Comparison of the mechanical performance of ossiculoplasty using a prosthetic malleus-to-stapes head with a tympanic membrane-to-stapes head assembly in a human cadaveric middle ear model.

HYPOTHESIS: Ossiculoplasty using prosthetic reconstruction with a malleus assembly to the stapes head will result in better transmission of vibrations from the eardrum to the stapes footplate than reconstruction with a tympanic membrane assembly to the stapes head. Both types of reconstruction will be affected by tension of the prosthesis. BACKGROUND: Theories (and some clinical studies) that the shape of the normal tympanic membrane is important suggest that prosthetic reconstruction to the malleus performs better than reconstruction to the tympanic membrane. This has not been previously tested by directly measuring vibration responses in the human ear. Our previous work suggests that tympanic membrane assembly to the stapes head type prostheses performed best under low tension. This had not been previously tested for malleus assembly to the stapes head type prostheses. METHODS: Hydroxyapatite prostheses were used to reconstruct a missing incus defect in a fresh cadaveric human ear model. Two types of prostheses were used, one from the stapes head to the malleus (malleus assembly to the stapes head), the other from the stapes head to the tympanic membrane (tympanic membrane assembly to the stapes head). Stapes footplate center responses were measured using a laser Doppler vibrometer in response to calibrated acoustic frequency sweeps. RESULTS: Tension had a very significant effect on both types of prostheses in the lower frequencies. Loose tension was best overall. The malleus assembly to the stapes head type prostheses consistently performed better than the tympanic membrane assembly to the stapes head type prostheses when stratified for tension. CONCLUSION: Tension has a significant effect on prosthesis function. Malleus assembly to the stapes head type prostheses generally result in better transmission of vibrations to the stapes footplate than tympanic membrane assembly to the stapes head type prostheses.

Biomechanical Phenomena↗

Study of osteointegration of a titanium prosthesis to the stapes: observations on an accidentally extracted stapes.

BACKGROUND: Titanium is a well-established implant material, and its use in ossicular chain reconstruction during middle ear surgery is increasing. HYPOTHESIS: Bony fixation of titanium prostheses has to be considered using this material. Contact with bony structures of the middle ear may result in immobilization. In revision procedures, there is a potential risk of damaging or extracting adherent structures such as the stapes. METHODS: This is a case report of an accidentally extracted stapes resulting from bony fixation of a titanium prosthesis in revision tympanoplasty. The surgical specimen was examined by microscopy, histology, and scanning electron microscopy. Energy dispersive x-ray analysis was used to confirm the elemental composition of the extracted stapes and the titanium prosthesis. RESULTS: The prosthesis showed good biocompatibility at the implantation site, with signs of bone resorption of the stapes suprastructure. However, bony fixation of the undersurface of the prosthesis foot to the stapes footplate was confirmed by ultrastructural analysis. CONCLUSION: In revision tympanoplasty, bony fixation of the titanium prosthesis should be considered.

Audiometry, Pure-Tone↗

Bone cement ossiculoplasty: incus to stapes versus malleus to stapes cement bridge.

OBJECTIVE: In this study, our purpose was to evaluate results of our experience with bone cement repair of ossicular discontinuity between the incus and stapes and between the malleus and stapes. METHODS: Medical records of patients who underwent surgery for chronic otitis media between March 2000 and December 2002 were evaluated retrospectively. Fifty-seven patients who underwent bone cement ossiculoplasty and had appropriate follow-up data were included in the study. Bone cement reconstruction of the ossicular chain was performed 1) from incus to stapes (I-S) in the absence of long arm or lenticular process of the incus and 2) from malleus to stapes (M-S) in the absence of the incus. The clinical data of the patients were evaluated by otoscopic examination and audiometry. RESULTS: The graft take rate was 84.1%. I-S procedure was performed in 42 and M-S in 8 patients. Pre- and postoperative PTAs of all patients were compared, which showed a significant improvement in air PTA (p < 0.001) while bone PTA did not change (p > 0.05). In I-S and M-S groups, successful hearing restoration could be achieved in 78.6.1% and 87.5% of the patients, respectively. Hearing results of different aural pathologies (chronic otitis media and conductive hearing loss) and surgeries (tympanotomy and tympanoplasty with or without mastoidectomy) were not significantly different (p > 0.05). CONCLUSION: Bone cement ossiculoplasty offers cost effective and significant improvement in conductive hearing loss.

Adult↗

Eliminating the limitations of manual crimping in stapes surgery? A preliminary trial with the shape memory Nitinol stapes piston.

OBJECTIVE: Manual piston malcrimping in stapedotomy may be the major cause of the occurrence of the significant, interindividual variations of postoperative air-bone gap (ABG), air-bone gap closures (ABGC), and postoperative recurrences of conductive hearing loss. To eliminate the effects of manual crimping on stapedotomy outcomes, the self-crimping, shape memory alloy Nitinol stapes piston was investigated and hearing evaluated. STUDY DESIGN: Prospective, preliminary case-control study in a tertiary care referral center. METHODS: Sixteen patients with otosclerosis undergoing reversed stapedotomy using the Nitinol stapes piston were matched to reference patients out of our conventional titanium piston database. The effects of the self-crimping Nitinol piston on the postoperative ABGC, the postoperative air-bone gap (ABG) variations, and the postoperative short-term hearing results were investigated 3, 6 and 9 months postoperatively. These data were statistically compared with the results of the control patients in our titanium stapes piston database. RESULTS: The mean postoperative ABG and the interindividual variations of the postoperative ABG were significantly smaller in the Nitinol group, the extent of ABGC greater in the Nitinol piston group, but not significant. The postoperative short-term stability of ABGC was similar in both groups. No infections or adverse reactions occurred during follow-up. CONCLUSION: Our preliminary results suggest that the self-crimping shape memory alloy Nitinol stapes piston eliminates the limitations of manual malcrimping in stapedotomy, thus optimising the surgical procedure. This allows reliable, safe, and consistent air-bone-gap closure in patients with otosclerosis up to 1 year after surgery.

Adult↗

Ossicular reconstruction in tympanoplasty - mobile stapes without crural arches, fixed stapes with and without crural arches.

A description of ossicular reconstruction in problems with the stapes using autograft and/or homograft ossicles is given. The inverted stapes is employed for otosclerosis and tympanosclerosis. The two ossicle reconstruction is used in cases of a mobile footplate with absent crural arches. The reshaped incus is repositioned between the malleus handle and oval window when the stapes is fixed and there also exists a lateral ossicular chain defect. Loose connective tissue is an effective seal for the oval window and is a means of stabilizing ossicular functions.

Humans↗

Missing stapes and stapes-replacing prosthesis.

Our study of 205 ears with missing stapes, secondary to some type of chronic ear disease, showed that only 40% of such ears are suitable for ossiculoplasty. The remaining 60% are unsuitable because of a fixed footplate, severe atelectasis, hearing better than 25 dB (these patients do not need the operation), or poor discrimination. A new stapes replacement prosthesis (SRP), which we term Tabor, is described for use where indicated. The prosthesis has two parts: The lower part (or base) is made of a broad inorganic, biocompatible material (Teflon). This part fits and covers most of the footplate, ensuring maximal stability. The upper part of the prosthesis is made of autograft or homograft bone--usually a malleus head--the contact of which with the drum prevents extrusion. In twelve out of fourteen ears insertion of this prosthesis was successful; the average postoperative air conduction went from 56 dB to 29 dB, leaving an average air-bone gap of 16 dB. The bone conduction also improved, from an average of 20 dB to 13 dB.

Bone Conduction↗

Stapes surgery.

Explore the source record for details and available documents.

Ear Ossicles↗