PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95Linked to original sources

A novel aldehyde dextran sulfonate matrix for affinity biosensors.

Aldehyde dextran sulfonate (ADS), a modified oligosaccharide polymer, was used to prepare a new matrix structure for affinity biosensors. The principal difference between the ADS matrix and similar structures developed previously results from presence of two active functional groups in the matrix, namely, aldehyde and sulfonate. These groups perform two different functions in the matrix. The aldehyde group is responsible for covalent bonding in the biomaterials, and the negatively charged sulfonate group provides electrostatic attraction of the positively charged biomolecules. By varying the ratio between the aldehyde and sulfonate groups in the matrix, one can control contributions from the two binding modes (covalent and electrostatic). A number of oligosaccharides, such as simple dextran, aldehyde dextran (AD), aldehyde dextran sulfonate (ADS) and aldehyde ethylcellulose (AEC), were used for preparation of matrix structures. The properties of the obtained matrices were analysed and compared. Surface plasmon resonance (SPR) was used as the main technique to characterize the matrix structures.

Aldehydes↗

Development and study of an amperometric biosensor for the in vitro measurement of low concentration of putrescine in blood.

An amperometric biosensor was developed for the in vitro determination of putrescine in blood samples because elevated level of putrescine in blood can be a diagnostic indicator of certain kinds of cancer. The electrochemical transducer consisted of a flat form, three electrode amperometric micro-cell fabricated with thin film photolithography on flexible Kapton substrate. An immobilized putrescine oxidase (PUO) layer provided the biocatalytic oxidation of the putrescine, while the generated hydrogen peroxide was detected on the platinum-working electrode. An electropolymerized poly(m-phenylenediamine) (pPDA) size-exclusion layer was used to protect the working electrode from fouling and to prevent signal generation by common electroactive interferents present in blood. The preparation of the biocatalytic enzyme- and outer protective layers was optimized for improved sensitivity and response time. A detection limit of 50 nM was achieved in pH-adjusted whole blood samples, which is below pathological levels.

Biosensing Techniques↗

Feasibility of protein A for the oriented immobilization of immunoglobulin on silicon surface for a biosensor with imaging ellipsometry.

The feasibility of using protein A to immobilize antibody on silicon surface for a biosensor with imaging ellipsometry was presented in this study. The amount of human IgG bound with anti-IgG immobilized by the protein A on silicon surface was much more than that bound with anti-IgG immobilized by physical adsorption. The result indicated that the protein A could be used to immobilize antibody molecules in a highly oriented manner and maintain antibody molecular functional configuration on the silicon surface. High reproducibility of the amount of antibody immobilization and homogenous antibody adsorption layer on surfaces could be obtained by this immobilization method. Imaging ellipsometry has been proven to be a fast and reliable detection method and sensitive enough to detect small changes in a molecular monolayer level. The combination of imaging ellipsometry and surface modification with protein A has the potential to be further developed into an efficient immunoassay protein chip.

Animals↗

In vivo voltammetry and concomitant electrophysiology at a single micro-biosensor to analyse ischaemia, depression and drug dependence.

Electrochemical methods such as voltammetry can be used to understand patho-physiological mechanisms of action and, therefore, develop therapeutic approaches. In particular, voltammetry with treated micro-biosensors (carbon fibre micro-electrodes, mCFE) has been used to study models of (1) ischaemia; (2) drug dependence, and in particular craving; (3) depression. In addition, in studies (1) and (3) concomitant in vivo voltammetric and electrophysiological analysis has been performed by means of the same mCFE. Original data concerning ascorbate release in ischaemia, peptidergic activity during craving for drugs of abuse and concomitant voltammetric and electrophysiological changes of the serotonergic system in rats submitted to forced swimming test or to pharmacological treatment with the selective serotonin reuptake inhibitor fluoxetine are shown and discussed.

Animals↗

Study of substrate-enzyme interaction between immobilized pyridoxamine and recombinant porcine pyridoxal kinase using surface plasmon resonance biosensor.

Pyridoxal kinase (PK) is an important enzyme involved in bioactivation of vitamin B(6). Binding of PK with its substrate is the prerequisite step for the subsequent catalytic phosphorylation of the substrate. In the present study, a surface plasmon resonance biosensor (BIAcore) was employed to characterize the binding interaction between wild-type porcine PK and an immobilized substrate, pyridoxamine. Pyridoxamine was modified with 11-mercaptoundecanic acid and immobilized on a sensor chip through the formation of a self-assembled monolayer. The binding of PK to the immobilized pyridoxamine was followed in real time and the kinetic parameters were derived from non-linear analysis of the sensorgram. The effects of buffer pH, monovalent cations (Na(+), K(+)) and divalent cations (Mn(2+), Zn(2+), Mg(2+)) on the binding kinetics were determined. Optimal pH for PK-pyridoxamine interaction in the absence of divalent ions is at around 7.4. While K(+) increased and Na(+) decreased the binding affinity (K(A)) of PK to immobilized pyridoxamine, all divalent cations increased the K(A) of PK for pyridoxamine. Solution phase affinity measurement based on a competitive binding assay was used to determine the affinities of PK for different vitamin B(6) analogues. The order of affinity of PK for different analogues is: pyridoxal-oxime>pyridoxine>pyridoxamine>pyridoxal>pyridoxal phosphate. This is the first study to demonstrate that buffer conditions such as pH and concentration of monovalent and/or divalent ions can directly alter the binding of PK for its substrates. The quantitative kinetic and thermodynamic parameters obtained by SPR measurement provide the insight information into the catalytic activity of this enzyme.

Animals↗

Biosensor measurement of the interaction kinetics between insulin-like growth factors and their binding proteins.

The binding kinetics of human insulin-like growth factor binding protein (IGFBP) 1-6 for recombinant human insulin-like growth factor (IGF) I and II were measured and compared in the present study using surface plasmon resonance biosensor technique. Different concentrations of IGFBPs (5-100 nM) were allowed to interact with the immobilized IGF-I or IGF-II on sensor chip surface. Both des(1-3)IGF-I and insulin are known to bind weakly to the IGFBPs and therefore are used as negative controls for the binding experiments. The resultant sensorgrams were analyzed by using simple 1:1 binding model to derive both the association rate (k(a)) and dissociation rate (k(d)) constants for IGFBP-IGF interactions. The k(a) values of IGFBPs are in the range of 1x10(4) to 9x10(5) M(-1) s(-1) for IGF-I and 7x10(3) to 1.7x10(6) M(-1) s(-1) for IGF-II, respectively. The orders of k(a) for both IGF-I and IGF-II are IGFBP-3>IGFBP-5>IGFBP-6>IGFBP-4>IGFBP-2>++ +IGFBP-1. The k(d) values of IGFBPs are in the range of 1.5x10(-5) to 2x10(-4) s(-1) for IGF-I and 3.6x10(-5) to 3.7x10(-4) s(-1) for IGF-II, respectively. The order of k(d) for IGF-I is IGFBP-6>IGFBP-5>IGFBP-4>IGFBP-3>IGFBP-2>++ +IGFBP-1 and that for IGF-II is IGFBP-5>IGFBP-6>IGFBP-2>IGFBP-4>IGFBP-3>++ +IGFBP-1, respectively. The equilibrium affinity constants (K(A)) were calculated based on the ratio of k(a)/k(d) and were more precise than the published literature values based on competitive radioligand binding assays. The systematic study enables a direct comparison on the IGF-binding properties among the various IGFBPs, and the kinetic data provide additional information to delineate the physiological role of different IGFBPs in vivo.

Biosensing Techniques↗

Biosensors in immunology: the story so far.

In conclusion, biosensors are versatile tools with a range of applications. With a thorough knowledge of possible artefacts and limitations, it possible to perform assays that were heretofore not practicable in immunology.

Allergy and Immunology↗

Specific and selective biosensor for Salmonella and its detection in the environment.

The specific and selective detection of Salmonella typhymurium based on the use of a polyclonal antibody immobilized by the Langmuir-Blodgett method on the surface of a quartz crystal acoustic wave device was demonstrated in liquid samples. These biosensors were selective to S. typhymurium in the presence of large concentrations of Escherichia coli O157:H7. They were also specific to S. typhymurium since bacteria preincubated with free antibody produced no signal. Dark-field and electron microscopy showed that two different antibodies, polyvalent somatic O and flagellar H7, were immobilized on the sensor surface producing two distinct attachments of bacteria at the liquid-solid interface. The somatic O antibody exhibits a rigid, binding, while the flagellar H7 antibody forms a flexible connection allowing a large degree of freedom. When the attachment of bacteria was rigid and strong, the responses of the acoustic wave sensors correlated with changes in the mass of bacteria present at the liquid-solid interface. In contrast, when attachment was flexible, the sensor signals were inversely proportional to the additional mass of bound bacteria. This difference is probably determined by the interfacial viscoelasticity and by acoustic and electromagnetic coupling. The signals of environmentally aged sensors with either predominantly rigid or flexible positioning of bacteria were correlated with changes in mass at the liquid-solid interface. Sensors with O or H type of binding could be used for analytical purposes.

Acoustics↗

Helicobacter pylori interactions with human gastric mucin studied with a resonant mirror biosensor.

Helicobacter pylori, a human pathogen colonizing the gastrointestinal tract, is first interacting with mucus glycoproteins to penetrate the gastric mucus layer and then attach to specific epithelial cell targets. An optical biosensor technique based on the resonant mirror was used to study H. pylori interactions with human gastric mucin. The mucin preparation was immobilized on the sensor surface to set up the experimental model, close to the in vivo situation. Both sialylated and sulphated oligosaccharides interfered with the H. pylori binding to the immobilized mucin by reducing or abolishing the binding of the bacteria. Furthermore, the displacement of the bacteria from immobilized mucin by highly sulphated glycosaminoglycans was observed.

Binding, Competitive↗

Enzyme reactions in the presence of cyclodextrins: biosensors and enzyme assays.

Cyclodextrins, macrocyclic carbohydrates with apolar internal cavities, can form complexes with, and solubilize many normally water-insoluble compounds. Ferrocene and its derivatives, tetrathiafulvalene and tetramethylbenzidine, can function as redox mediators, but are insoluble in water; when they are complexed with cyclodextrins, they can be used in enzymatic assays and in the construction of mediated biosensors. In addition, the solubilization of polynuclear aromatic hydrocarbons (PAHs), including the potent carcinogen benzo[a]pyrene, by cyclodextrins has enabled the detection of these important environmental contaminants.

Animals↗

The integration of SPR biosensors with mass spectrometry: possible applications for proteome analysis.

The successful integration of biospecific interaction analysis based on surface plasmon resonance and mass spectrometry produces a powerful technique that couples the benefits of sensitive affinity capture and characterization of binding events with the ability to characterize interacting molecules. A variety of biosensors has been used to capture proteins and peptides biospecifically on sensor surfaces, with subsequent analysis using mass spectrometry. Applying this type of analysis to proteomic studies could lead to ligand and protein-complex identification, and might provide clues leading to the identification of pathways.

Amino Acid Sequence↗

Recombinant microorganisms as environmental biosensors: pollutants detection by Escherichia coli bearing fabA'::lux fusions.

A set of genetically engineered Escherichia coli strains was constructed, in which the promoter of the fabA gene is fused to Vibrio fischeri luxCDABE either in a multi-copy plasmid or as a single copy chromosomal integration. The fabA gene codes for beta-hydroxydecanoyl-ACP dehydrase, a key enzyme in the synthesis of unsaturated fatty acids, and is induced when fatty acid biosynthesis pathways are interrupted. A dose-dependent and highly sensitive bioluminescent response to a variety of chemicals was controlled by the fadR gene. A tolC mutant E. coli host displayed generally lower detection threshold for toxicants. A chromosomal integration of a single copy of the fabA'::lux fusion led to a markedly lower background luminescence, but did not yield an improvement in overall performance. It is proposed that these or similarly constructed reporters of fatty acid biosynthesis inhibition may serve as novel microbial toxicity biosensors.

Artificial Gene Fusion↗

A microelectronic conductimetric biosensor.

The fabrication and operation of a microelectronic conductimetric biosensor is described. The device monitors the change in solution conductance occasioned by the catalytic action of enzymes immobilised over a planar conductance cell comprising serpentined and interdigitated metal conductor tracks. The output of the instrument was linear over a 3 min period on addition of urea to a sample cell overlaid with immobilised urease. The responses to any given urea concentration were reproducible to within approximately +/- 1%. The device responds to urea present in serum samples.

Electrochemistry↗

Initiation of Escherichia coli ribosomes on matrix coupled mRNAs studied by optical biosensor technique.

The optical biosensor technique, based on the surface plasmon resonance (SPR) phenomenon, has been used to study the initiation of protein synthesis by E. coli ribosomes on surface coupled mRNA. mRNA was first periodate oxidized and then hydrazide coupled to the surface of a CM5 sensor chip. The formation of initiation complexes on the surface coupled mRNA was monitored in real-time with a BIACORE 2000 instrument. Mature 70S*mRNA*fMet-tRNA(Met) initiation complexes were assembled on mRNA by sequential introduction of the 30S and 50S subunits supplemented with appropriate initiation factors and fMet-tRNA(Met). We show that the formation of 70S*mRNA complexes on the surface coupled mRNA proceeds efficiently only in the presence of tRNA. Moreover, 70S*mRNA*fMet-tRNA(Met) complexes formed with fMet-tRNA(Met) are more stable than similar complexes formed with deacylated tRNAs. The efficient formation and slow dissociation of mature 70S*mRNA*fMet-tRNA(Met) initiation complexes are most easily explained by the stabilization of the interaction of the ribosomal subunits by fMet-tRNA(Met). This work demonstrates the feasibility of the BIACORE technique for studying the initiation of protein synthesis.

Base Sequence↗

Quantification of plasma-derived blood coagulation factor VIII by real-time biosensor measurements.

Plasma-derived blood coagulation factor VIII was analyzed in real time using biosensor technology. Monoclonal antibodies directed against the heavy and against the light chain of factor VIII were immobilized on different carboxymethyl dextran surfaces. Different factor VIII concentrations were injected over the antibody surfaces in parallel and response levels were determined from the dissociation phase at a fixed time after sample injection. Serial dilutions of plasma-derived factor VIII with known concentrations determined by a commercial FVIIIC:Ag ELISA were used as standards. A quantification limit of 0.9 I.U./ml with antibody 530p and 1.5 I.U./ml with antibody 531p was calculated. Intra-assay precision expressed as percent coefficient of variation was below 10% for concentrations above 0.6 I.U./ml. Inter-assay precision for antibody 530p was below 20% for concentrations higher than 0.6 I.U./ml. For 531p, inter-assay precision was below 10% for concentrations higher than 2 I.U./ml. A sensor chip lifetime in respect to regeneration of at least 100 cycles for both antibodies was found. The small sample requirement of 35 microl allows fast analysis of different FVIII products and the use of two monoclonal antibodies directed against two different FVIII domains provides additional information about the integrity of the FVIII molecule.

Biosensing Techniques↗

Detection of hepatitis B virus by piezoelectric biosensor.

A highly sensitive piezoelectric HBV DNA biosensor has been developed based on the sensitive mass-transducing function of the quartz crystal microbalance and the speciality of nucleic acid hybridization reaction. HBV nucleic acid probe was immobilized onto the gold electrodes of a 9 MHz AT-cut piezoelectric quartz crystal with the polyethyleneimine adhesion, glutaraldehyde cross-linking (PEI-Glu) method or the physical adsorption method. The coated crystal with the PEI-Glu method to immobilized HBV nucleic acid probe showed the better results than the physical adsorption method with respect to sensitivity reproducibility and stability. The frequency shifts of hybridization have better linear relationship with the amount of HBV DNA, when the amount was in range 0.02-0.14 microg/ml. The crystal could be regenerated nearly five times without perceptible decrease of sensitivity.

Biosensing Techniques↗

Electrochemical biosensor for the interaction of DNA with the alkylating agent 4,4'-dihydroxy chalcone based on guanine and adenine signals.

The interaction of an alkylating agent, 4,4'-dihydroxy chalcone (DHC) with calf thymus double stranded DNA (dsDNA) and calf thymus single stranded DNA (ssDNA) was studied electrochemically based on the oxidation signals of guanine and adenine by using differential pulse voltammetry (DPV) at carbon paste electrode (CPE). As a result of the alkylation of DHC between the base pairs in dsDNA, the voltammetric signal of guanine and adenine greatly decreased. After the interaction of DHC with ssDNA, a higher decrease in the oxidation signals of guanine and adenine was observed under the same conditions. The partition coefficients of DHC at dsDNA and ssDNA modified CPEs were calculated. The interactions of DHC with synthetic polynucleotides, such as polyguanylic acid and polyadenylic acid were also observed. In addition, the detection limit and the reproducibility were determined by using DPV. The interaction of DHC with dsDNA in solution-phase was also investigated and the results were compared with the ones obtained by surface immobilized dsDNA. The application of electrochemical DNA biosensor for monitoring the DNA-alkylating agent interactions was explored.

Adenine↗

Flow-injection amperometric determination of dopamine in pharmaceuticals using a polyphenol oxidase biosensor obtained from soursop pulp.

The amperometric determination of dopamine (Do) in pharmaceuticals formulations by flow injection analysis (FIA) is proposed. An enzymatically modified carbon paste electrode constituted by 25% (w/w) of polyphenol oxidase obtained from Annona muricata L. tissue, 30% (w/w) of graphite, 30% (w/w) of silicone and 15% (w/w) of 7,7,8,8 tetracyanoquinodimethane (TCNQ), was used as flow-through detector. The flow amperometric detection was carried out at a potential of 0.10 V (vs. Ag/AgCl) when an injected sample volume of 250 microl was inserted on a 0.3 M phosphate buffer carrier solution (pH 7.8) flowing at 2.5 ml/min. The developed biosensor showed good stability and reproducibility, enabling up to 500 determinations in 60 days, without considerable loss of enzymatic activity. The FIA system presented a linear response to Do concentrations in the interval from 2 x 10(-2) to 2 x 10(-4) M, with relative standard deviations lower than 1.5%. The kinetic parameter K(M) for the soluble and immobilized enzyme was 1.45 x 10(-2) and 1.91 x 10(-2) M, respectively. In the analyses of different commercially pharmaceutical formulations a relative deviation lower than about 3.4% was obtained.

Annona↗