An integrated NAD+-dependent enzyme-functionalized field-effect transistor (ENFET) system: development of a lactate biosensor.

An integrated NAD+-dependent enzyme field-effect transistor (ENFET) device for the biosensing of lactate is described. The aminosiloxane-functionalized gate interface is modified with pyrroloquinoline quinone (PQQ) that acts as a catalyst for the oxidation of NADH. Synthetic amino-derivative of NAD+ is covalently linked to the PQQ monolayer. An affinity complex formed between the NAD+/PQQ-assembly and the NAD+-cofactor-dependent lactate dehydrogenase (LDH) is crosslinked and yields an integrated biosensor ENFET-device for the analysis of lactate. Biocatalyzed oxidation of lactate generates NADH that is oxidized by PQQ in the presence of Ca2+-ions. The reduced catalyst, PQQH2, is oxidized by O2 in a process that constantly regenerates PQQ at the gate interface. The biocatalyzed formation of NADH and the O2-stimulated regeneration of PQQ yield a steady-state pH gradient between the gate interface and the bulk solution. The changes in the pH of the solution near the gate interface and, consequently, the gate potential are controlled by the substrate (lactate) concentration in the solution. The device reveals the detection limit of 1 x 10(-4) M for lactate and the sensitivity of 24+/-2 mV dec(-1). The response time of the device is as low as 15 s.

Biosensing Techniques↗

Simultaneous detection of six biohazardous agents using a planar waveguide array biosensor.

Recently, we demonstrated that an array biosensor could be used with cocktails of fluorescent antibodies to perform three assays simultaneously on a single substrate, and that multiple samples could be analyzed in parallel. We extend this technology to demonstrate the simultaneous analysis of six samples for six different hazardous analytes, including both bacteria and protein toxins. The level of antibody cross-reactivity is explored, revealing a possible common epitope in two of the toxins. A panel of environmental interferents was added to the samples; these interferents neither prevented the detection of the analytes nor caused false-positive responses.

Bacteria↗

Development of dual receptor biosensors: an analysis of FRET pairs.

The development of a dual receptor detection method for enhanced biosensor monitoring was investigated by analyzing potential fluorescent resonance energy transfer (FRET) pairs. The dual receptor scheme requires the integration of a chemical transducer system with two unique protein receptors that bind to a single biological agent. The two receptors are tagged with special molecular groups (donors and acceptors fluorophores) while the chemical transduction system relies on the well-known mechanisms of FRET. During the binding event, the two FRET labeled receptors dock at the binding sites on the surface of the biological agent. The resulting close proximity of the two fluorophores upon binding will initiate the energy transfer resulting in fluorescence. The paper focuses on the analysis and optimization of the chemical transduction system. A variety of FRET fluorophore pairs were tested in a spectrofluorimeter and promising FRET pairs were then tagged to the protein, avidin and its ligand, biotin. Due to their affinities, the FRET-tagged biomolecules combine in solution, resulting in a stable, fluorescent signal from the acceptor FRET dye with a simultaneous decrease in fluorescent signal from the donor FRET dye. The results indicate that the selected FRET pairs can be utilized in the development of dual receptor sensors.

Biosensing Techniques↗

Biosensors for direct determination of organophosphate pesticides.

Direct, selective, rapid and simple determination of organophosphate pesticides has been achieved by integrating organophosphorus hydrolase with electrochemical and opitical transducers. Organophosphorus hydrolase catalyzes the hydrolysis of a wide range of organophosphate compounds, releasing an acid and an alcohol that can be detected directly. This article reviews development, characterization and applications of organophosphorus hydrolase-based potentiometric, amperometric and optical biosensors.

Biosensing Techniques↗

Electrocatalytic reduction of lipoic acid and electroenzymatic reduction of NAD(P)(+) for integrated dehydrogenase biosensors.

Biosensors for the oxidized substrates of NAD(P)(+)-specific dehydrogenases demand the reductive recycling of the coenzymes. So far, suitable catalysts for the corresponding two-electron transfer are not available. In the present paper, this transport has been realized by a combined electrocatalytical and electroenzymatic process. Lipoic acid has been reduced on graphite electrodes functionalized with Fe(II)-phthalocyanine in 95% yield at-1200 mV in phosphate buffer pH 7.0. With the electrocatalytically reduced product, dihydrolipoic acid, lipoamide dehydrogenase could reduce NAD(+) in 20% yield and thioredoxin reductase NADP(+) in 18.4% yield. So far, the combined electrocatalytic/electroenzymatic system has not yet been realized, mainly because at the potential needed for the lipoic acid reduction, a parallel one-electron reduction of NAD(P)(+) was observed, implying the dimerization of the coenzyme.

Biosensing Techniques↗

A biosensor for detecting changes in cognitive processing based on nonlinear systems analysis.

A new type of biosensor, based on hippocampal slices cultured on multielectrode arrays, and using nonlinear systems analysis for the detection and classification of agents interfering with cognitive function is described. A new method for calculating first and second order kernel was applied for impulse input-spike output datasets and results are presented to show the reliability of the estimations of this parameter. We further decomposed second order kernels as a sum of nine exponentially decaying Laguerre base functions. The data indicate that the method also reliably estimates these nine parameters. Thus, the state of the system can now be described with a set of ten parameters (first order kernel plus nine coefficients of Laguerre base functions) that can be used for detection and classification purposes.

Animals↗

Portable cell-based biosensor system using integrated CMOS cell-cartridges.

The use of cell-based biosensors outside of the laboratory has been limited due to many issues including preparation of the sample, maintenance of the biological environment, and integration of the electronics for data collection and analysis. This paper describes a system that addresses several of these issues with the development of an integrated silicon-polydimethylsiloxane cell-cartridge. The cell-cartridge contains a CMOS silicon chip that incorporates a digital interface, temperature control system, microelectrode electrophysiology sensors, and analog signal buffering. Additionally, the cell-cartridge supports two separate cell populations in two 10 microl sealed chambers that have independent fluidic channels for sample injection. A portable, microcontroller-based electronics system capable of monitoring the action potential (AP) activity within the cell-cartridges was also developed. The AP activities of cardiomyocyte syncytia in the two chambers differentially responded to the flow of a control medium versus the flow of a biochemical agent. The cell-cartridges and portable electronics system were used to successfully record AP activity from cardiomyocytes outside of the laboratory under realistic application conditions.

Action Potentials↗

General purpose, field-portable cell-based biosensor platform.

There are several groups of researchers developing cell-based biosensors for chemical and biological warfare agents based on electrophysiologic monitoring of cells. In order to transition such sensors from the laboratory to the field, a general-purpose hardware and software platform is required. This paper describes the design, implementation, and field-testing of such a system, consisting of cell-transport and data acquisition instruments. The cell-transport module is a self-contained, battery-powered instrument that allows various types of cell-based modules to be maintained at a preset temperature and ambient CO(2) level while in transit or in the field. The data acquisition module provides 32 channels of action potential amplification, filtering, and real-time data streaming to a laptop computer. At present, detailed analysis of the data acquired is carried out off-line, but sufficient computing power is available in the data acquisition module to enable the most useful algorithms to eventually be run real-time in the field. Both modules have sufficient internal power to permit realistic field-testing, such as the example presented in this paper.

Action Potentials↗

Disposable TSM-biosensor based on viscosity changes of the contacting medium.

The thickness shear mode (TSM)-sensor responds to changes of mechanical properties of the material contacting the surface of the sensor. One of the material properties is the viscosity of a liquid. Abiosensor based on the TSM-resonator for the detection of endotoxin has been developed. It exploits the viscosity-density change during the reaction of endotoxin with limulus amebocyte lysate (LAL). The effect of surface properties of the sensor has been investigated to achieve better output signals. It is shown that the sensor requires a hydrophilic surface to get a better coupling between the sensor and the LAL-endotoxin solution. The TSM biosensor is able to detect an endotoxin concentration as low as 100 fg/ml by using only 50-microl standard LAL solution. The disadvantages of reusable sensors, such as the contamination from previous measurement of endotoxin and the cost of the regeneration or reclining processes of the sensor, have been eliminated by using a cost effective disposable TSM-sensor.

Animals↗

Biosensor based on enzyme-catalysed degradation of thin polymer films.

A biosensor based on the enzyme-catalysed dissolution of biodegradable polymer films has been developed. Three polymer-enzyme systems were investigated for use in the sensor: a poly(ester amide), which is degraded by the proteolytic enzyme alpha-chymotrypsin; a dextran hydrogel, which is degraded by dextranase; and poly(trimethylene) succinate, which is degraded by a lipase. Dissolution of the polymer films was monitored by Surface Plasmon Resonance (SPR). The rate of degradation was directly related to enzyme concentration for each polymer/enzyme couple. The poly(ester amide)/alpha-chymotrypsin couple proved to be the most sensitive over a concentration range from 4 x 10(-11) to 4 x 10(-7) mol l(-1) of enzyme. The rate of degradation was shown to be independent of the thickness of the poly(ester amide) films. The dextran hydrogel/dextranase couple was less sensitive than the poly(ester amide)/alpha-chymotrypsin couple but showed greater degradation rates at low enzyme concentrations. Enzyme concentrations as low as 2 x 10(-11) mol l(-1) were detected in less than 20 min. Potential fields of application of such a sensor system are the detection of enzyme concentrations and the construction of disposable enzyme based immunosensors, which employ the polymer-degrading enzyme as an enzyme label.

Biodegradation, Environmental↗

Fabrication of a sensing module using micromachined biosensors.

Micromachining is a powerful tool in constructing micro biosensors and micro systems which incorporate them. A sensing module for blood components was fabricated using the technology. The analytes include glucose, urea, uric acid, creatine, and creatinine. Transducers used to construct the corresponding sensors were a Severinghaus-type carbon dioxide electrode for the urea sensor and a Clark-type oxygen electrode for the other analytes. In these electrodes, detecting electrode patterns were formed on a glass substrate by photolithography and the micro container for the internal electrolyte solution was formed on a silicon substrate by anisotropic etching. A through-hole was formed in the sensitive area, where a silicone gas-permeable membrane was formed and an enzyme was immobilized. The sensors were characterized in terms of pH and temperature dependence and calibration curves along with detection limits. Furthermore, the sensors were incorporated in an acrylate flow cell. Simultaneous operation of these sensors was successfully conducted and distinct and stable responses were observed for respective sensors.

Biosensing Techniques↗

A receptor-based biosensor for lipoprotein docking at the endothelial surface and vascular matrix.

Proteoheparan sulfate can be adsorbed to a methylated silica surface in a monomolecular layer via its transmembrane hydrophobic protein core domain. Due to electrostatic repulsion, its anionic glycosaminoglycan side chains are stretched out into the blood substitute solution, representing a receptor site for specific lipoprotein binding through basic amino acid-rich residues within their apolipoproteins. The binding process was studied by ellipsometric techniques showing that HDL has a high binding affinity to the receptor and a protective effect on interfacial heparan sulfate proteoglycan layers, with respect to LDL and Ca(2+) complexation. LDL was found to deposit strongly at the proteoheparan sulfate, particularly in the presence of Ca(2+), thus creating the complex formation "proteoglycan-low density lipoprotein-calcium". This ternary complex build-up may be interpreted as arteriosclerotic nanoplaque formation on the molecular level responsible for the arteriosclerotic primary lesion. On the other hand, HDL bound to heparan sulfate proteoglycan protected against LDL docking and completely suppressed calcification of the proteoglycan-lipoprotein complex. In addition, HDL and aqueous garlic extract were able to reduce the ternary complex deposition and to disintegrate HS-PG/LDL/Ca(2+) aggregates. Although much remains unclear regarding the mechanism of lipoprotein depositions at proteoglycan-coated surfaces, it seems clear that the use of such systems offers possibilities for investigating lipoprotein deposition at a "nanoscopic" level under close to physiological conditions. In particular, Ca(2+)-promoted LDL deposition and the protective effect of HDL, even at high Ca(2+) and LDL concentrations, agree well with previous clinical observations regarding risk and beneficial factors for early stages of atherosclerosis. Therefore, we believe that the system can be of some use in investigations, e.g. of the interplay between different lipoproteins in arteriosclerotic plaque formation, as well as in high throughput screening of candidate drugs to atherosclerosis in a biosensor application.

Arteriosclerosis↗

Development of a quantitative relationship between inhibition percentage and both incubation time and inhibitor concentration for inhibition biosensors--theoretical and practical considerations.

Theoretical and practical insights into the design and development of immobilised enzyme inhibition biosensors are reported. A general mathematical expression relating the percent of enzyme inhibition (i.e. the analytical signal) to both the inhibitor concentration and the incubation time is presented. The relevant physical, chemical and biochemical parameters required by the model are developed and discussed in terms of the inhibition of acetylcholinesterase by the organophosphorous pesticide, paraoxon. A second enzyme, choline oxidase and an amperometric transducer are used to facilitate the determination acetylcholinesterase inhibitor.

Acetylcholinesterase↗

Epitope mapping analysis of apolipoprotein B-100 using a surface plasmon resonance-based biosensor.

Using a surface plasmon resonance (SPR)-based biosensor (BIA-technology), we have studied the interaction of ten different murine monoclonal antibodies (mAbs, all IgG(1)), raised against the main protein constituent of human low density lipoprotein (LDL), i.e. the apolipoprotein B-100 (apoB-100). These mAbs identify distinct domains on apoB-100, relevant to LDL-receptor interaction: epitopes in the amino-terminal region (mAbs L7, L9, L10 and L11: aa 1-1297) and in the middle region (mAb 6B: aa 1480-1693; mAbs 2A, 3B: aa 2152-2377; mAbs 9A, L2 and L4: aa 2657-3248) of native apoB-100. A multisite binding analysis was performed to further characterize the epitopes recognized by all these mAbs. A rabbit anti-mouse IgG(1)-Fc antibody (RAM.Fc) was first coupled to the gold surface in order to capture one anti-human apoB-100 mAb. ApoB-100 protein was subsequently injected and allowed to react with this immobilized, oriented antibody. Multisite binding assays were then performed, by sequentially flowing other mAbs, in different orders, over the sensing surface. The capacity of each mAb to interact with the entrapped apoB-100 in a multimolecular complex was monitored in real time by SPR. The results achieved were comparable to those obtained by western immunoblotting using the same reagents. However, SPR ensures a more detailed epitope identification, demonstrating that BIA-technology can be successfully used for mapping distinct epitopes on apoB-100 protein in solution dispensing with labels and secondary tracers; moreover, compared with conventional immunoassays, it is significantly time saving (CNR-P.F. MADESS 2).

Animals↗

Quartz tuning fork biosensor.

The use of quartz tuning forks for biosensor applications is investigated. The basis of the sensor is to coat the tuning fork surfaces with specific biomolecules and measure subsequent mass loading from the selective binding of complementary analytes. Two experimental set-ups are evaluated, direct mechanical excitation and self-excitation. Mechanical excitation is achieved by mounting the fork on a piezoelectric plate and it is found that the change in oscillation amplitude on adsorption can be monitored to give the change in mass. However, a major drawback is that the sensitivity is determined by the Q-factor, which varies significantly between different sensors and different experimental arrangements. In self-excitation mode, tuning fork motion is activated and detected by placing the fork within a tuned circuit. Using self-excitation mode, anti-human IgG modified tuning forks can sense the binding of human IgG in the range of 5-100 microg ml(-1). The significance of this study is that quartz tuning forks are routinely made using standard microfabrication process, thus suggesting the possibility of facile microfabrication of arrays of quartz sensors.

Audiometry↗

A novel ISFET-type biosensor based on P450 monooxygenases.

We made a biosensor based on ion-sensitive field effect transistor (ISFET) using P450 monooxygenase. ISFETs are electrical devices and have been used as pH sensors. We used genetically engineered P450 monooxygenase for our research because of its high enzymatic activity. The fusion enzyme between rat CYP1A1P450 monooxygenase and yeast NADPH-cytochrome P450 oxidoreductase was expressed in yeast Saccharomyces cerevisiae strain AH22. Yeast microsomal membranes were immobilized in an agarose layer on the ISFET. o-Deethylation of 7-ethoxycoumarin to 7-hydroxycoumarin was catalyzed by the enzyme in the presence of nicotinamide adenine dinucleotide phosphate reduced form (NADPH). Formation of 7-hydroxycoumarin from 7-ethoxycoumarin was also measured by fluorescence. The difference of the voltage between the ISFET device and control device without enzymes showed a voltage increase along with the enzymatic reaction of P450 monooxygenases, and this voltage increase in the device was inhibited by addition of MnCl(2), an inhibitor of P450 monooxygenase. There was a positive correlation between the voltage increase in the ISFET device and the fluorescence intensity. This is the first electrochemical biosensing using P450 monooxygenases immobilized on the ISFET, and is applicable to the sensing of chlorophenol compounds.

Biosensing Techniques↗

A portable fiber-optic pesticide biosensor based on immobilized cholinesterase and sol-gel entrapped bromcresol purple for in-field use.

A fiber-optic biosensor for the detection and determination of the pesticides carbaryl and dichlorvos was developed. The sensing bioactive material was a three-layer sandwich. The enzyme cholinesterase was immobilized on the outer layer, consisting of hydrophilic modified polyvinylidenefluoride membrane. The membrane was in contact with an intermediate sol-gel layer that incorporated bromcresol purple, deposited on an inner glass disk. The sensor operated in a static mode at room temperature and the rate of the inhibited reaction served as an analytical signal. Calibration curves were obtained for carbaryl and dichlorvos, with useful concentration ranges 0.11-8.0 mg l(-1) for carbaryl and 5.0-30 microg l(-1) for dichlorvos. The respective detection limits were 108 microg l(-1) and 5.2 microg l(-1). The method reproducibility was in the order of +/-3-5%. The method was successfully applied to the detection and determination of these pesticides in real water samples, without sample preparation steps. Recovery experiments were made and the accuracy of the method was 94.9%. No enzyme regeneration steps were applied and the sensor lifetime was 3 weeks (30% activity reduction). The bioactive mini sandwich can easily be replaced by simply unscrewing the terminal holding ring of the probe and placing a new sandwich, before the sensor is ready for use.

Biosensing Techniques↗

Engineering receptors and antibodies for biosensors.

Biosensor sensitivity and selectivity depend essentially on the properties of the biorecognition elements to be used for analyte binding. Two principally different applications are considered, (1) effects monitoring with biological components as targets for bioeffective substances, among them endocrine disruptors; and (2) immunochemical analysis employing antibodies as binding proteins for a wide variety of analytes such as pesticides. Genetic engineering provides an elegant way not only for providing unlimited amounts of biorecognition molecules but also for the alteration of existing properties and the supplementation with additional functions. Instrumental applications were carried out with the optical sensor BIAcore. The first example deals with the characterization of receptors. For this purpose, the human estrogen receptor alpha was used. Binding studies were carried out with natural as well as xenoestrogens. An equilibrium dissociation constant K(d) of 2.3x10(-10) (M) was derived for 17beta-estradiol. A competition assay was performed with a bovine serum albumin (BSA)-17beta-estradiol conjugate, immobilized at the optical sensor surface, and the free estrogen. The signals obtained represent estradiol equivalents. This format was transferred to a microplate-based enzyme-linked receptor assay. It reached a detection limit of 0.02 microg l(-1) 17beta-estradiol and proved suitable for the detection of natural and synthetic estrogens as well as xenoestrogens in field studies. The second example is targeted at kinetic and affinity measurements of recombinant antibody fragments derived from antibody libraries with s-triazine selectivities. Different strategies for the synthesis of antibody fragment libraries, followed by the selection of specific antibody variants, were examined. An antibody library was derived from a set of B cells. Chain shuffling of the heavy and light chains provided the best binders. An enzyme linked immunosorbent assay (ELISA) was achieved for atrazine with an IC(50) of 0.9 microg l(-1) and a detection limit of 0.2 microg l(-1). The close relations between the optimization of recombinant antibodies by evolutionary strategies and genetic algorithms are considered.

Algorithms↗