predictive value of 98%. This analysis also showed that as many as 55% of the routine surveillance EMBs could have been eliminated had the pacemaker monitoring technique been used as a screening tool prior to EMB. A prospective study should further define the role of this technique in the detection and management of cardiac transplant patients.

Electrocardiography↗

Reliability of single-lead VDD atrial sensing and pacing during exercise.

If atrial sensing ability of a single-lead VDD pacemaker is well accepted at rest, the detection quality by atrial floating electrodes remains less recognized during exercise. The aim of this study was to verify, during treadmill test and a continous telemetry, the atrial tracking performance using four different leads technologies. From November 1994 to July 1997, 21 patients (71.3 +/- 6.3 years old, 7 female, cardiopathy: 57%) were paced for isolated high degree (permanent: 13, paroxystic: 8) AV block. The implanted devices were the Vitatron Saphir/Brillant lead (13 patients), Intermedics Unity/425/04-13 lead (5 patients), Pacesetter Addvent (2 patients), and Biotronik Eikos (1 patient). The acute atrial signal amplitude was 1.66 +/- 0.75 mV. The treadmill test used the chronotropic assessment exercise protocol after pacemaker reprogramming to detect atrial undersensing (AV delay < or = 120 ms, no hysteresis, no flywheel, upper rate increase). The mean delay was 31.1 weeks (range 1-100). The testing duration was 6.1 +/- 2.3 minutes, the number of steps was 3.3 +/- 1.3 per patient, and the peak exercise rate was 135 +/- 19 beats/min. At rest, complete atrial tracking was complete in 90% of the patients, and during testing in only 23.8% of the patients, while AV synchronization > 95% was present in 57.1%, > 90% in 71.4%, and > 85% in 90.4% of patients (Vitatron 13/13, Intermedics 3/5, Biotronik 1/1, and Pacesetter 1/2). During the recovery period synchronization was always > 95%. The mean P wave amplitude at rest was 1.1 +/- 0.5 mV; during the first step, 1.04 +/- 0.61 mV; second step, 0.94 +/- 0.53 mV; third step, 0.82 +/- 0.58 mV; fourth step, 0.67 +/- 0.39 mV; and during recovery, 1.13 +/- 0.67 mV. The mean P wave decrease signal at peak of exercise is 0.21 mV (from -1.31 to +0.5). In fact, P wave variations have several patterns: a decrease was measured in 7 patients, an increase in 2 patients, and no significant change in 7 patients. Single-lead VDD P wave identification during exercise was almost accurate. However, often there was progressive lowering of atrial sensing with transient loss of AV synchrony.

Aged↗

Atrial sensing and AV synchrony in single lead VDD pacemakers: a prospective comparison to DDD devices with bipolar atrial leads.

INTRODUCTION: Single lead VDD pacing has offered an alternative to DDD systems in patients with isolated AV block. Up to now, however, the relative performance of these pacemaker systems was not systematically compared. METHODS AND RESULTS: Three hundred sixty patients who received either a VDD pacemaker (n = 180) or a DDD device (n = 180) with a bipolar atrial lead were investigated prospectively for a mean period of 30 +/- 13 months. Pacemaker function was analyzed by telemetry, Holter monitoring, and exercise ECG. Time of implantation and fluoroscopy was significantly lower with VDD devices (44.3 +/- 5.1 min vs 74.4 +/- 13.5 min and 4.6 +/- 2.5 min vs 10.3 +/- 5.6 min in DDD pacemakers, respectively). Intermittent atrial undersensing occurred in 23.3% of patients with a VDD pacemaker and in 9.4% with DDD devices (NS). The incidence of atrial tachyarrhythmias did not differ between the VDD (6.7%) and the DDD group (6.1%). Sinus node dysfunction developed in 1.9% of patients, but the vast majority (85.7%) of patients were asymptomatic. There was a tendency for a higher rate of operative revisions in the DDD group (6.1% vs 3.3% in VDD pacemakers, P = 0.15). Cumulative maintenance of AV-synchronized pacing mode was 94.9% in patients with VDD pacemakers and 92.1% with DDD devices (NS). CONCLUSION: With the benefit of a simpler implant procedure, long-term outcome of single lead VDD pacing is equivalent to DDD pacing in patients with AV block and preoperative normal sinus node function.

Aged↗

Symptomatic and asymptomatic atrial fibrillation in patients undergoing radiofrequency catheter ablation.

INTRODUCTION: The goals of this study were to (i) evaluate the feasibility and results of monitoring patients prior to and following catheter ablation of AF with the mobile cardiac outpatient telemetry (MCOT) system and to (ii) correlate symptoms and the presence or absence of atrial fibrillation (AF). METHODS AND RESULTS: A total of 19 consecutive patients (12 men [63%]; age 60 +/- 6 years) with highly symptomatic drug refractory AF underwent catheter ablation. Each was provided with a MCOT monitor (CardioNet, USA) and asked to wear it 5 days immediately before the ablation, and 5 days per month starting with the ablation for 6 consecutive months. When patients experienced any symptoms, they were asked to activate the system and to record associated symptoms. A total of 494 days (11,856 hours) were monitored. Out of the total 390 events triggered by patient's symptoms, 40% were confirmed as AF events (156) and 60% were confirmed as non-AF events (234). Only shortness of breath and chest discomfort were highly associated with AF (P < 0.05). At the end of 6 months of follow-up, out of 10 patients that completed the study, 7 (70%) patients were free of symptomatic AF recurrences whereas only 5 (50%) patients achieved success when asymptomatic AF recurrences were included in the outcome. CONCLUSIONS: The results of this study demonstrate the potential utility of wireless monitoring systems in the follow-up of AF ablation patients, while also identifying poor patient compliance with an intensive monitoring protocol as an important limitation.

Atrial Fibrillation↗

Ambulatory esophageal pH monitoring using a wireless system.

OBJECTIVE: Limitations of catheter-based esophageal pH monitoring are discomfort, inconvenience, and interference with normal activity. An alternative to conventional pH monitoring is the wireless Medtronic Bravo pH System. The aim of this study was to evaluate the safety, performance, and tolerability of this system. METHODS: A total of 44 healthy subjects and 41 patients with gastroesophageal reflux disease (GERD) were studied for a 2-day period. The pH telemetry capsule was positioned transorally 6 cm above the squamocolumnar junction using endoscopic measurement. The signal transmitted from the capsule was received and recorded by a small, pager-sized receiver, and pH data were subsequently uploaded to a computer for analysis. RESULTS: Successful 24-h pH studies were completed in 82 subjects (96%). During the 24-h study period the median percentage of the time that pH was <4 was 2.3% (95th percentile, 5.9%) in controls and 6.5% (range, 0.8-27.6) in GERD patients. In 76 subjects (89%), 36-48 h recordings were obtained. For the extended period the median percentage of the time that pH was <40 was 2.0% (95% percentile, 5.3%) in controls and 6.6% (range, 1.0-26.7) in GERD patients. Capsules required endoscopic removal in three subjects (4%). Optimal sensitivity in distinguishing controls from reflux patients was achieved when analyzed from the perspective of the worst of the 2 days. CONCLUSIONS: The wireless Bravo pH System successfully recorded esophageal acid exposure in 96% of the patients during a 24-h period and in 89% of subjects for >36 h. The 95th percentile for the 2-day recordings in control subjects was 5.3%, slightly higher than observed with conventional systems.

Adult↗

Forty hours under pressure: a rapid-response improvement team achieves synergy.

A rapid-response team process was used to achieve unique team synergy and project success. The team's mission was to reduce the waiting time in the emergency care unit for inpatient telemetry beds. Data needed for root cause analysis were collected before the first team meeting, and "just-in-time" team training was provided at the team's first meeting. With leadership from the chief executive officer, a vice president, and a core group of physicians, the team was energized to complete the mission and present its plan to the entire executive team at the end of just 1 week.

Bed Occupancy↗

The development of a radio-stethoscope for use in the horse at rest and during exercise.

The development of a radio-stethoscope for horses is described. The equipment consisted of a sound transducer applied to the skin adjacent to the trachea and a radio transmitter attached to the saddle. The signals emitted were detected by telemetry and recorded on a magnetic tape-recorder. The recorder incorporated a monitor earphone so that sounds could be reproduced at the time of recording. The frequency response obtainable ranged from a few Hz to 4 KHz. This technique provided an objective means of studying the respiratory sounds generated during exercise although absolute values could not be measured.

Animals↗