PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Reticulocyte Count”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Comparison of glass K3EDTA versus plastic K2EDTA blood-drawing tubes for complete blood counts, reticulocyte counts, and white blood cell differentials.

Blood-drawing tubes made from plastic containing K2EDTA as an anticoagulant are gaining widespread use in clinical hematology. We compared complete blood count parameters, reticulocyte counts, white blood cell differentials, and flagging rates obtained with Becton Dickinson Vacutainer K3EDTA glass tubes and Vacutainer K2EDTA Plus plastic tubes and found only slight discrepancies in the results obtained with the two tube types. Although some parameter values obtained with K3EDTA glass tubes were significantly lower than those obtained with K2EDTA plastic tubes, many of these differences could be explained by the known effects of the liquid K3EDTA anticoagulant. Flagging rates on an automated cell counter were identical for the two tube types. We conclude that the differences between results obtained with K3EDTA glass tubes versus K2EDTA plastic tubes are minimal and unlikely to be of any clinical significance.

Anticoagulants↗

Inaccuracy and imprecision of reticulocyte counting.

Reticulocyte count is an essential clinical test to detect erythropoietic activity. The test has been done manually with the use of one of three dyes: new methylene blue, brilliant cresyl blue, and azure B. When reticulocyte counts with the different dyes were compared, correlation was good. When reticulocyte counts obtained by use of the dyes were compared with the count obtained by an automated counter, correlation was high. In a sampling study, the specimen prepared by a spinner method gave smaller variations than a wedge method. Intertechnologist bias was higher than inter-specimen or intra-specimen bias: The variation of the reticulocyte count was examined with from 200 to 2,000 cells; with 1,000 cells or more, variation was low. From these results, we concluded that more than 1,000 erythrocytes on one slide prepared by the spinner method should be analyzed. Clear standards for cell identification are also needed.

Blood Cell Count↗

The complete blood count and reticulocyte count--are they necessary in the evaluation of acute vasoocclusive sickle-cell crisis?

OBJECTIVE: To assess the usefulness of the complete blood count (CBC) and the reticulocyte count in the evaluation of adult patients with acute vasoocclusive sickle-cell crisis (SCC) presenting to the ED. METHODS: A 2-part study was performed. Part 1 was retrospective chart review of patients with a sole ED diagnosis of acute SCC. Part 2 was a prospective evaluation of consecutive patients presenting in SCC. In both parts of the study, patients with coexisting acute disease were excluded. The remaining patients were divided into 2 groups: admitted and released. The mean values for white blood cell (WBC) count, hemoglobin (Hb) level, and reticulocyte count were compared. In Part 2, the change (delta) from the patient's baseline in WBC count, Hb level, and reticulocyte count also was determined. Data were analyzed by 2-tailed Student's t-test. RESULTS: Part 1: There was no difference between the admitted (n = 33) and the released (n = 86) groups in mean WBC count (p = 0.10), Hb level (p = 0.25), or reticulocyte count (p = 0.08). Part 2: There was no difference between the admitted (n = 44) and the released (n = 160) groups in mean Hb level (p = 0.88), reticulocyte count (p = 0.47), delta Hb level (p = 0.88), and delta reticulocyte count (p = 0.76). There was a difference in mean WBC counts (15.8 +/- 4.9 x 10(9)/L admitted vs 12.8 +/- 4.9 x 10(9)/L released, p = 0.003) and delta WBC counts (5.1 +/- 4.6 x 10(9)/L admitted vs 1.8 +/- 4.6 x 10(9)/L released, p < 0.002). CONCLUSION: Determination of the Hb level and the reticulocyte count do not appear useful in the evaluation of acute SCC in the ED. Admission decisions appear associated with elevations in the WBC count. Further study is required to determine the true value of the WBC count in such decisions.

Adult↗

Reticulocyte count, mean reticulocyte volume, immature reticulocyte fraction, and mean sphered cell volume in elite athletes: reference values and comparison with the general population.

BACKGROUND: The role of measurement of reticulocytes and their parameters is growing in sports medicine. The use of reticulocyte counts in protocols for evaluating and screening for the suspected abuse of hormones that stimulate the bone marrow is an example. Reticulocytes are also important for evaluation of the performance and general health status of athletes, especially for monitoring therapies and diets. The current availability of fully automated haematological systems that can measure reticulocyte numbers and characteristics (volume, density) increases the potential use of these parameters in laboratory and sports medicine. Few studies have considered the application of these parameters in athletes and a lack of specific reference ranges means that their valid clinical use is difficult. METHODS: Using a Coulter LH700 instrument, we measured reticulocyte count (Retics), mean reticulocyte volume (MRV), immature reticulocyte fraction (IRF), and mean sphered cell volume (MSCV) in 106 male professional elite athletes (football and rugby players and skiers). Reference intervals for the athletes were compared with the intervals found for a control group of 73 age-matched males. RESULTS: We calculated the following reference intervals: 0.30-1.54% for Retics, 93.1-114.8 fL for MRV, 0.18-0.39% for IRF, and 76.8-94.5 fL for MSCV. CONCLUSIONS: No statistically significant differences were observed for Retics, MRV, IRF, and MSCV between elite athletes and controls. Significant differences were observed for haemoglobin (Hb), erythrocytes, haematocrit (Ht), and mean corpuscular volume. Moreover, no statistical differences were observed among different sports, whereas differences were remarked in football and rugby players between the samples drawn before the start of competitive season and the samples drawn during the season, demonstrating that reticulocyte counts and parameters are useful for monitoring sportsmen.

Adult↗

[Comparison of various reticulocyte counting methods and the standardization of reticulocyte counting].

The reticulocyte count has been conventionally determined using a visual method. Recently, due to technological advances an automated method has come into general use in laboratories. The precision in terms of reproducibility of automated reticulocyte counters has also made rapid progress compared with the visual method. The measurements of reticulocyte counts showed good correlation among the five automated reticulocyte counters and the visual method although the accuracy of an automated method is problematical since it is not sufficient to find the true value. It remains difficult to standardize reticulocyte counting because automated reticulocyte counting is performed in accordance with the procedure specified by the respective manufactures; thus, an external quality control survey was performed for an accuracy assurance of reticulocyte counts with the participation of many laboratories. In the future, it is necessary to develop biological reference materials equal to the true value or to establish other standardization using new technology.

Humans↗

Counting reticulocytes by flow cytometry: use of thiazole orange.

Thiazole orange is a new fluorescent dye which will bind to the residual RNA in the cytoplasm of reticulocytes and allow their enumeration by FACS analysis. We have evaluated the use of this dye in the routine haematology laboratory. There is an excellent correlation between manual and FACS reticulocyte counts (r = 0.98) but FACS counting showed significantly higher precision (CV = 3.1) than the manual method (CV = 11.9) for single observer, 20.8% for multiple observers). Clinical specimens showed stable reticulocyte counts for 6 h if stored at 4 degrees C allowing efficient batching of samples. There was a significant fall in reticulocyte counts stored for 24 h at both 4 degrees C and 21 degrees C. Evaluation of 78 male and 76 female blood donors by FACS analysis gave normal ranges (mean % +/- 2 SD) of 0.74 +/- 0.48 and 0.84 +/- 0.56 respectively (P less than 0.005). When corrected to absolute values there was no sex difference (36 +/- 24 x 10(9)/l). Thiazole orange is an effective stain for the automated counting of reticulocytes by FACS analysis.

Benzothiazoles↗

Multivariate statistical modeling: alternative approach to test evaluation, applied to counting reticulocytes by flow cytometry.

We present a statistical path analysis model for the evaluation of two tests in the absence of a "gold standard" method. This model is applied to the evaluation of flow-cytometric and visual reticulocyte counting by using as the comparison method a combination of three hematological measurements: hemoglobin concentration (HGB), mean cellular volume (MCV), and erythrocyte density width (EDW). We assumed that, in general, a higher reticulocyte count is associated with a lower HGB value and with greater values for MCV and EDW. Applying this assumption and the statistical model, we demonstrated that flow cytometry was superior to visual reticulocyte counting in the low-value range studied. The path analysis model is potentially applicable in other cases where two tests are to be compared, and when no gold standard is available.

Erythrocyte Count↗

Automated reticulocyte counting: evaluation of the Coulter STKS Haematology Analyser reticulocyte counting function.

This study evaluated reticulocyte counting with the automated reticulocyte function of the Coulter STKS Haematology Analyser. This is an upgrade option for Coulter STKS and MAXIM haematology analysers. Reticulocyte counts obtained with the automated reticulocyte counting function were compared with those obtained by visual counting. Reticulocyte counting with both methods gave excellent comparability with a correlation coefficient of 0.98. Results were consistent with the well documented imprecision of the manual method with a coefficient of variation (CV) of 16-22%. In contrast, the automated reticulocyte counting function was more precise with a CV of 12.3%. In both cases, counts were stable after storage for 24 h at room temperature and 4 degrees C. Our results suggest that the use of this upgrade will be beneficial for many laboratories.

Autoanalysis↗

The effect of controlled daily blood loss on the haemoglobin concentration, erythrocyte count and reticulocyte count of male rats.

0.2, 0.6 or 1 ml of blood was removed from rats once daily on 17 consecutive days. Haemoglobin concentration and erythrocyte counts fell rapidly until day 7 or 9 and were reflected after day 2 by an increase in reticulocytes. From 9 to 17 there was little further change and 14 days after the last bleed the haematological results were within the normal range. The increase in haemoglobin production correlated well with the increase in reticulocyte numbers.

Animals↗

Automated reticulocyte counting and immature reticulocyte fraction measurement. Comparison of ABX PENTRA 120 Retic, Sysmex R-2000, flow cytometry, and manual counts.

We evaluated reticulocyte counting and measurement of immature reticulocyte fraction (IRF) with the ABX PENTRA 120 Retic blood analyzer on 300 blood samples. Reticulocyte counts were compared with those obtained by visual counting of 2,000 RBCs, by the TOA (Kobe, Japan) Sysmex R-2000 and a flow cytometry method. The parameters analyzed were the percentages of reticulocytes on all analyzers and the IRF with different modalities. The Retic Count kit (Becton Dickinson, San Jose, CA) was used with the Coulter (Hialech, FL) XL, and a mean channel of fluorescence (MCF) was calculated to fit the reticulocyte maturation. Reticulocyte counting with the ABX (Montpellier, France) PENTRA 120 Retic showed excellent precision and linearity with no significant carryover. Reticulocyte counts were stable after blood storage for 72 hours at 4 degrees C but not at room temperature (RT). IRF parameters values were stable for only 8 hours at 4 degrees C and 6 hours at RT. Comparisons of the methods showed good intraclass correlation (RI) for reticulocyte percentages between ABX PENTRA 120 Retic and Sysmex R-2000, ABX PENTRA 120 Retic and flow cytometry, Sysmex R-2000 and flow cytometry, and ABX PENTRA 120 Retic and manual counting. IRF values were correlated between fluorescence rates and RNA content, but in each case, low RI values were found, showing that Sysmex and ABX IRF values were not concordant. We obtained a significant correlation between mean fluorescence index and the MCF measured by flow cytometry, but the 2 methods were not concordant using the RI. The ABX PENTRA 120 Retic is a good instrument for analyzing reticulocyte count and percentage and allows a good analysis of IRF with several modalities.

Acute Disease↗

Automated reticulocyte counting and measurement of reticulocyte cellular indices. Evaluation of the Miles H*3 blood analyzer.

This study evaluated reticulocyte counting and measurement of reticulocyte cellular indices with the Miles H*3 blood analyzer, a new instrument that combines the Technicon/Miles technology for blood cells counting with a staining technique allowing counting of reticulocytes, quantification of staining intensity and measurement of reticulocyte cellular indices. Reticulocyte counts obtained with the Miles H*3 analyzer were compared with those obtained by manual counting, flow cytometry (thiazole orange method) and by the Sysmex R-3000 (Baxter Diagnostics) reticulocyte analyzer. Reticulocyte counting with the Miles H*3 showed excellent precision, and linearity in the range tested (1.1-49% and 1-72% reticulocytes, respectively, with two different protocols) with no significant carryover. Reticulocyte counts were stable after storing blood samples for 72 hours at 4 degrees C. Comparison of the four different methods, showed an acceptable intraclass correlation between Miles H*3 and Sysmex R-3000 (intraclass correlation coefficient, [ri] = .952), Miles H*3 and flow cytometry (ri = .922), and Sysmex R-3000 and flow cytometry (ri = .938). There was no satisfactory correlation between any of the three automated methods and the values obtained with manual counting of reticulocytes (ri = .538-.755), consistent with the well known imprecision of the manual technique. For a group of normal pediatric subjects, age 1-10, we obtained the following values (+/- SD) of reticulocyte indices: mean corpuscular volume 97.6 +/- 4.7 fL; cell hemoglobin concentration mean 28.2 +/- 1.4 g/dL; cell hemoglobin content 26.7 +/- 1.6 pg. We determined the direct cost, including depreciation, of the manual and instrumental methods. Cost/test varied from $1.61 for manual method to $6.03 for the Sysmex R-3000. Cost/test for flow cytometry and Miles H*3 were $3.34 and $3.49, respectively.

Child↗

[Reticulocyte counts in the aged].

Reticulocytes were measured on an automated reticulocyte counter in five groups; healthy adults, non-elderly patient with low hematopoiesis, adults with anemia, healthy elderly persons and elderly patients with anemia. The reticulocyte percent, absolute reticulocyte count, and reticulocyte composition as classified by fluorescence intensity (highly, moderately, and slightly fluorescent cells) were calculated. The healthy adults had a reticulocyte count of 0.70 +/- 0.55%, an absolute reticulocyte count of 4.36 +/- 1.90 X 10(4)/microliters, 2.33 +/- 1.95% highly fluorescent cells, 18.73 +/- 5.07% of moderately fluorescent cells, and 78.82 +/- 6.55% of slightly fluorescent cells. Patients with low hematopoiesis had lower counts except for the percentage of slightly fluorescent cell. Aged persons without anemia showed no differences in reticulocytes from healthy adults. However, elderly patients with anemia had a low reticulocyte count; there was no tendency towards an increase in the percentage of highly fluorescent cells or a decrease in the percentage of slightly fluorescent cells. Their reticulocyte percent was not significantly higher than healthy controls, suggesting that anemia observed in the aged arises from low hematopoietic activity in the bone marrow.

Adult↗

An automated reticulocyte counting method: preliminary observations.

We evaluated the counting of reticulocytes in the peripheral blood with a newly developed flow cytometer type of automated counter that performs a single test within 60 s. The volume of sample needed is 100 microliters and the cells are stained with auramine-O in the counter. The mean within-run reproducibility was 4.66% (CV, n = 50), and dilution of blood gave highly linear results with an r value of 0.996. Correlation was good between manual reticulocyte counts and those performed with the counter (r = 0.893). Samples with large numbers of leucocytes, erythrocytes, or platelets did not interfere with the automated reticulocyte counting, and provided accurate and precise data.

Autoanalysis↗

Evaluation of erythropoietic/hematopoietic reconstitution after BMT by highly fluorescent reticulocyte counts compares favorably with traditional peripheral blood cell counting.

Highly fluorescent reticulocyte (HFR) counts and reticulocyte counts were analyzed daily using a Sysmex R-1000 automated reticulocyte counter after 42 BMT in children (median age 7 years, range 10 month-18.5 years). White blood cell levels were also analyzed daily using either traditional counting methods or, when levels were very low, cytocentrifuge preparations. Twenty-eight patients received autologous and 14 allogeneic BMT. After myeloablative therapy, HFR counts fell to zero and rose to 2% of the reticulocyte total after a median time of 10 days (range 6-23 days) post-autoBMT and 14 days (range 9-29 days) post-alloBMT. The appearance of HFR (at least 2% in two successive counts) preceded the attainment of 20 x 10(9)/l reticulocytes in 23 of 26 autoBMT by a median time of 3 days, and in 13 of 13 alloBMT with a median time of 4 days (p < 0.001). Two per cent HFR preceded the attainment of 0.5 x 10(9)/l neutrophils in the majority of BMT by a median time > 6 days (p < 0.001). The attainment of 0.05 x 10(9)/l monocytes was preceded by a rise in HFR in 12 of 26 autoBMT and in 7 of 13 alloBMT. Median times between 2% HFR and monocyte levels of 0.05 x 10(9)/l were respectively 2 (range 0- > 24) and 3 (range: 0- > 19) days after auto and alloBMT. These results show that the evaluation of erythropoiesis following BMT by means of HFR counting provides an early measure of hematopoietic reconstitution which is as precise and considerably more practical than monitoring the monocyte level.

Adolescent↗

Proficiency testing of reticulocyte counting in Ontario.

The reticulocyte count reflects the erythropoietic activity of the bone marrow and is thus useful in both the approach to the diagnosis of anemia and in monitoring bone marrow response to therapy. Traditionally, reticulocyte quantitation relied upon microscopic techniques; recently automated reticulocyte quantitation has become widely available. External quality assessment (EQA) of reticulocyte quantitation has not been widely reported; this paper presents data from reticulocyte EQA surveys conducted in Ontario between November 2000 and October 2004. Samples with normal and increased reticulocyte levels were obtained from adult donors and analyzed within 48 hours. We found that despite improved accuracy and precision, automated reticulocyte counting techniques do not translate into markedly improved inter-laboratory accuracy and precision. Further, we found that both microscopic and automated techniques can effectively differentiate between patients with normal and those with increased reticulocyte counts. Finally, we ascertained that reference intervals submitted with the initial surveys revealed that laboratories could have made erroneous clinical interpretations of their normal or elevated reticulocyte counts. The reestablishment of reference intervals by participants resulted in a marked improvement of the reference intervals submitted on subsequent surveys.

Adult↗