Interaction of daunomycin antibiotic with human serum albumin: investigation by resonant mirror biosensor technique, fluorescence spectroscopy and molecular modeling methods.

Daunomycin (DM) is a clinically used antitumor anthracycline antibiotic, which is transported primarily by human serum albumin (HSA) in the blood. Binding characteristics are therefore of interest for both the pharmacokinetics and pharmacodynamics of DM. A new optical biosensor technique based on the resonant mirror was used to characterize interaction of DM with HSA at different temperatures and the affinity constants were obtained. The HSA-DM interaction is exothermic with having favorable enthalpy and entropy followed by the integrated van't Hoff equation analysis. Fluorescence studies showed that DM has an ability to quench the intrinsic fluorescence of HSA through a static quenching procedure according to the Stern-Volmer equation and DM displays a pH-dependent binding affinity to HSA. Molecular modeling calculations showed that the DM binds HSA to a non-classical drug binding site and further analysis of the binding site of DM within the HSA molecule suggested that hydrophobic contacts, hydrogen bond formation and electrostatic interactions account for the binding of DM.

Anti-Bacterial Agents↗

Piezoelectric biosensors for real-time monitoring of hybridization and detection of hepatitis C virus.

The piezoelectric quartz crystal resonators modified with oligonucleotide probes were used for detection of hepatitis C virus (HCV) in serum. The gold electrodes on either rough or smooth surface crystals were modified with a self-assembled monolayer of cystamine. After activation with glutaraldehyde, either avidin or streptavidin were immobilized and used for attachment of biotinylated DNA probes (four different sequences). Piezoelectric biosensors were used in a flow-through setup for direct monitoring of DNA resulting from the reverse transcriptase-linked polymerase chain reaction (RT-PCR) amplification of the original viral RNA. The samples of patients with hepatitis C were analyzed and the results were compared with the standard RT-PCR procedure (Amplicor test kit of Roche, microwell format with spectrophotometric evaluation). The piezoelectric hybridization assay was completed in 10 min and the same sensing surface was suitable for repeated use.

Base Sequence↗

A human immunodeficiency virus type 1 protease biosensor assay using bioluminescence resonance energy transfer.

A sensitive reporter assay to measure human immunodeficiency virus type 1 (HIV-1) protease (PR) activity is described in this manuscript. This assay measures PR activity as a function of the resonance energy transfer (RET) between a donor molecule [humanized sea pansy Renilla reniformis luciferase (hRLuc)] and an energy acceptor molecule, humanized green fluorescent protein (hGFP2) when expressed in mammalian cells. This is a naturally occurring phenomenon and is an emerging and powerful technology that has significant advantages over alternative in vitro PR assays. The HIV-1 Gag-p2/Gag-p7 (p2/p7) PR site was inserted between hGFP2 and hRLuc. The newly created vector, hRLuc-p2/p7-hGFP2 was co-expressed with an HIV-1 codon-optimized PR+ or PR- Gag/Pol expressor. Expression of the hRLuc-p2/p7-hGFP2 alone or with the PR- Gag-Pol expressor generated a BRET2 indicating that the PR cleavage site was not cleaved, whereas the inclusion of the PR+ Gag-Pol produced a significant reduction in the BRET2. The inclusion of PR inhibitors Saquinavir or Amprenavir, or the expression of a p2/p7 PR substrate mutant also blocked the cleavage to result in a stable BRET2 signal. Because the HIV-1 auxiliary protein Vif has been shown to modulate the HIV-1p2/p7 cleavage, this assay was then validated in studies in which Vif was expressed. When Vif was overexpressed along with hRLuc-p2/p7-hGFP2 and PR+ Gag-Pol, the decrease in BRET2 was abrogated in a dose-dependent manner, demonstrating that supraphysiologic levels of Vif block p2/p7 cleavage. An accumulation of a Gag processing intermediate was observed, indicating that p2/p7 cleavage was negatively affected. Overexpression of an RNA-binding-defective Staufen protein or a related dsRNA-binding protein TRBP had no effect on PR cleavage activity as shown by Western and BRET2 analyses. The p2/p7 processing data were confirmed by Western blot analyses. BRET is non-invasive and occurs within live cells, is measured in real time, and is not restricted to cellular compartments making it an especially attractive technology to identify small bioactive inhibitory molecules. This PR BRET2 biosensor assay can be adapted for high throughput screening of new HIV-1 PR inhibitors. It can be employed to screen for antiviral compounds that also target the proteases of other viruses.

Biosensing Techniques↗

Rapid detection of Bacillus anthracis spores directly from powders with an evanescent wave fiber-optic biosensor.

There currently are no rapid, sensitive tests to directly and reliably detect Bacillus anthracis spores in common powders. Traditional culture is time consuming and molecular techniques cannot directly process powders. This study describes a biosensor assay that detects B. anthracis at concentrations of 3.2 x 10(5) spores/mg or higher in spiked powders in less than 1 h with minimal sample preparation.

Anthrax↗

Construction and comparison of Escherichia coli whole-cell biosensors capable of detecting aromatic compounds.

The XylR regulatory protein is a transcription factor involved in the BTEX (benzene, toluene, ethylbenzene, and xylene) degradation pathway in Pseudomonas species. When XylR-dependent stimulation of transcription from a plasmid containing XylR and its cognate promoters Pr and Pu was monitored as firefly luciferase activities in Escherichia coli, a notably high level of basal activity was observed in the absence of inducers. To improve the response specificity of XylR in this system, two related but different promoters were tested for their activities; the XylS activator promoter Ps and the DmpR activator promoter Po. Po with the deletion of its own upstream activating sequences (UASs; Po') showed a very low level of basal activity compared to Pu and Ps. The maximum level with the addition of inducers was increased 3151-fold by o-xylene with Po', while it was 31.5 and 74.1 fold by m-xylene with Pu and Ps, respectively. Gel mobility shift assay showed that the purified XylR without inducers can bind to Pr/Pu but not to Pr/Po', implying that XylR multimerization with Pr/Pu could be formed for initiation of transcription in this system. The data suggest that Po' can be an excellent alternative in constructing a signal-intensified, whole-cell biosensor in response to the xenobiotics.

Bacterial Proteins↗

Direct fluorimetric determination of gamma-globulin in human serum with organic nanoparticle biosensor.

This paper describes the development of organic fluorescence nanoparticles. The nanoparticles have a narrow, tunable, symmetric emission spectrum and a broad, continuous excitation spectrum. The nanoparticles have high room-temperature fluorescence quantum yields and long fluorescence lifetime. They are also photochemically stable and water-soluble. They were used as fluorescence biosensor in the determination of proteins, which was proved to be a simple, rapid and specific method. In comparison with single organic fluorephores, these nanoparticles are brighter, more stable against photobleaching, and do not suffer from blinking. Under optimal conditions, the linear ranges of the calibration curves were 0.1-4.5 microg ml(-1) for human serum albumin (HSA), 0.2-3.5 microg ml(-1) for bovine serum albumin (BSA) and 0.04-0.8 microg ml(-1) for gamma globulin (gamma-IgG), respectively. The detection limits were 0.062 microg ml(-1) for HSA, 0.036 microg ml(-1) for BSA and 0.022 microg ml(-1) for gamma-IgG, respectively. However, when the content of HSA is lower than 0.8 microg ml(-1), HSA makes little contribution to the fluorescence quenching. So, the method was applied to direct selective quantification of gamma-IgG in human blood serum without separation of HSA. The results were in good agreement with these reported by the hospital, indicating that the method presented here is not only sensitive, selective and simple, but also reliable and suitable for practical applications.

Biosensing Techniques↗

Phosphate binding protein as the biorecognition element in a biosensor for phosphate.

This work explores the potential use of a member of the periplasmic family of binding proteins, the phosphate binding protein (PBP), as the biorecognition element in a sensing scheme for the detection of inorganic phosphate (Pi). The selectivity of this protein originates from its natural role which, in Escherichia coli, is to serve as the initial receptor for the highly specific translocation of Pi to the cytoplasm. The single polypeptide chain of PBP is folded into two similar domains connected by three short peptide linkages that serve as a hinge. The Pi binding site is located deep within the cleft between the two domains. In the presence of the ligand, the two globular domains engulf the former in a hinge-like manner. The resultant conformational change constitutes the basis of the sensor development. A mutant of PBP (MPBP), where an alanine was replaced by a cysteine residue, was prepared by site-directed mutagenesis using the polymerase chain reaction (PCR). The mutant was expressed, from plasmid pSD501, in the periplasmic space of E. coli and purified in a single chromatographic step on a perfusion anion-exchange column. Site-specific labeling was achieved by attaching the fluorophore, N-[2-(1-maleimidyl)ethyl]-7-(diethylamino)coumarin-3-carboxamide (MDCC), to the protein through the sulfhydryl group of the cysteine moiety. Steady-state fluorescence studies of the MPBP-MDCC conjugate showed a change in the intensity of the signal upon addition of Pi. Calibration curves for Pi were constructed by relating the intensity of the fluorescence signal with the amount of analyte present in the sample. The sensing system was first developed and optimized on a spectrofluorometer using ml volumes of sample. It was then adapted to be used on a microtiter plate arrangement with microliter sample volumes. The system's versatility was finally proven by developing a fiber optic fluorescence-based sensor for monitoring Pi. In all three cases the detection limits for the analyte were in the sub-microMolar range. It was also demonstrated that the sensing system was selective for phosphate over other structurally-similar anions, paving the way for the design and development of a new family of biosensors utilizing the specific binding properties of periplasmic proteins.

Amino Acid Substitution↗

Magnetoresistive-based biosensors and biochips.

Over the past five years, magnetoelectronics has emerged as a promising new platform technology for biosensor and biochip development. The techniques are based on the detection of the magnetic fringe field of a magnetically labeled biomolecule interacting with a complementary biomolecule bound to a magnetic-field sensor. Magnetoresistive-based sensors, conventionally used as read heads in hard disk drives, have been used in combination with biologically functionalized magnetic labels to demonstrate the detection of molecular recognition. Real-world bio-applications are now being investigated, enabling tailored device design, based on sensor and label characteristics. This detection platform provides a robust, inexpensive sensing technique with high sensitivity and considerable scope for quantitative signal data, enabling magnetoresistive biochips to meet specific diagnostic needs that are not met by existing technologies.

Biosensing Techniques↗

Peptide nucleic acids on microarrays and other biosensors.

The analysis of biomolecules using microarrays and other biosensors has a significant role in molecular biotechnology, and will become even more important in the future as a versatile tool for research and diagnostics. For many applications, the synthetic DNA mimic peptide nucleic acid (PNA) could be advantageous as a probe molecule, owing to its unique physicochemical and biochemical properties. PNA exhibits superior hybridization characteristics and improved chemical and enzymatic stability relative to nucleic acids. Furthermore, its different molecular structure enables new modes of detection, especially procedures that avoid the introduction of a label. In our opinion, all of these factors contribute significantly toward the establishment of faster and more reliable analytical processes and opens new fields of application.

Algorithms↗

Physicochemical perspectives on DNA microarray and biosensor technologies.

Detection and sequence-identification of nucleic acid molecules is often performed by binding, or hybridization, of specimen "target" strands to immobilized, complementary "probe" strands. A familiar example is provided by DNA microarrays used to carry out thousands of solid-phase hybridization reactions simultaneously to determine gene expression patterns or to identify genotypes. The underlying molecular process, namely sequence-specific recognition between complementary probe and target molecules, is fairly well understood in bulk solution. However, this knowledge proves insufficient to adequately understand solid-phase hybridization. For example, equilibrium binding constants for solid-phase hybridization can differ by many orders of magnitude relative to solution values. Kinetics of probe-target binding are affected. Surface interactions, electrostatics and polymer phenomena manifest themselves in ways not experienced by hybridizing strands in bulk solution. The emerging fundamental understanding provides important insights into application of DNA microarray and biosensor technologies.

Biosensing Techniques↗

Biosensors based on binding-modulated donor-acceptor distances.

The promising recognition characteristics exhibited by biomolecules have caused significant interest in biomolecule-based sensor strategies. Here we review several emerging biosensor designs that use modulated electron or energy transfer to a bio-specific ligand as the signaling mechanism. The efficiencies of both electron transfer and energy transfer are strongly dependent on donor-acceptor distance. When coupled with the large conformational changes sometimes associated with biomolecular recognition, these distance-dependent processes provide a robust means for generating optical and electronic signals.

Biosensing Techniques↗

Listening to the brain: microelectrode biosensors for neurochemicals.

Chemical signalling underlies every function of the nervous system, from those of which we are unaware, for example, control of the heart, to higher cognitive functions, such as emotions, learning and memory. Neurotransmitters and neuromodulators mediate communication between neurons and between neurons and non-neural cells such as glia and muscle. In the past, the means for studying the production and release of these signalling agents directly has been limited in its temporal and spatial resolution relative to the dynamics of chemical signalling and the structures of interest in the brain. Now microelectrode biosensors are becoming available that give unprecedented spatial and temporal resolution, enabling, for the first time, direct measurement in real time of the chemical conversations between cells in the nervous system.

Animals↗

Short order nanohole arrays in metals for highly sensitive probing of local indices of refraction as the basis for a highly multiplexed biosensor technology.

A small array of subwavelength apertures patterned in a gold film on glass was characterized for use as a biosensor. It is widely believed that such arrays allow the resonance of photons with surface plasmons in the metallic film. Surface plasmon methods (and other evanescent wave methods) are extremely well suited for the measure of real time biospecific interactions. An extremely high sensitivity of 88,000%/refractive index unit was measured on an array with theoretical active area of .09 microm2. The formation of a biological monolayer was monitored. Both sensitivity and resolution were determined through measurement. The measured resolution, for a sensor with an active area of less than 1.5 microm2, is 9.4 x 10(-8) refractive index units which leads to a calculated sensitivity of 3.45E6%/refractive index unit. These values far exceed theoretical and calculated values of other grating coupled surface plasmon resonance (SPR) detectors and prism based SPR detectors. Because the active sensing area can be quite small (.025 microm2) single molecule studies are possible as well as massive multiplexing on a single chip format.

Biosensing Techniques↗

Microcantilever biosensors.

Biosensors are sensors in which biomolecular interactions are used as sensing reactions. Biomolecular interactions, when combined with a microcantilever platform, can produce an extremely powerful biosensing design. The resonance frequency of a microcantilever shifts sensitively due to mass loading from molecular interaction as in the case of any acoustic sensors. In addition, the microcantilevers also undergo bending if the molecular adsorption is confined to a single surface of a microcantilever. This cantilever bending is due to a differential surface stress caused by the forces involved in the adsorption process and is amplified by making the cantilever surfaces chemically different. Lack of specificity, the main disadvantage of the cantilevers, can be overcome by using the extremely selective biochemical reactions such as receptor-ligand, antibody-antigen, or enzyme-substrate reactions. Here we review the microcantilever technology and discuss a number of highly sensitive biochemical sensor applications based on microcantilevers.

Adsorption↗

Single-chain polymorphism analysis in long QT syndrome using planar waveguide fluorescent biosensors.

Rapid detection of single nucleotide polymorphisms (SNPs) has potential applications in both genetic screening and pharmacogenomics. Planar waveguide fluorescent biosensor technology was employed to detect SNPs using a simple hybridization assay with the complementary strand ("capture oligo") immobilized on the waveguide. This technology allows real-time measurements of DNA hybridization kinetics. Under normal conditions, both the wild-type sequence and the SNP-containing sequence will hybridize with the capture oligo, but with different reaction kinetics and equilibrium duplex concentrations. A "design of experiments" approach was used to maximize the differences in the kinetics profiles of the two. Nearly perfect discrimination can be achieved at short times (2 min) with temperatures that destabilize or melt the heteroduplex while maintaining the stability of the homoduplex. The counter ion content of the solvent was shown to have significant effect not only on the melting point of the heteroduplex and the homoduplex but also on the hybridization rate. Changes in both the stability and the difference between the hybridization rates of the hetero- and homoduplex were observed with varying concentrations of three different cations (Na(+), K(+), Mg(2+)). With the difference in hybridization rates maximized, discrimination between the hetero- and the homoduplex can be obtained at lower, less rigorous temperatures at hybridization times of 7.5 min or longer.

Biosensing Techniques↗

GTP-induced membrane binding and ion channel activity of annexin VI: is annexin VI a GTP biosensor?

Annexin VI (AnxVI) formed ion channels in planar lipid bilayers that were induced by the addition of millimolar guanosine 5'-triphosphate (GTP) at pH 7.4 and that were not accompanied by a penetration of the protein into the membrane hydrophobic region. GTP-influenced interactions of AnxVI with Ca2+/liposomes produced small structural alterations as revealed by circular dichroism and infrared spectroscopies. Guanosine 5'-3-O-(thio)-triphosphate (GTPgammaS) binding to AnxVI, promoted by the photorelease of GTPgammaS from GTPgammaS[1-(4,5-dimethoxy-2-nitrophenyl)-ethyl] (caged-GTPgammaS), affected three to four amino acid residues of AnxVI in the presence of Ca2+/liposomes, while about eight or nine amino acid residues were altered in their absence. This suggested that the nucleotide-binding site overlapped the lipid-binding domain of AnxVI. The binding of the fluorescent GTP analog, 2'-(or 3')-O-(2,4,6-trinitrophenyl)guanosine 5'-triphosphate (TNP-GTP) to AnxVI was optimal in the presence of Ca2+/liposomes, with a dissociation constant (K(d)) of 1 microM and stoichiometry of 1. TNP-GTP promoted fluorescence resonance energy transfer from tryptophan residues to the nucleotide. Ion conductance and fluorescence measurements of the C- and N-terminal fragments of AnxVI indicated distinct GTP-binding properties, suggesting that the existence of the GTP-induced ion channel activity of AnxVI is associated with the flexibility of the two halves of the protein. Such structural flexibility could contribute to a molecular mechanism of AnxVI acting as a GTP biosensor.

Annexin A6↗

Kinetics of ligand binding to receptor immobilized in a polymer matrix, as detected with an evanescent wave biosensor. I. A computer simulation of the influence of mass transport.

The influence of mass transport on ligand binding to receptor immobilized in a polymer matrix, as detected with an evanescent wave biosensor, was investigated. A one-dimensional computer model for the mass transport of ligand between the bulk solution and the polymer gel and within the gel was employed, and the influence of the diffusion coefficient, the partition coefficient, the thickness of the matrix, and the distribution of immobilized receptor were studied for a variety of conditions. Under conditions that may apply to many published experimental studies, diffusion within the matrix was found to decrease the overall ligand transport significantly. For relatively slow reactions, small spatial gradients of free and bound ligand in the gel are found, whereas for relatively rapid reactions strong inhomogeneities of ligand within the gel occur before establishment of equilibrium. Several types of deviations from ideal pseudo-first-order binding progress curves are described that resemble those of published experimental data. Extremely transport limited reactions can in some cases be fitted with apparently ideal binding progress curves, although with apparent reaction rates that are much lower than the true reaction rates. Nevertheless, the ratio of the apparent rate constants can be semiquantitatively consistent with the true equilibrium constant. Apparently "cooperative" binding can result from high chemical on rates at high receptor saturation. Dissociation in the presence of transport limitation was found to be well described empirically by a single or a double exponential, with both apparent rate constants considerably lower than the intrinsic chemical rate constant. Transport limitations in the gel can introduce many generally unknown factors into the binding progress curve. The simulations suggest that unexpected deviations from ideal binding progress curves may be due to highly transport influenced binding kinetics. The use of a thinner polymer matrix could significantly increase the range of detectable rate constants.

Binding Sites↗

The synthesis of 16-mercaptohexadecanyl glycosides for biosensor applications.

The Pk trisaccharide and the central disaccharide element of asialo GM1 activated as their trichloroacetimidates were each used to glycosylate 16-(p-toluensulfonyloxy) hexadecanol 1. Displacement of the tosyl group by thiocyanate followed by sodium borohydride reduction and saponification afforded oligosaccharide 16-mercaptohexadecanyl glycosides that were isolated as the corresponding disulfides 6 and 17 unless oxygen was rigorously excluded from the solvents used for work-up. Dithiothreitol reduction of disulfides and subsequent isolation under an inert atmosphere with degassed solvents gave the thiols 7 and 18. Chemisorption of omega-glycosyl alkanethiols and alkanethiols onto gold electrodes produces self-assembled monolayers that can act as amperometric biosensors for the detection of proteins that bind to the immobilized oligosaccharide epitope.

Biosensing Techniques↗