PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microchip Analytical Procedures”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Towards microalbuminuria determination on a disposable diagnostic microchip with integrated fluorescence detection based on thin-film organic light emitting diodes.

As a first step towards a fully disposable stand-alone diagnostic microchip for determination of urinary human serum albumin (HSA), we report the use of a thin-film organic light emitting diode (OLED) as an excitation source for microscale fluorescence detection. The OLED has a peak emission wavelength of 540 nm, is simple to fabricate on flexible or rigid substrates, and operates at drive voltages below 10 V. In a fluorescence assay, HSA is reacted with Albumin Blue 580, generating a strong emission at 620 nm when excited with the OLED. Filter-less discrimination between excitation light and generated fluorescence is achieved through an orthogonal detection geometry. When the assay is performed in 800 microm deep and 800 microm wide microchannels on a poly(dimethylsiloxane)(PDMS) microchip at flow rates of 20 microL min(-1), HSA concentrations down to 10 mg L(-1) can be detected with a linear range from 10 to 100 mg L(-1). This sensitivity is sufficient for the determination of microalbuminuria (MAU), an increased urinary albumin excretion indicative of renal disease (clinical cut-off levels: 15-40 mg L(-1)).

Albuminuria↗

A resistive-pulse sensor chip for multianalyte immunoassays.

MultiAnalyte immunoassays are often required to diagnose a pathologic condition. Here, we show how resistive-pulse sensing and multiple artificial pores can be integrated together on a single chip to detect different antigens rapidly and simultaneously. We use multiple pores on a single chip to detect the size change of latex colloids upon specific antigen-antibody binding on the colloid surface. As a proof-of-principle, we demonstrate our ability to detect simultaneously human G-CSF and GM-CSF antigens on a single chip. Our novel technique is a scalable technology that can lead to the sensing of at least N2 antigens simultaneously with an N N array of pores on a single chip.

Antigen-Antibody Reactions↗

A microfluidic device using a green organic light emitting diode as an integrated excitation source.

A simply fabricated microfluidic device using a green organic light emitting diode (OLED) and thin film interference filter as integrated excitation source is presented and applied to fluorescence detection of proteins. A layer-by-layer compact system consisting of glass/PDMS microchip, pinhole, excitation filter and OLED is designed and equipped with a coaxial optical fiber and for fluorescence detection a 300 microm thick excitation filter is employed for eliminating nearly 80% of the unwanted light emitted by OLEDs which has overlaped with the fluorescence spectrum of the dyes. The distance between OLED illuminant and microchannels is limited to approximately 1 mm for sensitive detection. The achieved fluorescence signal of 300 microM Rhodamine 6G is about 13 times as high as that without the excitation filter and 3.5 times the result of a perpendicular detection structure. This system has been used for fluorescence detection of Rhodamine 6G, Alexa 532 and BSA conjugates in 4% linear polyacrymide (LPA) buffer (in 1 x TBE, pH 8.3) and 1.4 fmol and 35 fmol mass detection limits at 0.7 nl injection volume for Alexa and Rhodamine dye have been obtained, respectively.

Acrylic Resins↗

A lab-on-a-chip for spectrophotometric analysis of biological fluids.

This paper reports a lab-on-a-chip for application in clinical analysis, especially in the spectrophotometric analysis of biological fluids. It is composed of three parts: (1) a microfluidic system die containing the microchannels fabricated using SU-8 techniques; (2) an optical filtering system based on highly selective Fabry-Perot optical resonators using a stack of CMOS process compatible thin-film layers; (3) a detection and readout system fabricated in a CMOS microelectronic process. The system enables low-cost and selective measurement of the concentration of several biomolecules in biological fluids. Operation is based on optical absorption in a well-defined part of the visible spectrum, defined by the reaction of a specific reagent with a specific biomolecule. Signals proportional to the intensity of the light transmitted through the biological fluid are available at the output in the form of bit streams, which allows simple computer interfacing. Moreover, the optical filtering system enables the measurement using white light illumination, thus avoiding the use of a wavelength dependent light source. This characteristic makes the lab-on-a-chip portable and ensures that the analysis can be performed at any location with instantaneous results, without the use of complex and expensive analysis systems. The quantitative measurement of uric acid and total protein in urine is demonstrated.

Body Fluids↗

Extraction of pure cellular fluorescence by cell scanning in a single-cell microchip.

A 3-dimensional liquid flow control method has been developed to manipulate and retain a single yeast cell freely in a microchip. This method allows us to carry out single-cell experiments by selecting any desired single cell from a group, retaining the cell for cellular signal detection, and delivering reagents to the cell during continual detection and observation without any negative impact from the liquid flow on the live cell. The cell was scanned back and forth across an observation window in order to extract pure cellular fluorescent signals. Different scanning methods were discussed for effective collection of the cellular fluorescent signal. The cell scanning technique results in many advantages, such as distinguishing a small part of a cell, allowing for background correction and monitoring the switch of reagents. In addition, it is possible to evaluate the photobleaching effects on both the background and cellular fluorescence, with the latter found to be less significant in a restricted cellular environment.

Fluorescence↗

Development and optimization of a lab-on-a-chip device for the measurement of trace nitrogen dioxide gas in the atmosphere.

We propose the use of lab-on-a-chip technology for measuring gaseous chemical pollutants, and describe the development of a microchip for the detection of nitrogen dioxide (NO2) in air. A microchip fabricated from quartz glass has been developed for handling the following three functions, gas absorption, chemical reaction and fluorescence detection. Channels constructed in the microchip were covered with porous glass plates, allowing nitrogen dioxide to penetrate into the triethanolamine (TEA) flowing within the microchannel beneath. The nitrogen dioxide was then mixed with TEA and reacted with a suitable fluorescence reagent in the chemical reaction chamber in the microchip. The reacted solution was then allowed to flow into the fluorescence detection area to be excited by an ultraviolet light-emitting diode (UV-LED), and the fluorescence was detected using a photomultiplier tube (PMT). The reaction time, reagent concentration, pH, flow rate and other measurement conditions were optimised for analysis of nitrogen dioxide in air. Preliminary studies with standardized test solutions revealed quantitative measurements of nitrite ion (NO2-), which corresponded to atmospheric nitrogen dioxide in the range of 10-80 ppbv.

Air Pollutants↗

Fabrication of poly(methyl methacrylate) capillary electrophoresis microchips by in situ surface polymerization.

A novel method based on in situ surface polymerization of methyl methacrylate (MMA) has been developed for the rapid fabrication of poly(methyl methacrylate) (PMMA) capillary electrophoresis (CE) microchips. MMA containing both thermal and ultraviolet (UV) initiators was allowed to prepolymerize in a water bath to form a fast curing molding solution that was subsequently sandwiched between a nickel template and a PMMA plate. The images of the raised microchannels on the nickel template were precisely replicated into the synthesized PMMA substrates during the UV-initiated polymerization of the molding solution within 30 min under ambient temperature. The attractive performances of the novel PMMA microchips have been demonstrated in connection with amperometric detection for the separation and detection of several model analytes. The new approach significantly simplifies the process for fabricating PMMA devices and could be applied to other materials that undergo light-initiated polymerization.

Electrophoresis, Capillary↗

Simulating molecular shuttle movements: towards computer-aided design of nanoscale transport systems.

Molecular shuttles based on the motor protein kinesin and microtubule filaments have the potential to extend the lab-on-a-chip paradigm to nanofluidics by enabling the active, directed and selective transport of molecules and nanoparticles. Based on experimentally determined parameters, in particular the trajectory persistence length of a microtubule gliding on surface-adhered kinesin motors, we developed a Monte-Carlo simulation, which models the transport properties of guiding structures, such as channels, rectifiers and concentrators, and reproduces the properties of several experimentally realized systems. Our tool facilitates the rational design of individual guiding structures as well as whole networks, and can be adapted to the simulation of other nanoscale transport systems.

Computer Simulation↗

Supercooled micro flows and application for asymmetric synthesis.

Supercooled micro flow in microchannels was demonstrated. In order to clarify fundamental properties of the supercooling state in microchannels, freezing temperature was measured in the microchannels having widths ranging from 70 microm to 300 microm. The freezing temperature decreased with decreasing width of the microchannel when the microchannel wall was chemically modified with octadecylsilane group. The lowest freezing temperature was observed as -28 degrees C for water in the 70 microm wide microchannel. By contrast, the freezing temperature was -15 degrees C and did not depend on width when a microchannel with a bare glass surface was used. Next, the freezing point was measured with flow rates ranging from 0.1 to 2.0 microl min(-1) and no dependence on flow rate was observed. Then, the supercooled micro flow was applied to an asymmetric reaction in micro two-phase flow of aqueous and CH2Cl2 phases. As expected from thermodynamic prediction, enantiomeric selectivity increased in the supercooled state of water.

Catalysis↗

Development of a respirometric biochip for embryo assessment.

A prototype respirometric biochip dedicated to monitoring oxygen consumption of preimplantation embryos has been developed. The biochip comprises a linear array of eight flow-through microchambers profiled on silicon substrate, and functions together with a phosphorescent oxygen sensitive probe and fluorescence plate reader detection. A high level of sensitivity to changes in dissolved oxygen was achieved through miniaturisation and optimization of biochip geometry, and incorporation of appropriate sealing and humidification systems. The biochips have allowed characterisation of oxygen consumption, by 2 cell and blastocyst stage preimplantation mouse embryos, through monitoring as few as ten preimplantation embryos over a one-hour time period. They provide a non-invasive, simple and convenient means for assessing preimplantation embryo metabolism.

Animals↗

Proteome-on-a-chip: mirage, or on the horizon?

Proteomics has emerged as the next great scientific challenge in the post-genome era. But even the most basic form of proteomics, proteome profiling, i.e., identifying all of the proteins expressed in a given sample, has proven to be a demanding task. The proteome presents unique analytical challenges, including significant molecular diversity, an extremely wide concentration range, and a tendency to adsorb to solid surfaces. Microfluidics has been touted as being a useful tool for developing new methods to solve complex analytical challenges, and, as such, seems a natural fit for application to proteome profiling. In this review, we summarize the recent progress in the field of microfluidics in four key areas related to this application: chemical processing, sample preconcentration and cleanup, chemical separations, and interfaces with mass spectrometry. We identify the bright spots and challenges for the marriage of microfluidics and proteomics, and speculate on the outlook for progress.

Animals↗

A modular microfluidic architecture for integrated biochemical analysis.

Microfluidic laboratory-on-a-chip (LOC) systems based on a modular architecture are presented. The architecture is conceptualized on two levels: a single-chip level and a multiple-chip module (MCM) system level. At the individual chip level, a multilayer approach segregates components belonging to two fundamental categories: passive fluidic components (channels and reaction chambers) and active electromechanical control structures (sensors and actuators). This distinction is explicitly made to simplify the development process and minimize cost. Components belonging to these two categories are built separately on different physical layers and can communicate fluidically via cross-layer interconnects. The chip that hosts the electromechanical control structures is called the microfluidic breadboard (FBB). A single LOC module is constructed by attaching a chip comprised of a custom arrangement of fluid routing channels and reactors (passive chip) to the FBB. Many different LOC functions can be achieved by using different passive chips on an FBB with a standard resource configuration. Multiple modules can be interconnected to form a larger LOC system (MCM level). We demonstrated the utility of this architecture by developing systems for two separate biochemical applications: one for detection of protein markers of cancer and another for detection of metal ions. In the first case, free prostate-specific antigen was detected at 500 aM concentration by using a nanoparticle-based bio-bar-code protocol on a parallel MCM system. In the second case, we used a DNAzyme-based biosensor to identify the presence of Pb(2+) (lead) at a sensitivity of 500 nM in <1 nl of solution.

Biochemistry↗

Microfluidic gas-flow profiling using remote-detection NMR.

We have used nuclear magnetic resonance (NMR) to obtain spatially and temporally resolved profiles of gas flow in microfluidic devices. Remote detection of the NMR signal both overcomes the sensitivity limitation of NMR and enables time-of-flight measurement in addition to spatially resolved imaging. Thus, detailed insight is gained into the effects of flow, diffusion, and mixing in specific geometries. The ability for noninvasive measurement of microfluidic flow, without the introduction of foreign tracer particles, is unique to this approach and is important for the design and operation of microfluidic devices. Although here we demonstrate an application to gas flow, extension to liquids, which have higher density, is implicit.

Diffusion↗

Piezo- and solenoid valve-based liquid dispensing for miniaturized assays.

Miniaturization of biological assays requires dispensing liquids in the submicroliter range of volumes. Accuracy and reproducibility of dispensing this range depend on both the dispenser and the receptacle in which the assay is constructed. Miniaturization technologies developed by Aurora Discovery, Inc. (San Diego, CA) include high-density multiwell plates for assay samples and reagent storage, as well as piezo-based and solenoid valve-based liquid dispensers. Some basic principles of small-volume dispensing by jetting are described to provide context for dispenser design and function. Performance of the latest instruments incorporating these dispensing devices is presented.

Biological Assay↗