Extension of the low pressure range of the ionization gauge.
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The ETS-domain transcription factor family can be divided into a series of subfamilies. Elk-1 represents the founding member of the ternary complex factor (TCF) subfamily. By focusing on the TCF subfamily, we can demonstrate the complexities that exist in the function and regulation of ETS-domain transcription factors. This article focuses on Elk-1 in detail and summarizes the functions of other TCFs. The key themes covered include the domain structure of the TCFs, the mechanisms of complex formation with serum response factor, regulation of TCFs by mitogen-activated protein kinase cascades, and transcriptional regulatory properties of the TCFs. Finally, the emerging role of the TCFs in vivo is discussed. A picture is developing indicating that, while these proteins exhibit significant sequence and functional conservation, key differences in their structure and regulation are being identified which may relate to unique functions of these proteins in vivo.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A first step in the dosimetry of fast-ion beams is the determination of accurate Bragg (ionization) functions. Bragg functions for several substances have been measured and calculated for 3480 MeV carbon ions. In the measurements, the ions first traverse an absorber in which the energy is reduced to either 1900 or 1200 MeV, then a "range gauge" followed by a thin ionization chamber. Functions are calculated with an analytical method using convolutions of straggling functions. This approach gives results without the stochastic variations implicit in Monte Carlo methods. The comparison of measured and calculated functions shows how reliable the calculations are. An important part of the calculations is the determination of the total range of the ions. The range can be determined from the Bragg function. The measured range is given by the sum of the thickness of the absorber and the residual range measured with the range gauge. For water, the range is about 150 mm, and the precision of the measurements is +/-0.05 mm. Because the ion energy at the surface of the absorber fluctuates with time, measurements with water are used to define this energy. Thus the ranges (or average stopping powers) in absorbers are obtained relative to those in water. Measured ranges R(m) are compared with ranges R(0) calculated with a current version of the Bethe theory. For light absorbers (atomic number Z < 20), differences between R(m) and R(0) are less than +/-0.3 mm; for Z > 20 differences are between 0 and +/-0.6 mm. This agreement between calculated and measured ranges confirms the value I = 80 eV for water measured earlier for protons. The ionization by nuclear fragments is obtained from the difference between measured and calculated ionization functions, and has little influence on the ranges of the primary ions.
The full-dimensional time-dependent Schrödinger equation for the electronic dynamics of single-electron systems in intense external fields is solved directly using a discrete method. Our approach combines the finite-difference and Lagrange mesh methods. The method is applied to calculate the quasienergies and ionization probabilities of atomic and molecular systems in intense static and dynamic electric fields. The gauge invariance and accuracy of the method is established. Applications to multiphoton ionization of positronium, the hydrogen atom and the hydrogen molecular ion are presented. At very high laser intensity, above the saturation threshold, we extend the method using a scaling technique to estimate the quasienergies of metastable states of the hydrogen molecular ion. The results are in good agreement with recent experiments.
Explore the source record for details and available documents.
The glucose concentration in growth medium has been shown to regulate the number of sodium-coupled glucose transporters in LLC-PK1 epithelial cells. Epithelia grown in high concentrations of glucose express fewer transporters than epithelia grown in low concentrations of glucose. In the present work, the effect of a dose of ionizing radiation sufficient to block the incorporation of thymidine was examined in order to gauge the importance of cell replication in the hexose transport regulatory process. The low rate of thymidine incorporation in the plateau phase was completely eliminated by ionizing radiation. Under conditions of irradiation that completely blocked thymidine incorporation, down-regulation, namely the loss of alpha-methylglucoside-concentrating capacity, brought about by switching the epithelium from low to high glucose-containing medium, is independent of the irradiation and therefore most likely is also independent of cell replication. In contrast, the up-regulatory phenomenon is strongly impaired by radiation. This impairment may be due to specific radiation impairment of gene expression necessary for the up-regulatory process. It is apparent from the dose-response data that up-regulation is not inhibited by irradiation in a simple manner and is not inhibited at the same radiation dose as cell replication.
Fast cooling of muon beams will be needed for building either TeV muon colliders that might explore the electroweak gauge symmetry breaking or muon storage rings that could become ultrabright neutrino sources. Stochastic and electron cooling take longer than the muon lifetime, so attention has been focused on the potentially faster but less explored ionization cooling. Addressing recent concerns that excitation of Langmuir waves might be deleterious for ionization cooling techniques, we show that, while the hydrodynamic instability indeed might be dangerous, the waves are, in fact, stabilized through a combination of resistive and kinetic effects at a very modest emittance of the beam.
The small intestinal motor effects of fractionated doses of ionizing radiation were studied in 6 conscious dogs. Eight strain-gauge transducers were implanted on the small intestine and a single gauge on the ascending colon, of each dog. After control recordings, an abdominal dose of 250 cGy was administered three times a week on alternate days for 3 successive weeks (total dose, 2250 cGy). Recordings were then made for 4 wk of follow-up. Giant migrating contractions occurred 11 times in 520 h of control recordings in the fasted and fed state, with a mean distance of origin of 55 +/- 16 cm from the ileocolonic junction. Abdominal field irradiation significantly increased the incidence and distance of origin of these giant contractions to 438 in 745 recording hours and 158 +/- 7 cm from the ileocolonic junction, respectively. The incidence of giant migrating contractions peaked after the second dose of radiation. The amplitude ratio of radiation-induced giant migrating contractions to phase III contractions, and their duration and velocity of migration, were similar to the control state. The dogs developed diarrhea and vomiting as early as the first fraction of radiation. Irradiation also increased the incidence of retrograde giant contractions from 8 in 520 h of control recording to 42 in 745 h of recording during the radiation schedule. The radiation-induced retrograde giant contractions peaked in incidence on the day of the first fraction of radiation and were more likely to be associated with a vomiting episode than those occurring in the control period. Migrating motor complex cycling persisted during radiation and its cycle length was not different from the control or postradiation values. Our findings suggest that some of the side effects of radiation such as diarrhea, abdominal cramping, and vomiting may be related to the dramatically increased incidence of giant migrating contractions and retrograde giant contractions.
An array of techniques can be used to study cell calcium metabolism that comprises several calcium compartments and many types of transport systems such as ion channels, ATP-dependent pumps, and antiporters. The measurement of total cell calcium brings little information of value since 60 to 80% of total cell calcium is actually bound to the extracellular glycocalyx. Cell fractionation and differential centrifugation have been used to study intracellular Ca2+ compartmentalization, but the methods suffer from the possibility of Ca2+ loss or redistribution among cell fractions. Steady-state kinetic analyses of 45Ca uptake or desaturation curves have been used to study the distribution of Ca2+ among various kinetic pools in living cells and their rate of Ca2+ exchange, but the analyses are constrained by many limitations. Nonsteady-state tracer studies can provide information about rapid changes in calcium influx or efflux in and out of the cell. Zero-time kinetics of 45Ca uptake can detect instantaneous changes in calcium influx, while 45Ca fractional efflux ratio, can detect rapid stimulations or inhibitions of calcium efflux out of cells. Permeabilized cells have been successfully used to gauge the relative role of intracellular organelles in controlling [Ca2+]i. The measurement of the cytosolic ionized calcium ([Ca2+]i) is undoubtedly the most important and, physiologically, the most relevant method available. The choice of the appropriate calcium indicator, fluorescent, bioluminescent, metallochromic, or Ca2(+)-sensitive microelectrodes depends on the cell type and the magnitude and time constant of the event under study. Each probe has specific assets and drawbacks. The study of plasma membrane vesicles derived from baso-lateral or apical plasmalemma can also bring important information on the (Ca2(+)-Mg2+) ATPase-dependent calcium pump and on the kinetics and stoichiometry of the Na(+)-Ca2+ antiporter. The best strategy to study cell calcium metabolism is to use several different methods that focus on a specific problem from widely different angles.
The colonic motor effects of fractionated irradiation were studied in five conscious dogs. Seven colonic and two ileal strain gauge transducers were implanted. After control recordings, an abdominal dose of 250 cGy was administered three times a week on alternate days for three successive weeks (total dose 2,250 cGy). Recordings were then continued for 3 wk after the completion of radiation. Colonic giant migrating contractions (GMCs) occurred at a frequency of 0.15 +/- 0.05 contractions/h in the control state. Only one of these contractions (8.3%) originated in the small bowel and propagated into the colon. Abdominal field irradiation significantly increased the incidence of colonic GMCs to 0.51 +/- 0.11 contractions/h (P < 0.05). Fifty-four percent of GMCs originated in the small intestine. GMCs during the radiation schedule were associated with explosive diarrhea on seven occasions. Irradiation did not alter the frequency of colonic migrating motor complexes, but the mean duration of contractile states decreased in the middle and distal colon. Diarrhea occurred as early as the second dose of radiation. Pathological changes in the colon were correlated with motor activity. Both small intestinal and colonic GMCs reverted to control frequencies after cessation of radiation exposure. Abdominal irradiation significantly altered the contractile activity of the colon. These changes are associated with abdominal cramping and diarrhea.
Under the Atoms for Peace program, Turkey received a one MWt swimming pool reactor in 1962 that initiated a health physics program for the reactor and a Radiation Control Program (RCP) for the country's use of ionizing radiation. Today, over 13,000 radiation workers, concentrated in the medical field, provide improved medical care with 6,200 x-ray units, including 494 CAT scanners, 222 radioimmunoassay (RIA) labs and 42 radiotherapy centers. Industry has a large stake in the safe use of ionizing radiation with over 1,200 x-ray and gamma radiography and fluoroscopic units, 2,500 gauges in automated process control and five irradiators. A 48-person RCP staff oversees this expanded radiation use. One incident involving a spent 3.3 TBq (88 Ci) 60Co source resulted in 10 overexposures but no fatalities. Taiwan received a 1.6 MWt swimming pool reactor in 1961 and rapidly applied nuclear technology to the medical and industrial fields. Today, there are approximately 24,000 licensed radiation workers in nuclear power field, industry, medicine and academia. Four BWRs and two PWRs supply about 25% of the island's electrical power needs. One traumatic event galvanized the RCP when an undetermined amount of 60Co was accidentally incorporated into reinforcing bars, which in turn were incorporated into residential and commercial buildings. Public exposures were estimated to range up to 15 mSv (1.3 rem) per annum. There were no reported ill effects, except possibly psychological, to date. The RCP now has instituted stringent control measures to ensure radiation-free dwellings and work places. Albania's RCP is described as it evolved since 1972. Regulations were promulgated which followed the IAEA Basic Safety Standards of that era. With 525 licenses and 600 radiation workers, the problem was not in the regulations per se but in their enforcement. The IAEA helped to upgrade the RCP as the economy evolved from one that was centrally planned economy to a free market economy. As this transition takes place, public radiation exposures in the medical field will continue to be high until the old x-ray equipment is phased out. A small conscientious health physics staff works with limited resources to keep radiation exposures at acceptable levels. These three country RCPs, as they have evolved, have some commonality. Today, all radiation installations are licensed, both for radioactive material and x-ray equipment. Radiation workers are individually licensed or registered. All RCPs have, or are striving to have, their radiation regulations conform to ICRP 60 recommendations as spelled out in the Basic Safety Standard (1996). Finally, all three countries have as yet to find a permanent solution for their radioactive waste.
Explore the source record for details and available documents.
We investigated the effects of total abdominal fractionated irradiation on postprandial small intestinal motor activity in five dogs. Five strain-gauge transducers were attached to the seromuscular layer of the duodenum, jejunum, and ileum of each dog to record circular muscle contractions. Radiation (250 cGy) was administered three times a week on alternate days for three successive weeks (total dose, 2250 cGy). Postprandial 4-hr recordings were made once each week during radiation and at one and three weeks following completion of radiation. Duodenal mean amplitude and area under contractions did not change during or following the radiation schedule, but the mean frequency and duration of duodenal contractions decreased during the radiation schedule. Both parameters returned to baseline values postirradiation. Jejunal mean duration, amplitude, area, and frequency of contractions decreased during radiation; mean amplitude and area returned to baseline values postirradiation but not the duration and frequency of contractions. All parameters of ileal contractions decreased during radiation, and all but area and amplitudes remained depressed postirradiation. Significantly decreased strength and frequency of contractions, particularly in the jejunum and ileum occur during and following irradiation. These changes may potentially alter transit time.