PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76Linked to original sources

Tentative application of the tangent simple system method to the study of the viscoelastic behaviour of blood.

The method of the tangent simple systems is applied to the study of the viscoelastic behaviour of human blood in unstationary flow for rectangular steps and triangular ramps of shear rate. The tangent systems we utilize, Maxwell liquids, enable us to determine, at every point of the rheograms, apparent instantaneous values of retardation or relaxation time, viscosity coefficient and elasticity modulus of the studied blood samples, and to plot the curves of variation of these parameters as a function of flow duration. A qualitative interpretation of the results is proposed from data on the aggregation-disaggregation kinetics of red blood cells. Examples are given for samples of normal and pathological bloods.

Biomechanical Phenomena↗

Quantitative assessment of platelet function and clot structure in patients with severe coronary artery disease.

The prothrombotic state of patients with coronary artery disease (CAD) can be attributed partially to platelet activity. Management of such patients is hindered by a lack of techniques to assess hemostatic function. This study used a sensitive technique to monitor platelet function by measuring platelet force development during clot retraction. This technique allowed simultaneous measurement of clot elastic modulus on the same sample. Fibrin mass-length ratio (mu), fibrinopeptide A, D-Dimer, von Willebrand's factor, thromboxane A2, platelet aggregation studies, and bleeding times also were performed. Fourteen patients with CAD were compared with 10 healthy volunteers. Despite more than 95% suppression of thromboxane B2 and prolongation bleeding times in patients taking aspirin, force development remained significantly elevated over healthy control patients (8,279 +/- 476 dynes versus 4,857 +/- 380 dynes, p < 0.0006). Patients not taking aspirin had normal bleeding times and force development of 19,110 +/- 3,700 dynes. Clot elastic moduli were enhanced in patients with CAD whether taking or not taking aspirin. Adenosine diphosphate and ristocetin-induced platelet aggregation were insensitive to the effect of aspirin in patients with CAD. Fibrinopeptide A, von Willebrand's factor, and D-Dimer levels were significantly elevated, and fibrin mass-length ratios were significantly larger in patients with CAD. Therefore, despite aspirin therapy, patients with severe CAD have evidence of persistent platelet activation and rigid clot structure. Monitoring of platelet force development may prove useful in delineating enhanced platelet function.

Adult↗

Significance of right ventricular filling for left ventricular enddiastolic pressure-volume relationship under acute hypoxia in the dog.

In 14 closed-chest dogs, the significance of right ventricular filling for left ventricular enddiastolic pressure-volume relationship was investigated under acute hypoxia by means of single plane cineventriculography and simultaneous intraventricular pressure recording. Both after 5 min asphyxia (respirator switched off) (n = 5) and after 3 min hypoxia (ventilation with pure N2) (n = 9), there was a significant leftward shift (p less than 0.005) of the left ventricular enddiastolic pressure-volume curve as compared to the control curves under normoxia. To simulate the elevated filling of the right ventricle under acute hypoxia, rapid intraventricular infusion was applied under normoxic conditions to raise right ventricular enddiastolic pressure to the same values as that measured under hypoxia. The extent of the ensuing leftward shift of the left ventricular enddiastolic pressure-volume curve was on average 60% of the shift under hypoxia in both sets of experiments. Neither the slope of the relationship between volume stiffness and enddiastolic pressure, nor the relationship between tangent elastic modulus and left ventricular wall stress, was affected by hypoxia or asphyxia. Thus, the shift of the left ventricular enddiastolic pressure-volume curve in the early stage of hypoxia is predominantly due to the influence of increased right ventricular filling. Since the increased volume of the atria under acute hypoxia limits left ventricular distensibility additionally, the changes in left ventricular enddiastolic pressure-volume relationships observed in the early stage of hypoxia are mainly, or even entirely, the result of interaction of the various heart compartments, and not a reflection of alterations in myocardial tissue elasticity.

Animals↗

Semisolid SLN dispersions for topical application: influence of formulation and production parameters on viscoelastic properties.

Aqueous solid lipid nanoparticle (SLN) dispersions with a high lipid content up to 35% and viscous to semisolid consistency were produced by a high pressure homogenization process. Despite their high lipid content and viscosity these dispersions preserved their colloidal size range. The SLN dispersions were compared to nanoemulsions and microparticle dispersions with regard to particle size, viscoelastic properties and formation of a semisolid gel structure. Viscoelastic measurements including oscillation stress sweep tests and oscillation frequency sweep tests demonstrated that the existence of a solid particle matrix with a particle size in the nanometer range is a prerequisite to form a semisolid dispersion having the appropriate consistency for topical application. Striking differences were observed between solid lipid micro- and nanodispersions of the same composition. Particle size reduction resulted in an 80-fold increase of the elastic modulus. Particle size distribution, the physical state of the dispersed lipid phase and the emulsifier concentration have been identified as further key factors for the viscoelastic properties and gel structure of the lipid nanodispersions. By conducting oscillation measurements it was possible to relate the stability of lipid dispersions to specific rheological parameters therefore providing a sensitive tool in stability assessment. Changing the production process from a 40 ml batch to a 2 l batch turned out to have an influence on the colloidal structures of semisolid SLN dispersions. Consistency increased but particle size and ratio of elastic to viscous properties stayed in the same range.

Administration, Topical↗

Desferrioxamine release from gelatin-based systems.

The conventional treatment with regular red-blood-cell transfusions and simultaneous chelation of excess iron with DFO (desferrioxamine) improves quality of life of thalassaemic patients while increasing their rate of survival considerably. Although DFO is the main iron- chelating drug currently utilized, it has various drawbacks, including high cost, poor oral effectiveness, toxicity and short plasma half-life. It has to be administered by slow, subcutaneous infusion during blood transfusion for 8-12 h at night, 5-7 nights a week, and this leads to a very poor patient compliance. In order to avoid frequent and uncomfortable infusions of DFO, application of controlled-release systems might be alternative routes in the supportive treatment of thalassaemia. In the present study, GMs (gelatin microspheres) and GFs (gelatin films) were prepared by coacervation and casting methods respectively to develop controlled DFO-release systems. Cross-linking by glutaraldehyde and carbodi-imide were performed to increase the stability of gelatin matrices. Microspheres and films prepared without the addition of cross-linker degraded completely in 4 h. On the other hand, addition of cross-linker extended this time from hours to weeks depending on the added amount. Therefore the amount of DFO released from microspheres in 7 days was found to be in the range 12-82%, whereas the amount permeated through the films in 5.0 h was found to be in the range 34-67%. GFs were elastic and demonstrated good mechanical properties. Films achieved 0.14-0.69 MPa tensile strength, with 0.12-1.29 MPa elastic modulus and 26.49-109.38% strain values at break point. These studies showed that gelatin-based controlled-release systems could be improved and could be good candidates for the production of long-term DFO-carrying systems.

Biocompatible Materials↗

Viscoelastic properties of the human temporomandibular joint disc in patients with internal derangement.

PURPOSE: This study investigated the viscoelastic properties of human temporomandibular joint (TMJ) discs in patients with severe internal derangement (ID). PATIENTS AND METHODS: TMJ discs obtained from 5 patients with severe TMJ internal derangement were analyzed. Normal discs derived from 2 fresh cadavers and 4 patients without ID served as the controls. The viscoelastic responses of the discs to tensile forces were evaluated by means of stress-strain analyses. RESULTS: The discs in both groups exhibited a nonlinear stress-strain relationship that was represented by a power function of the strain. However, after stress relaxation, the ID discs were likely to exhibit a linear stress-strain relationship. The instantaneous elastic moduli were almost the same in both discs, but the relaxed elastic modulus of the ID discs was significantly greater than that of the controls in lower strain range of less than 2%. CONCLUSIONS: ID discs are more rigid than normal discs. These findings suggest that the changes in viscoelastic property of the discs in patients with ID are somewhat different from those that occur with aging.

Adult↗

[A study on the improvement of denture base resin. Epoxy dimethacrylate-polybutadiene dimethacrylate-MMA monomers as the liquid of denture base resin].

The dimethacrylates, EpDMA and BdDMA, which have a bisphenol type epoxy chain and butadiene chain in their main chains, respectively, were synthesized. The properties of the terpolymer composed of EpDMA, BdDMA and MMA monomers were examined. The monomer mixture of EpDMA, BdDMA and MMA was used as the liquid of denture base resin, and the properties of the cured resin were examined. The polymerization shrinkage of the terpolymer of EpDMA-BdDMA-MMA decreased with the increase in the EpDMA concentration in the cured resin, and the transverse strength and the elastic modulus were greatest at the BdDMA concentration of 0.3-1 vol%. The denture base resin produced using a monomer mixture as the liquid, the transverse strength and the impact strength showed the highest values of about 110 MPa and 14 KJ/m2, respectively, at the liquid composition of 10 vol% EpDMA, 1 vol% BdDMA and 89 vol% MMA.

Butadienes↗

Mucus viscoelasticity and mucociliary transport rate.

The aim of this research was to define in quantitative terms the relationship between the viscoelastic properties of mucus and the velocity at which it can be transported by a ciliated mucosa. To this effect, tests were performed on frog palates with normal beating cilia which were washed free of endogenous mucus. Experimental sputum samples encompassing a wide range of viscoelastic properties were applied to the palates, and their transport velocity was measured under a dissecting microscope. The results indicated that the fastest transport, per palate, was achieved by sputa whose Newtonian viscosity and linear elastic modulus fell within the range of 1,000 to 3,000 poises and 10 to 25 dynes/cm2, respectively. The transport velocity decreased when the sputum viscoelasticity was above or below this optimal range. The latter condition is of particular importance since it indicates that marked fluidification may hinder rather than promote mucus clearance.

Animals↗

Echocardiographic evaluation of pulmonary artery distensibility.

The aim of this study was to verify the hypothesis that pulmonary artery (PA) distensibility may modify the pattern of right ventricular ejection. Pulmonary artery distensibility was evaluated with M-mode measurements of right pulmonary artery diameter from suprasternal notch simultaneous with pulmonary pressure measurements. Pulmonary artery pressure was measured in 19 subjects, 29 to 75 years old (mean age, 49 years). Pulmonary artery systolic pressure was 22 to 108 mm Hg (mean, 52 mm Hg). Pulmonary artery pressure strain modulus (Ep) was calculated as follows: PADD x (PASP-PADP)/PADD-PADS (PADS-PA diameter in systole, PADD-PA diameter in diastole, PASP-PA systolic pressure, PADP-PA diastolic pressure) was 6 +/- 8 10(5) dynes/cm2. Right ventricular outflow tract velocity was recorded with pulsed Doppler echocardiography and acceleration times (AT) and ejection times (ET) were measured. Log Ep was correlated with pulmonary artery systolic and mean pressure (r = 0.90 and r = 0.87, p < 0.0001) but not with age (r = 0.30, p = NS). Acceleration time and AT/ET ratio were correlated with log Ep (r = 0.73 and r = 0.76, p < 0.001) and with pulmonary artery mean pressure (r = 0.91 and r = 0.89, p < 0.0001). When pulmonary artery pressure was included in multiple analyses, the relationships between Doppler indices and elastic modulus did not prove to be significant. These findings emphasize the independence of Doppler right ventricular outflow tract velocity indexes used for noninvasive evaluation of pulmonary hypertension from pulmonary artery distensibility in a clinical setting.

Adult↗

Deduction of intrinsic mechanical properties of the erythrocyte membrane from observations of tank-treading in the rheoscope.

Measurements of the dimensions and membrane rotational frequency of individual erythrocytes steadily tank-treading in a Rheoscope are used to deduce the surface shear viscosity (eta m) and the shear elastic modulus (mu m) of the membrane. Previously published algorithms (Trans-Son-Tay et al., Biophys. J. 46: 65, 1984, and 51: 915, 1987) plus an assumed area-conserving membrane velocity field (Secomb and Skalak, Q. J. Mech. Appl. Math. XXXV 2: 233, 1982) are applied to calculate eta m as a function of the second invariant of the surface strain rate and mu m as a function of the second invariant of membrane strain. The results indicate density-related increases in membrane stiffness and viscosity, shear-thinning viscous behavior, and strain-stiffening elastic behavior.

Algorithms↗

Molecular assessment of the elastic properties of collagen-like homotrimer sequences.

Knowledge of the mechanical behavior of collagen molecules is critical for understanding the mechanical properties of collagen fibrils that constitute the main architectural building block of a number of connective tissues. In this study, the elastic properties of four different type I collagen 30-residue long molecular sequences, were studied by performing stretching simulations using the molecular mechanics approach. The energy-molecular length relationship was achieved by means of the geometry optimization procedure for collagen molecule strains up to 10%. The energy was interpolated by a second order function, and the second order of the derivative with respect to the mean length corresponded to the molecule stiffness. According to the hypothesis of linear elastic behavior, except for one sequence, the elastic modulus was around 2.40 GPa. These values are larger than fibril values, and they confirm the hypothesis that tendon mechanical properties are deeply related to tendon hierarchical structure. A possible explanation of the lowest values obtained for one sequence (1.33-1.53 GPa) is provided and discussed.

Biomechanical Phenomena↗

Rhodamine phalloidin F-actin: critical concentration versus tensile strength.

The mechanic and elastic properties of rhodamine phalloidin F-actin were investigated as a function of the ionic strength and in the absence of Mg2+. By increasing ionic strength from 3 to 19 mM, critical concentration decreased from 146 to 36 nM and the yield strength increased from 5.6 pN to 28.6 pN. At the ionic strength of 12-13 mM, the elastic modulus by stretching increased by 330-430 kP. nm-1 up to the break point, where it was 38-44.2 MP. The work required to break the filament, 403-439 kJ.M-1 provides an estimate of the free energy of annealing of rhodamine phalloidin F-actin, the annealing constant being 2.8 x 1074 M-1.

Actins↗

[Visco-elastic properties of various composites for the front teeth].

The rupture load, elasticity modulus and viscosity coefficient of certain composite currently on sale for the reconstruction of front teeth were calculated experimentally. The products examined were: Prismafil (Caulk), Helioprogress (Vivadent), Heliosit (Vivadent), Silux (3M), Concise (3M), Command Ultrafine (Kerr), P30 (3M). The figures obtained relate to 3 different time periods after the preparation of samples.

Composite Resins↗

Validation of a small punch testing technique to characterize the mechanical behaviour of ultra-high-molecular-weight polyethylene.

The small punch or miniaturized disc bend test has been used successfully to characterize the ductility and fracture resistance of metals and ceramics with specimens measuring 0.5 mm in thickness. This study was performed to demonstrate the feasibility of performing small punch tests on implant grade ultra-high-molecular-weight polyethylene (UHMWPE). Large-deformation finite element simulations were developed and validated to explore the hypothesis that the macroscopic constitutive behaviour of UHMWPE may be inferred from a miniature specimen testing technique which can be used to characterize the ductility and work to failure for UHMWPE. The load-displacement curve was insensitive to cyclic preconditioning of the test specimen and only mildly sensitive to the loading rate. Furthermore, the initial slope of the small punch load-displacement curve was used to determine the elastic modulus of the UHMWPE with the help of the inverse finite element method. The ultimate goal of this research is to develop the capability to perform local measurements of material tensile and static fracture properties in as-manufactured, as-sterilized and as-retrieved UHMWPE components.

Biocompatible Materials↗

Connection of smooth muscle cells to elastic lamellae in aorta of spontaneously hypertensive rats.

We have recently demonstrated that in large arteries of spontaneously hypertensive rats (SHR), there is no increase of stiffness despite the increase in wall thickness, a sign of mechanical adaptation of the arterial wall to the higher level of stress. Because the dense plaques of smooth muscle are a major site of anchorage between the muscle cells and extracellular matrix, we determined by electron microscopy the distribution of dense plaques and their connections to elastic lamellae in the abdominal aorta of 1-year-old SHR and control Wistar rats. In vivo echo-tracking measurement of aortic distensibility and elastic modulus indicates a reduction of arterial stiffness in SHR compared with Wistar rats when they are studied over a common range of blood pressure. The media thickness to body weight ratio was higher in SHR than in Wistar rats. In the media, the percentage of sectional area occupied by extracellular matrix was not different between Wistar rats and SHR. The average number of dense plaques per muscle cell was not different between Wistar rats and SHR. However, the percentage of cell surface occupied by dense plaques was increased in SHR, and the percentage of cell surface connected to the elastic lamellae was twice as high in SHR compared with Wistar rats (9.4+/-1.5% versus 3.8+/-1.1%). These results suggest that the elastin network plays a major role in the mechanical adaptation of the arterial wall in SHR, not through variations of its total amount but through variations of the extent of anchorage to the muscle cells.

Adaptation, Physiological↗

[Experimental study on erythrocyte of obstructive jaundice patient: its changes of membrane protein and mechanical properties].

The component of the erythrocyte membrane protein under three states obstruction, after surgical relief of obstruction, and normal) were analyzed qualitatively by using SDS-PAGE and the method of thin scanning. The result revealed that the membrane protein band 4.2 was absent under the state of obstruction and it recovered after surgical relief of obstruction. Then the mechanical properties of the above three cases of erythrocytes were tested by the micropipette aspiration system and the data were analyzed by Voigt model. The result showed that the elastic modulus and the coefficient of viscosity of the erythrocytes under the state of obstruction were greater than those of the normal; thus the deformability decreased, but "overcorrection" appeared after surgical relief of obstruction. The possible relations between the mechanical properties and the change of membrane protein were discussed.

Adult↗

Mechanical properties of dental luting cements.

STATEMENT OF PROBLEM: Dental luting cements fail by microcrack formation and bacterial ingress or by gross failure and crown dislodgment. Both of these failure modes are related to mechanical properties and deformation. PURPOSE: This study evaluated those mechanical properties of cements. METHODS AND MATERIAL. Elastic modulus for 8 representative cements (zinc phosphate, polycarboxylate, glass ionomer, encapsulated glass ionomer, resin-modified glass ionomer, resin composite, and adhesive resin composite) was measured by using a nondestructive technique and evaluated for cement type and storage time (1 hour, 1 day, 1 week, 1 month, 1 year) by 2-way ANOVA (P <.05). Compressive properties (proportional limit, resilience, and toughness), ultimate strengths (compressive, diametral tensile, and flexural), and flexural toughness were determined and evaluated by 2-way ANOVA for 2 crosshead testing rates (5 and 0.5 mm/min) and cement type (P <.05). RESULTS: Cements varied with respect to elastic moduli, compressive proportional limit, compressive resilience, compressive strength, compressive toughness, diametral tensile strength, flexural strength, and flexural toughness. Storage time affected the elastic moduli of different materials in different ways. Elastic moduli of polycarboxylate and glass ionomer cements increased over time, whereas the other materials changed little after the first day. Crosshead rate only significantly affected compressive proportional limit and resilience. CONCLUSIONS: Luting cements differed considerably with respect to mechanical properties.

Adhesives↗

The influence of different plasticizers and polymers on the mechanical and thermal properties, porosity and drug permeability of free shellac films.

The effect of triethyl citrate (TEC) and different molecular weights and concentrations of polyethylene glycol (PEG), in addition to the effect of different water-soluble polymers and dispersions at different levels, hydroxypropyl methylcellulose (HPMC), methylcellulose (MC), carbomer 940, polyvinyl alcohol (PVA), ethyl cellulose (EC), on the mechanical and thermal properties, drug permeability, and porosity of free shellac films were investigated. Shellac films were cast from aqueous solutions, and their mechanical properties were studied by tensile test. Thermal analyses were performed using differential scanning calorimetry (DSC). The results showed that the addition of plasticizer caused a decrease in both elastic modulus and glass transition temperature (T(g)) and an increase in elongation at break of free shellac films. This effect was related to the concentrations of plasticizers. Different molecular weights of PEGs have different plasticization mechanisms.Moreover, the incorporation of different amounts of HPMC, MC, or carbomer in free shellac films caused an increase in the flexibility, decrease in T(g), and a marked increase in drug permeability of free shellac films, whereas the addition of PVA caused a decrease in flexibility and drug permeability and an increase in T(g). Addition of EC resulted in a slight decrease of the elasticity and a small decrease in drug permeability. However it does not show a considerable effect on the T(g). In addition, it was found that the drug permeability is directly related to the mechanical properties and T(g) of shellac films.

Calorimetry, Differential Scanning↗