PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82Linked to original sources

Ascorbic acid biosensor using ascorbate oxidase immobilized on alkylamine glass beads.

A biosensor for ascorbic acid based on enzyme kinetics of ascorbate oxidase (E.C.1.10.3.3) was developed. The enzyme was extracted from Cucurbita maxima, or jerimun and immobilized by covalent bounding, using glutaradehyde as a bifunctional agent, on alkylamine glass beads, with and without enzyme active site protection. A low-cost, home-made oxygen electrode was applied as a transducer. The system has sensitivity from 62.5 up to 500 microM of ascorbic acid with satisfactory operation for more than 2 mo.

Alkylation↗

Surface plasmon resonance and biosensor technology for real-time molecular diagnosis of beta o 39 thalassemia mutation.

BACKGROUND: Biospecific interaction analysis (BIA) employing surface plasmon resonance (SPR) and biosensor technologies is of interest in clinical genetics. However, few data are available on its use in hereditary diseases caused by genetic mutations. AIM: The primary aim of this study was the refinement of BIA technology for use in identifying the beta o 39 mutation of the beta-globin gene, a mutation which causes a common type of beta o thalassemia. METHODS: Target-biotinylated PCR products were immobilized on streptavidin-coated sensor chips and diagnosed using SPR-based BIA performed by injecting specific oligonucleotide probes into the sensor chip. RESULTS: We demonstrated that the beta o 39 mutation can be easily and reproducibly identified during the association phase. CONCLUSIONS: This should be considered a pilot study demonstrating the ability of SPR-based BIA to detect point mutations in the beta-globin gene by real-time monitoring of hybridization between oligonucleotide probes and target-biotinylated PCR products generated from genomic DNA from normal, heterozygous individuals and homozygous beta o thalassemia patients.

Base Sequence↗

A disposable acetylcholinesterase-based electrode biosensor to detect anatoxin-a(s) in water.

Anatoxin-a(s) is a hazardous toxin released by cyanobacteria during bacterial blooms. A simple and fast method to detect this hazardous compound using a biosensor based on the electrochemical detection of the activity of acetylcholinesterase was developed. Among several acetylcholinesterases, electric eel enzyme was found to be the most sensitive to anatoxin-a(s) and was thus used to build disposable amperometric sensors. The system displayed a detection limit of 1 microg/L anatoxin-a(s). No unspecific effect was noticed with real water samples but spiked toxin was accurately detected. Oxime reactivation was used to discriminate between the toxin and potential insecticides present in the sample.

Acetylcholinesterase↗

Biosensors and flow-through system for the determination of creatinine in hemodialysate.

Biosensors for the determination of creatinine have been developed and integrated into a flow-through system. The sensors are based on a screen-printed three electrode transducer with a platinum working electrode. Applying the multi-enzyme sequence of creatininase (CA), creatinase (CI) and sarcosine oxidase (SO) hydrogen peroxide has been detected amperometrically. An optimal enzyme load was found to be 4.4 U/0.28 U/0.20 U (CA/CI/SO) and 0.28 U/0.20 U (CI/SO) per electrode for the creatinine sensor and for the creatine sensor, respectively. Among a variety of polymers Nafion has shown the highest efficiency to exclude interfering substances like ascorbic acid, acetaminophen and uric acid. First determinations of creatinine in dialysate samples obtained during hemodialysis treatments have shown a good correlation to the conventional methods, the Jaffé reaction (y=0.945x+ 2.8, R=0.9882, n=9) and the enzymatic photometric method (y=0.891x+3.5, R=0.9917, n=9).

Amidohydrolases↗

Pesticide toxicity assessment using an electrochemical biosensor with Pseudomonas putida and a bioluminescence inhibition assay with Vibrio fischeri.

Two different toxicity tests, an electrochemical biosensor Cellsense and a bioluminescence inhibition assay ToxAlert were performed in order to establish and compare the acute toxicity responses of different types of raw and spiked water for a selected group of pesticides. The selected compounds were endosulfan, chlorfenvinphos, dimethoate, fenamiphos, ametryn, deltamethrin and alpha-cypermethrin; all of them are used in large quantities for agricultural purposes. In the first step, the study of the toxicity responses for each individual pesticide with Milli-Q water was carried out. Next, the toxic responses of different mixtures of these pesticides in different water matrices, i.e., Milli-Q water, surface water, groundwater and wastewater were studied in order to evaluate (i) device advantages and limitations for the toxicity evaluation of real environmental samples, (ii) antagonistic or synergistic effects and (iii) the influence of the water matrices. The survey of pesticides in real samples was carried out using a combined method involving both chemical analysis and toxicity bioassays. Chemical analysis involved the use of solid-phase micro-extraction (SPME) followed by gas chromatography with electron capture detection (GC/ECD) or thermoionic specific detection (GC/TSD) with mass spectrometric confirmation (GC/MS).

Biosensing Techniques↗

Evaluation of the redox properties and anti/pro-oxidant effects of selected flavonoids by means of a DNA-based electrochemical biosensor.

Quercetin and rutin as well as catechin and epigallocatechin gallate were investigated, as widely distributed representatives of flavonols and flavanols, respectively, regarding their anti/pro-oxidant properties. The flavonoids are irreversibly oxidized at a dsDNA-modified screen-printed electrode within 0.368 to 0.449 V vs. SHE without binding to DNA. Using the DNA biosensor the detection scheme of a DNA prevention/degradation exploits the [Co(phen)(3)](3+) complex as an electrochemical DNA marker. Antioxidant activity of flavonoids was tested in a model cleavage mixture composed of 5 x 10(-7) mol L(-1) [Cu(phen)(2)](2+) as the catalyst, 1 x 10(-3) mol L(-1) ascorbic acid as the chemical reductant and atmospheric oxygen as the natural oxidant where reactive oxygen radicals are generated. The antioxidant activity increases with the concentration of flavonoids reaching a maximum where pro-oxidative behaviour becomes of importance. The pro-oxidant potency of flavonoids depends on the presence of atmospheric oxygen and follows the order quercetin>rutin>epigallocatechin gallate>catechin.

Antioxidants↗

Amperometric biosensor with HRP immobilized on a sandwiched nano-Au / polymerized m-phenylenediamine film and ferrocene mediator.

An amperometric biosensor has been developed for the determination of H(2)O(2) in plant samples. Horseradish peroxidase (HRP) is immobilized on a sandwiched nano-Au particle / m-phenylenediamine polymer film by glutaraldehyde cross-linking. The film is formulated on the carbon paste electrode (CPE) blended with ferrocene as an electron transfer mediator. On the low concentration range, the current response is related to the H(2)O(2) concentration linearly from 0 to 8x10(-6) M with a detection limit of 1.3x10(-7) M. On a wider concentration range of 8x10(-6) to 1.4x10(-4) M, the reciprocal of current response is linearly related to the reciprocal of H(2)O(2) concentration. The apparent Michaelis-Menten constant (K(m)(app)) was calculated to be 0.0334 mM. The sensor has been tested by determining H(2)O(2) concentration in plant leaf samples.

Biosensing Techniques↗

Array biosensor for detection of toxins.

The array biosensor is capable of detecting multiple targets rapidly and simultaneously on the surface of a single waveguide. Sandwich and competitive fluoroimmunoassays have been developed to detect high and low molecular weight toxins, respectively, in complex samples. Recognition molecules (usually antibodies) were first immobilized in specific locations on the waveguide and the resultant patterned array was used to interrogate up to 12 different samples for the presence of multiple different analytes. Upon binding of a fluorescent analyte or fluorescent immunocomplex, the pattern of fluorescent spots was detected using a CCD camera. Automated image analysis was used to determine a mean fluorescence value for each assay spot and to subtract the local background signal. The location of the spot and its mean fluorescence value were used to determine the toxin identity and concentration. Toxins were measured in clinical fluids, environmental samples and foods, with minimal sample preparation. Results are shown for rapid analyses of staphylococcal enterotoxin B, ricin, cholera toxin, botulinum toxoids, trinitrotoluene, and the mycotoxin fumonisin. Toxins were detected at levels as low as 0.5 ng mL(-1).

Biosensing Techniques↗

Are biosensor arrays in one membrane possible? A combination of multifrequency impedance measurements and chemometrics.

A novel concept of a membrane-based micro-array biosensor is presented. The methodology is based on a single lipid membrane interrogated with electrochemical impedance techniques followed by multivariate data analysis. A single membrane is designed so that relaxation processes with a range of time constants can be probed at different potentials. A range of other approaches cited in the literature is reviewed.

Biosensing Techniques↗

Biosensors based on electropolymerized films: new trends.

Electropolymerized films have received considerable attention in the development of biosensors and biochips, and are advancing rapidly. This paper reviews recent advances and scientific progress in electrochemical immobilization procedures for biological macromolecules on electrodes via electrogenerated polymer films. Biomolecule immobilization is classified as covalent linkage, attachment by affinity interactions, and physical entrapment. The last approach entails the use of conducting and non-conducting films, composite polymer films, and templates for the electropolymerization process. Some advances in the electrochemical transduction of biological events (enzymatic reaction, immunoreaction, or oligonucleotide hybridization) involving the redox properties or the conductivity of electropolymerized films are also presented.

Biosensing Techniques↗

Application of heated electrodes operating in a non-isothermal mode for interference elimination with amperometric biosensors.

Heated electrodes were applied for the non-isothermal operation of amperometric glucose biosensors based on glucose oxidase immobilised on the electrode surface by entrapment within a polymer layer. The localised deposition of the polymer film under simultaneous entrapment of the enzyme was achieved by an electrochemically induced pH-modulation in the diffusion zone in front of the electrode, thus altering the solubility of the polymer chains. This non-manual sensor preparation protocol could be successfully used for the modification of a novel indirectly heated electrode. The non-isothermal operating mode allows working at the optimum temperature of the enzyme sensors without any thermal distortion of the bulk solution. Increased surface temperature of the sensor thus accelerates transport as well as kinetic processes, resulting in an enhanced amperometric signal. In the presence of interfering compounds such as ascorbic acid, the proposed technique allows use of the diverging thermal impact on the sensing process, for different electrochemically active compounds, for a deconvolution of the amperometric signal at different electrode temperatures. A calculation method for determination of glucose in the presence of one interfering compound is presented as a basis for a calculative interference elimination.

Journal Article↗

Urease-glutamic dehydrogenase biosensor for screening heavy metals in water and soil samples.

A screen-printed three-electrode amperometric biosensor based on urease and the nicotinamide adenine dinucleotide hydrogen (NADH)-glutamic dehydrogenase system was developed and applied to the screening of heavy metals in environmental samples. The development of an amperometric sensor for the monitoring of urease activity was feasible by coupling the urea breakdown reaction catalysed by urease to the reductive ammination of ketoglutarate catalysed by glutamic dehydrogenase (GLDH). The ammonia provided by the urea conversion is required for the conversion of ketoglutarate to glutamate with the concomitant oxidation of the NADH cofactor. NADH oxidation is monitored amperometrically at 0.3 V (vs. Ag/AgCl) after urease immobilization onto the screen-printed three-electrode configuration. Immobilization of urease on the surface of screen-printed electrodes was performed by entrapment in alginate gel and adsorption on the electrode in a nafion film. Low sensitivity to inactivation by metals was recorded after urease entrapment in alginate gel with detection limits of 2.9 and 29.8 mg L(-1) for Hg(II) and Cu(II), respectively. The use of the negatively charged nafion film created a more concentrated environment of cations in proximity to the enzyme, thus enhancing the urease inhibition when compared to gel entrapment. The calculated detection limits were 63.6 and 55.3 microg L(-1) for Hg(II) and Cu(II), respectively, and 4.3 mg L(-1) for Cd(II). A significant urease inactivation was recorded in the presence of trace amounts of metals (microg L(-1)) when the enzyme was used free in solution. Analysis of water and soil samples with the developed nafion-based sensor produced inhibition on urease activity according to their metal contents. The obtained results were in agreement with the standard methods employed for sample analysis. Nevertheless, the use of the amperometric assay (with free urease) proved more feasible for the screening of trace amounts of metals in polluted samples.

Biosensing Techniques↗

Trends in the development of nucleic acid biosensors for medical diagnostics.

Some of the recent advances in the field of biosensors for nucleic acid analysis in medical diagnostic applications are highlighted. Particular attention is paid in this review to the progress made in two key areas of development: (i) enhancements achieved in device selectivity, and (ii) enhancements achieved in device sensitivity.

Biosensing Techniques↗

Biocomposites of covalently linked glucose oxidase on carbon nanotubes for glucose biosensor.

The formation of covalently linked composites of multi-walled carbon nanotubes (MWCNT) and glucose oxidase (GOD) with high-function density for use as a biosensing interface is described. The reaction intermediates and the final product were characterized by using FT-IR spectroscopy, and the MWCNT-coated GOD nanocomposites were examined by atomic force microscopy (AFM) and transmission electron microscopy (TEM). Interestingly, it was found that the GOD-MWCNT composites are highly water soluble. Electrochemical characterization of the GOD-MWCNT composites that were modified on a glassy carbon electrode shows that the covalently linked GOD retains its bioactivity and can specifically catalyze the oxidation of glucose. The oxidation current shows a linear dependence on the glucose concentration in the solution in the range of 0.5-40 mM with a detection limit of 30 microM and a detection sensitivity of 11.3 microA/mMcm2. The present method may provide a way to synthesize MWCNT related composites with other biomolecules and for the construction of enzymatic reaction-based biofuel cells and biosensors.

Biosensing Techniques↗

Sensitive detection of organophosphates in river water by means of a piezoelectric biosensor.

A highly sensitive piezoelectric biosensor has been developed for detection of cholinesterase inhibitors. The inhibitor benzoylecgonine-1,8-diamino-3,4-dioxaoctane (BZE-DADOO) was immobilized on a monolayer of 11-mercaptomonoundecanoic acid (MUA) self-assembled on the gold surface of the sensor. The binding of high-molecular-weight cholinesterase to the immobilized cocaine derivative was monitored with a mass sensitive piezoelectric quartz crystal (quartz crystal nanobalance; QCN). In the presence of an inhibiting substance in the sample, the binding of cholinesterase to the immobilized inhibitor was reduced. The decrease of the rate of mass change was proportional to the concentration of free inhibitor in the sample. This way the affinity sensor followed anti-cholinesterase toxicity and the enzyme activity of ChE was not addressed. A assay for detection of organophosphates (OP) was optimized. Regeneration of the sensor surface was achieved with 1 mol L(-1) formic acid, which enabled 40 measurements with one sensor. All assays were carried out in a flow-through arrangement. The total measurement time (binding+regeneration) was 25 min and the detection limit for different OP (paraoxon, diisopropylfluorophosphate, chlorpyriphos, and chlorfenvinphos) was down to 10(-10) mol L(-1) (0.02 microg L(-1)). This sensor was used for determination of organophosphate (diisopropylfluorophosphate) levels in river water samples.

Biosensing Techniques↗

Assay for uric acid level in rat striatum by a reagentless biosensor based on functionalized multi-wall carbon nanotubes with tin oxide.

A novel reagentless amperometric uric acid biosensor based on functionalized multi-wall carbon nanotubes (MWCNTs) with tin oxide (SnO2) nanoparticles has been developed. This was successfully applied to assay uric acid levels from an in vivo microdialysis sampling. Compared with unfunctionalized or traditional carboxylic acid (-COOH)-functionalized MWCNTs, the MWCNTs-SnO2 electrode exhibited higher electrocatalytic oxidation to uric acid. Here, MWCNTs-SnO2 may act as an efficient promoter, and the system exhibited a linear dependence on the uric acid concentration over the range from 1.0 x 10(-7) to 5.0 x 10(-4) mol L(-1). In addition, there was little ascorbic acid interference. The high sensitivity of the MWCNTs-SnO2 modified enzyme electrode enabled the monitoring of trace levels of uric acid in dialysate samples in rat striatum.

Animals↗

Fabrication of cell-containing hydrogel microstructures inside microfluidic devices that can be used as cell-based biosensors.

This paper describes microfluidic systems containing immobilized hydrogel-encapsulated mammalian cells that can be used as cell-based biosensors. Mammalian cells were encapsulated in three-dimensional poly(ethylene glycol)(PEG) hydrogel microstructures which were photolithographically polymerized in microfluidic devices and grown under static culture conditions. The encapsulated cells remained viable for a week and were able to carry out enzymatic reactions inside the microfluidic devices. Cytotoxicity assays proved that small molecular weight toxins such as sodium azide could easily diffuse into the hydrogel microstructures and kill the encapsulated cells, which resulted in decreased viability. Furthermore, heterogeneous hydrogel microstructures encapsulating two different phenotypes in discrete spatial locations were also successfully fabricated inside microchannels.

3T3 Cells↗

Electrocatalytic reduction of hydrogen peroxide on modified graphite electrodes: application to the development of glucose biosensors.

The electrocatalytic activities of a series of compact graphites modified with microquantities of platinum metals (Pd or Pt+Pd) towards the electrochemical reduction of hydrogen peroxide were characterised. Operational parameters such as the optimal working potential, the influence of temperature and the resulting electrode characteristics were examined. The benefits of using graphite modified with Pt+Pd (mixture ratio 30%:70%) as the basic transducer in a glucose biosensor with improved sensitivity were demonstrated. It was proven that, under the working conditions chosen, the selected electrode (whether bare or covered with an enzyme layer) did not respond to any glutathione, uric acid or ascorbic acid (which all normally occur in biological fluids) present.

Biosensing Techniques↗