PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Resolution”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90Linked to original sources

Epoxy-resin injection of the cerebral arterial microvasculature: An evaluation of the limits of spatial resolution in 8 Tesla MRI.

The purpose of this study was to quantify the spatial resolution of microscopic arteries on magnetic resonance images acquired at 8 Tesla (T). Techniques similar to those used for standard MRI of the human brain in vivo at 8 T were utilized to generate high-resolution gradient echo (GE) images of a whole postmortem human brain whose common carotid arterial system had been injected with an epoxy-resin. Single slice images, along with summed images of up to 5 contiguous slices, were then compared to color digital photographs detailing the distribution of the arterial system on the surface of the same injected brain. There was excellent MR visualization of the microscopic cerebral arteries down to a spatial resolution of 200 microm. Through the use of an 8 T whole-body MRI scanner and standard GE imaging sequences, microscopic arterial structures can be clearly resolved down to a dimension of 200 microm.

Aged↗

Facile optical resolution of tert-butanethiosulfinate by molecular complexation with (R)-BINOL and study of chiral discrimination of the diastereomeric complexes.

An important synthon, tert-butanethiosulfinate (2), has been effectively resolved by forming molecular complexes with (R)-2,2'-dihydroxy-1,1'-binaphthyl (BINOL, 3) in high enantioselectivity (>99 % ee). The present procedure represents the first example of the resolution of thiosulfinate. The mechanism of chiral discrimination is discussed in terms of molecular recognition based on IR and Xray analyses of the diastereomeric complexes during the resolution. In the less-soluble complex, (R)-3 and (R)-2 self-assembled as a linear supramolecule; however, in the more-soluble complex, (R)-3 and (S)-2 formed a simple bimolecular complex by one stronger hydrogen bond. Hydrogen bonding is the major driving force for effective resolution.

Crystallography↗

New high-resolution 2-deoxyglucose method featuring double labeling and automated data collection.

A new approach to high-resolution 2-deoxy-D-glucose (2DG) emulsion-autoradiography which combines improved retention of 2DG labeling, staining with immunohistochemical and other specific markers, and automated data collection and analysis of local silver grain and stain densities is described. The Durham et al. (J. Neurosci. 1:519-526, '81) procedure for fixation of 2DG with periodate-lysine-paraformaldehyde (PLP, McLean and Nakane: J. Histochem. Cytochem. 22:1077-1083, '74) was adapted to increase retained label roughly tenfold. Phenobarbital anesthesia is induced 45 minutes after 2DG injection. Barbiturate anesthesia increases brain glycogen (Nelson et al.: J. Neurochem. 15:1271-1279, '68) and presumably increases the incorporation of intracellular 2DG from 2DG-6P into brain glycogen and other molecules (Nelson et al.: J. Neurochem. 43:949-956, '84; Pentreath et al.: Neuroscience 7:759-767, '82). Iodoacetate is added to cold fixative to prevent glycogen breakdown (Cammermeyer and Fenton: Histochemistry 76:339-356, '82). This high-resolution 2DG protocol is directly compatible with many other neuroanatomical techniques. We demonstrate 2DG emulsion autoradiography combined with cytochrome oxidase (CO) histochemistry, markers for axonal pathway tracing, plastic embedding for semithin sections, and immunohistochemical staining for glutamate decarboxylase (GAD). The method should be compatible with antibodies for other antigens and with other neuroanatomical stains. To collect the data directly from microscope slides, a computer-controlled microscope was integrated with image-processing software to eliminate the need for manual counting and scoring of autoradiograms. Regions of interest are scanned automatically at high resolution to map regional labeling and/or stain density. There is excellent correspondence between computer-enhanced two-dimensional maps of the data and the original autoradiograms. Automated counts for five specimens were compared to counts of labeled cells by trained observer. The correlation between the two sets of measurements is high (r = .93). Automated data collection has been generalized to measure regional stain densities on the autoradiographed sections for direct comparison with silver grain density. The method is extremely flexible, especially since new image-processing strategies can be developed in software to extract the desired information from materials labeled by other methods (e.g., HRP).(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

Flow cytometric S-phase fraction measurement in breast carcinoma: Influence of software and histogram resolution.

BACKGROUND: S-phase fraction (SPF) measurement by flow cytometry is a clinically useful prognostic factor in patients with breast carcinoma. Standardized SPF determination is essential. As part of a multicenter study, we evaluated the influence of the choice of software and histogram resolution (256, 512, or 1,024 channels) on SPF quantification. METHODS: One hundred thirty-three DNA histograms were analyzed in three laboratories with Modfit 5.2, Modfit LT, and Multicycle AV software. Strict rules for histogram interpretation and software management were applied. The following five options were compared: MF 5.2 1024, MF 5.2 256, MF LT 256, MC AV 256, and MC AV 512. RESULTS: In the DNA diploid and aneuploid groups, SPF distributions were not statistically different among the five options. Excellent quantitative correlations were obtained between pairs of options. When using tertiles as cutpoints for SPF classification, concordance rates ranged from 79.7% to 93.2% for DNA diploid samples and from 87.8% to 95.9% for DNA aneuploid samples, the best results being obtained with software working with a similar histogram resolution. CONCLUSIONS: Standardized use of commercially available software, including the choice of histogram resolution, provides comparable SPF results.

Breast Neoplasms↗

Construction and application of a full-coverage, high-resolution, human chromosome 8q genomic microarray for comparative genomic hybridization.

BACKGROUND: Array-based comparative genomic hybridization (aCGH) enables genome-wide quantitative delineation of genomic imbalances. A high-resolution contig array was developed specifically for chromosome 8q because this chromosome arm is frequently altered in many human cancers. METHODS: A minimal tiling path contig of 702 8q-specific bacterial artificial chromosome (BAC) clones was generated with a novel computational tool (BAC Contig Assembler). BAC clones were amplified by degenerative oligonucleotide primer (DOP) polymerase chain reaction and subsequently printed onto glass slides. For validation of the array DNA samples of gastroesophageal and prostate cancer cell lines, and chronic myeloid leukemia specimens were used, which were previously characterized by multicolor fluorescence in situ hybridization and conventional CGH. RESULTS: Single and double copy gains were confidently demonstrated with the 8q array. Single copy loss and high-level amplifications were accurately detected and confirmed by bicolor fluorescence in situ hybridization experiments. The 8q array was further tested with paraffin-embedded prostate cancer specimens. In these archival specimens, the copy number changes were confirmed. In fresh and archival samples, additional alterations were disclosed. In comparison with conventional CGH, the resolution of the detected changes was much improved, which was demonstrated by an amplicon of 0.7 Mb and a deletion of 0.6 Mb, both spanned by only six BAC clones. CONCLUSIONS: A comprehensive array is presented, which provides a high-resolution method for mapping copy number alterations on chromosome 8q.

Adenocarcinoma↗

Single particle high resolution spectral analysis flow cytometry.

BACKGROUND: While conventional multiparameter flow cytometers have proven highly successful, there are several types of analytical measurements that would benefit from a more comprehensive and flexible approach to spectral analysis including, but certainly not limited to spectral deconvolution of overlapping emission spectra, fluorescence resonance energy transfer measurements, metachromic dye analysis, free versus bound dye resolution, and Raman spectroscopy. METHODS: Our system utilizes a diffraction grating to disperse the collected fluorescence and side-scattered light from cells or microspheres passing through the interrogation region over a rectangular charge-coupled-device image sensor. The flow cell and collection optics are taken from a conventional flow cytometer with minimal modifications to assure modularity of the system. RESULTS: Calibration of the prototype spectral analysis flow cytometer included wavelength characterization and calibration of the dispersive optics. Benchmarking of the system demonstrated a single particle/cell intensity sensitivity of 2160 MESF of R-Phycoerythrin. Single particle spectra taken with our instrument were validated against bulk solution fluorimeter and conventional flow cytometer measurements. Coefficients of variation of integrated spectral fluorescence intensity of several sets of standard fluorescent microspheres ranged from 1.4 to 4.8% on the spectral system. Spectral discrimination of free versus PI bound to cells is also demonstrated. CONCLUSIONS: It is demonstrated that the flow spectrometer has sufficient sensitivity and wavelength resolution to detect single cells and microspheres, including multi-fluorophore labeled microspheres. The capability to use both standard mathematical deconvolution techniques for data analysis, coupled with the feasibility of integration with existing flow cytometers, will improve the accuracy and precision of ratiometric measurements, enable the analysis of more discrete emission bands within a given wavelength range, and allow more precise resolution of the relative contribution of individual fluorophores in multiply-tagged samples, thereby enabling a range of new applications involving the spectral analysis of single cells and particles.

Calibration↗

High resolution scanning of DNA autoradiographs.

The sizes of DNA fragments (alleles) on autoradiographs are measured by means of a computerised video scanner developed in this laboratory. This report investigates the advantages of using higher resolution equipment for this purpose. High resolution is simulated by using existing equipment and moving the video camera closer to the autoradiograph. Test autoradiographs, used to validate the original scanner, have been rescanned to determine the degree of improvement that could be obtained using expensive high resolution equipment.

Alleles↗

Electrophoretic conditions for high resolution citrus isozymes in polyacrylamide gel electrophoresis.

Electrophoretic conditions including electrode and gel buffers, acrylamide concentration, use of stacking gels, voltage, current, and run time were investigated in order to produce isozyme bands of high resolution which would facilitate densitometric quantification of enzyme activity following polyacrylamide gel electrophoresis (PAGE). Electrode buffers which provided optimal conditions for gels stained for the isozymes of malate dehydrogenase (MDH), 6-phosphogluconate dehydrogenase (6-PGD), phosphoglucose isomerase (PGI), and shikimate dehydrogenase (SkDH) were 0.02 M Tris-glycine, pH 8.5, 0.1 M sodium borate, pH 6.0, 0.1 M sodium borate, pH 8.7, and 0.07 M sodium borate, pH 7.0, respectively. A 0.5 M Tris-HCl, pH 7.5, gel buffer was optimal for gels stained for the isozymes of 6-PGD, PGI and SkDH. A 0.5 M Tris-HCl, pH 8.5, gel buffer was best for gels stained for MDH. Stacking gels were found to be detrimental to enzyme activity and showed no improvement in resolution for any of the enzymes. Acrylamide concentration for gels stained for MDH were 8.7%, gels stained for 6-PGD and PGI were 7.5%, while gels stained for SkDH had an acrylamide concentration of 5.0%. Higher concentrations above these levels caused a reduction and in some cases loss of band activity, while below this concentration there was a decrease in band resolution.(ABSTRACT TRUNCATED AT 250 WORDS)

Alcohol Oxidoreductases↗

Electrophoretic resolution versus fluctuations of the lateral dimensions of a capillary.

Because the local electrical resistance is inversely proportional to the local cross-section of a capillary, the intensity of the electric field varies along the migration path if the inner diameter of the capillary is not constant. Therefore, fluctuations of the lateral dimensions of a capillary can directly affect the net elution time as well as the peak width, and, hence the final resolution. In this article, we develop the theoretical framework for the study of such effects. We then examine the simple case where both the mobility and the diffusion coefficient are field-independent; in particular, we demonstrate that resolution can be severely reduced if the inner walls are not flat, and that optimal resolution is always obtained for perfectly flat walls. Generalized to ultrathin gels, our results clearly indicate that both random and systematic variations of the gel thickness can greatly affect the performance of the separation process. Acceptable degrees of flatness are estimated for both geometries. This study thus provides a quantitative understanding of the type of quality control one requires to obtain optimal results with capillaries and ultrathin gels.

Electrophoresis↗

A comparison of resolution of DNA fragments between agarose gel and capillary zone electrophoresis in agarose solutions.

The resolving power of capillary zone electrophoresis (CZE) is compared to that of gel electrophoresis (GE) under similar conditions (agarose, similar length of DNA fragments, identical buffer) but with differences in temperature and field strength. The comparison is based on the time required to reach a desired degree of resolution by each of the two methods. A resolution parameter is developed which is equally applicable to CZE, with relatively diffuse initial conditions in the absence of stacking and measurements expressed in terms of time, and to GE, in which measurements are expressed in terms of spatial parameters. The resolution time in CZE using agarose solutions at 40 degrees C was found to be greater by at least one order of magnitude than that in GE using agarose gels. Thus, the increased migration velocity due to high field strength in CZE substantially outweighs the lower dispersion in GE.

DNA↗

Capillary electrophoretic resolution of phosphorylated peptide isomers using micellar solutions and coated capillaries.

The addition of sodium dodecyl sulfate (SDS) micelles in the running buffer can be used to resolve mono- and diphosphorylated isomers of the insulin receptor peptide by capillary electrophoresis. The effect of SDS on peptide resolution is very dependent on pH. Complete resolution of three monophosphorylated isomers is achieved in uncoated capillaries filled with phosphate buffer containing 25 mM SDS and buffered at pH 6.1. Resolution of the diphosphorylated isomers can be significantly improved by using polyacrylamide coated capillaries. In coated capillaries electroosmotic flow is negligible and the migration order of the isomers is reversed. This allows for a longer period of interaction between the diphosphorylated isomers and the micelle and therefore selectivity is improved. Efficiency of all peptide isomers was also improved in coated capillaries due to reduced adsorption to the capillary wall.

Acrylic Resins↗

Application of gels of 0.5 mm thickness to electrophoresis in the automated HPGE-1000 apparatus: improved resolution.

Gel electrophoresis in commercial automated apparatus (HPGE-1000, LabIntelligence, Menlo Park, CA) is conventially conducted in gels of 3 mm thickness at about 15 V/cm. Since the intermittent scanning of the gel allows one to measure band width as a function of migration time, resolution may be evaluated quantitatively. Comparing the value of resolution between two proteins in electrophoresis on agarose gels of 0.5 and 3.0 mm thickness and at various field strengths, it was found that within the given Joule heat dissipation capacity of the apparatus, resolution between the proteins is improved when the gel thickness is reduced from 3.0 to 0.5 mm, which allows for an increase in field strength from 15 V/cm, conventional for that apparatus, to 45 V/cm.

Autoanalysis↗

The influence of buffer composition on separation efficiency and resolution in capillary electrophoresis of 8-aminonaphthalene-1,3,6-trisulfonic acid labeled monosaccharides and complex carbohydrates.

The effect of buffer conditions -- varying in salt type, pH, and concentration -- on the separation of 8-aminonaphthalene-1,3,6-trisulfonic acid (ANTS)-labeled monosaccharides and complex-type carbohydrates was investigated. Different buffer systems for high and low electroosmotic flow conditions were chosen: a phosphate and a citrate background electrolyte, each at pH 2.5, a phosphate buffer, pH 9.0, and a borate buffer at pH 9.5. All buffer systems displayed differences in resolution and selectivity. Phosphate and borate buffer demonstrated the greatest selectivity changes for ANTS-labeled carbohydrates. While separation in the phosphate system relies mainly on differences in the charge-to-mass-ratio, additional selectivity can be achieved with borate complexation of glycoconjugates. The use of borate buffers improved monosaccharide separations whereas complex carbohydrates showed a loss in resolution. The citrate background electrolyte at low pH caused no significant changes in the separation performance. The pH 9.0 phosphate buffer showed a reversed migration order of the ANTS conjugates with a decreased resolution, compared to the pH 2.5 phosphate buffer, due to the strong electroosmotic flow generated under high pH conditions. An ovalbumin-derived oligosaccharide library demonstrates the significance of buffer selectivity for complex carbohydrate separations. The separation in the acidic phosphate and the alkaline borate buffer generates a different pattern and only the combination of both buffer systems allows an appropriate assessment of sample complexity.

Acids↗

High resolution slab gel electrophoresis of 8-amino-1,3, 6-pyrenetrisulfonic acid (APTS) tagged oligosaccharides using a DNA sequencer.

A novel electrophoretic method for the analysis of oligosaccharides using DNA sequencer technology is illustrated using malto-oligosaccharide distributions obtained following isoamylase digestion of glycogen, wheat starch and potato starch. The debranched starches were derivatized at the reducing and with the charged fluorophore 8-amino-1,3,6-pyrenetrisulfonic acid (APTS). This highly reproducible method provides baseline resolution of oligomers from chain lengths of 3 to more than 80 glucose units, and exhibits high sensitivity with detection thresholds of one femtomole per resolved band. In addition, the reductive amination procedure attaches a single fluorophore per oligosaccharide, allowing calculation of the results on either a mass or a molar basis. The efficacy of the method is illustrated through the determination of the profile of individual oligosaccharides of chain length with a degree of polymerization (DP) < 80, derived from loading less than 15 ng per analysis of glycogen, wheat and potato starches. While the results obtained were superior in resolution and sensitivity to previously reported observations using a range of techniques, they were nonetheless consistent with the overall differences between these polysaccharides. The resolution, sensitivity, reproducibility and high throughput of the method provides substantial advantages over existing methods for the analysis of linear oligosaccharide chain length distributions.

Amination↗

Enhancement of resolution of low molecular weight RNA profiles by staircase electrophoresis.

Stable low molecular weight (LMW) RNA comprises molecules used in the taxonomy of microorganisms and in studies on the microbial diversity of populations. However, the use of electrophoretic techniques has been hampered due to the low resolution obtained with techniques used for the separation of this kind of molecule. In this work we develop an electrophoretic method (staircase electrophoresis) that increases the resolution of the technique. This improvement in the resolution adequately resolves the three zones that integrate the profiles of LMW RNA: ribosomic 5S RNA (5S rRNA), class 2 transfer RNA (tRNA), and class 1 transfer RNA, allowing the technique to be applied to taxonomic studies (diagnostic, the identification of the individuals), phylogenetic studies and studies on naturally occurring microbial populations.

Electrophoresis↗

Some properties of a measure of resolution in gel electrophoresis and capillary zone electrophoresis.

The most commonly used measure of resolution for chromatographic and electrophoretic separations does not take into account the possibility of there being different amounts of each of the molecular species. A modification of a measure of resolution recently suggested by Aldroubi and Garner (BioTechniques 1992, 13, 620-624) can incorporate this effect explicitly. Their criterion for resolution is based on the time to observe a valley of specified magnitude separating two peaks. We examine how this measure depends on different physically relevant parameters that characterize the system.

DNA↗

Towards predicting mobility and resolution in polymeric media: some first steps.

Particle size-dependent retardation ("molecular sieving") in electrophoresis can be achieved in polymer solutions or gels. In the semidilute concentration range of polymer solutions, mobility of "rigid, spherical" particles can be predicted from their size (in the size range less than 20 nm radius), the screening length specific for the particular polymer and a constant that can be experimentally determined for a polymer. That constant could be universal for all hydrophilic uncharged polymers. Band spreading in polymer solutions is constant over a range of particle sizes and polymer concentrations and increases beyond that range. Presumably, the critical division between the two ranges occurs when the diameter of the particle exceeds the screening length of the polymer network. Resolution, defined as separation divided by the sum of bandwidths, can thus be predicted for a limited particle size and polymer concentration range. In gels, resolution can be estimated from the slopes and free mobility intercepts of the Ferguson plot. However, the previous computation of resolution needs to be revised in view of the fact that band spreading in gels proceeds in proportion to time, presumably through interaction with the polymer, and not as a function of the square root of time as would be the case if band spreading resulted from diffusion.

Diffusion↗

High-resolution single-stranded DNA analysis on 4.5 cm plastic electrophoretic microchannels.

Plastic microchannels (4.5 cm long) fabricated from an etched glass master were tested for high-resolution single-stranded DNA analysis. Using replaceable denaturing linear polyacrylamide as sieving matrix, one-color separation of a fragment sizing standard with single-base resolution (R > 0.5) was achieved up to 275 bases. Two-color sizing analysis of four loci short tandem repeat (STR) allelic ladder (CSF1PO, TPOX, TH01, vWA) with single-base resolution (R = 0.62) on TH01 alleles 9.3 (198 bp) and 10 (199 bp) was demonstrated. An average standard deviation of +/- 0.06 bp and +/-0.11 bp in sizing 32 alleles of the CTTv ladder was attained between runs and between channels, respectively. Four-color sequencing separation of a terminator sequencing standard showed a base-calling accuracy of 99.1% out to 320 bases in 13 min.

Acrylic Resins↗