PubMed HealthSearch

SEARCH · PubMed Health

Results for “extreme rays”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Partial enumeration of extreme rays in metabolic networks using bit pattern trees.

Extreme ray analysis of metabolic networks, even though very powerful, is currently limited to smaller metabolic networks. Some approaches to generating partial sets of extreme rays exist, but the computational efficiency of the so-called double-description method is yet to be exploited. Previous work highlighted the possibility of sampling within its iterations, enabling partial enumeration for double-description based methods. However, these approaches severely lack computational efficiency to be a suitable alternative. In this work, the highly efficient bit pattern trees are used within the sampling framework to significantly enhance its output and speed. Combined with the recent revision of the Canonical Basis Approach (CBA), our approach outperforms the other tested methods under the reported benchmark conditions even for a full enumeration study, requiring only half the computation time. In addition, a filter setting allows the memory demand to be scaled down while retaining high efficiency. However, some issues with the combinatorial explosion of candidates still persist and are further investigated. This study therefore puts forward a novel, double description-based alternative to partial enumeration of extreme rays. Further improvements in memory efficiency would allow this promising approach to scale powerful extreme ray-based analyses to genome-scale metabolic networks.

constraint-based modelling

Feulgen type staining with Hoffmann's violet-SO2 under exposure to UV rays.

The paper contains an account of the use of Hoffmann's violet-SO2 under exposure to UV rays during staining acid-hydrolysed DNA of mammalian tissue nuclei. Preparations stained with Hoffmann's violet-SO2 without exposure to UV rays reveal extremely pale violet nuclei but when stained under the influence of UV rays show a considerably faster reaction resulting in a very much deeper staining of the nuclei. Sections after staining with this dye-reagent require n-butanol as differentiating reagent. Possible interpretation for the increase in staining ability of this dye-reagent under exposure to UV rays has been elucidated and the reason for considering the reaction as Feulgen type has been discussed.

Adrenal Glands

[The part taken by X-ray investigation for closed soft tissue injuries on the extremities (author's transl)].

Special X-ray pictures taken of soft tissues for the treatment of closed soft tissue injuries on the extremities, give valuable diagnostic advises. Rupture on the surface of muscles, the lesion to the tendon Achilles and the lig. patellae proprium, tumours, muscle waisting following plexus or periferial nerve lesions etc. by X-ray investigation can be exactly delineated and the site, extension and type of damage defined.

Adult

Reparable and irreparable damage in yeast cells induced by sparsely ionizing radiation.

It is shown that in diploid yeast there are significant differences in the extent of irreparable damage after irradiation with X-rays, 60Co-gamma-rays and 30 MeV electrons. At extremely low dose rates, 60Co-gamma-rays were found to produce almost no irreparable damage at least up to 1200 Gy. X-rays, however, at the same low dose rate caused irreparable damage in the same dose range yielding a surviving fraction of 0.25 at 1200 Gy. For irradiations at high dose rate followed by liquid holding recovery the relative biological effectiveness of X-rays amounted to at least 4 for absorbed doses of up to 1000 Gy. With 30 MeV electrons at high dose rates an accumulation of sublethal and potentially lethal damage resulting in irreparable damage occurred above 1000 Gy. It is suggested that irreparable damage in yeast is due to a cooperative effect of neighbouring track ends.

DNA Repair

[X-ray-examination-time during implantation of pervenous leads for permanent cardiac pacing (author's transl)].

From February 1974 to December 1975 we performed 295 pacemaker operations. 165 of those were primary implantations of pervenous leads for permanent cardiac pacing. The X-ray examination time was between 0.1 and 17.0 minutes, their mean value was 2.6, their median 1.7 minutes. In those 165 cases there was a dislocation of the lead in 10.9 percent. Although our X-ray examination time was extremely short however in comparison with the literature we found no arise of our dislocation rate. Some hinces to keep radiation small are discussed.

Electrodes, Implanted

The chest x-ray in acute left ventricular power failure: an aid to determining prognosis of patients supported by intraaortic balloon pumping.

Serial chest x-rays were used as a means of evaluating the hemodynamic status of 43 patients in acute left ventricular power failure (LVPF) complicating acute myocardial infarction who were assisted with balloon pumping. The following findings were reported: 1. In patients with acute myocardial infarction, prediction of the hemodynamic status on the basis of chest x-rays is less reliable when severe LVPF is present as a complication. 2. The incidence and severity of roentgenographic findings of congestive heart failure and pulmonary edema are increased in patients with severe LVPF compared to patients with uncomplicated myocardial infarction. 3. Improvement in the roentgenographic degree of heart failure with positive clinical and hemodynamic responses to 24 hr or less of balloon pumping is an indication that patients in severe acute LVPF may survive. Patients with deteriorating or unchanging chest x-ray findings have an extremely poor prognosis. These patients should be evaluated by cardiac catheterization and coronary arteriography to determine the appropriateness of emergency surgical correction.

Acute Disease

Chromosomal mobilization from a recA mutant of Pseudomonas putida.

A methyl methane sulfonate sensitive mutant of P. putida strain PpG1 is also extremely sensitive to UV-rays, compared to parent wild type cells. This mutant behaves typically as recombination less (recA) mutants of Escherichia coli and Pseudomonas aeruginosa, since as a recipient, it exhibits extremely low frequency of recombination following conjugational, transductional, and transformational gene transfer. Sex factor plasmids such as K-XYL or TOL can mobilize chromosomal genes equally well both from recA+ and recA801 donor cells, suggesting that host recombination functions are not necessary for mobilization of chromosomal genes by such plasmids.

Bacterial Proteins

A rapid and precise method for the determination of vitamin D3 in rat skin by high-performance liquid chromatography.

In order to develop the investigations into photobiogenesis of vitamin D3, a rapid and precise method for the determination of the vitamin in rat skin was established by using high-performance liquid chromatography (HPLC). The proposed method included saponification of small pieces of rat skin, extraction of the unsaponifiable matter and application to HPLC using "Zorbax SIL" (straight-phase) as an adsorbent and 0.5% isopropanol in n-hexane as a mobile phase. The applicable lower limit of the method was 2ng of vitamin D3/cm2 of subcutaneous tissue-removed skin and it was possible to assay a concentration higher than 2 ng/cm2. The proposed method was applied to determine the content of vitamin D3 in rat skin obtained from in vivo and in vitro irradiation experiments. In the in vitro experiment, the yield of vitamin D3 increased in proportion to the irradiation time. On the other hand, the yield in the in vivo experiment showed a proportional increase similar to the in vitro experiment until 60 min irradiation, while a nearly constant value was obtained by irradiation for longer than 60 min. When the rat skin obtained from the in vitro experiment was irradiated with monochromatic UV rays in the range s60-350 nm, the most effective wavelength for the formation of vitamin D3 was confirmed to be 303 nm, which differs from the result obtained from the experiment in a test tube (295 nm). Moreover, the yield of vitamin D3 by irradiation with UV rays below 288 nm was extremely low, which again differed from the results of a test tube experiment. These differences were thought to be due to the filter effect of the malpighian layer in the epidermis of rat skin.

Animals

[Bone mineral estimation (Hydroxyl apatite equivalent) by direct measurement of photo absorption in the upper extremity (phalanges, radius and ulna) (author's transl)].

The x-ray source of the apparatus developed by the authors for bone mineral estimations consists of a small anode tube with a silver anode. The value of the procedure has been tested by in vitro and in vivo experiments. The in vitro measurements were carried out on a bone reference system consisting of a model bone (Reiss) as well as on a macerated tibia embedded in a resin (Heuck). The results were compared with the values obtained by Rassow. It has been shown that the artificial resin is of only limited value as a connective tissue equivalent. The method of mineral estimation using phalanges is described and its reproducibility was tested on 17 parameters. The absorption coefficient of the spongiosa proved to be particularly critical. Finally, measurements, using the forearm, by Cameron's method are discussed briefly.

Absorption

[Diagnosis and treatment of birth injuries of the cervical portion of spine and spinal cord in newborn infants].

Experience in the treatment of 200 newborns with birth spinal cervical trauma in the acute period (under 3 weeks of age) is generalized. Forty-nine infants died; circulatory disorders and edema of the spinal cord were the prevalent morphological findings. The clinical manifestations were pareses of the upper extremities and, less frequently, truncal disorders. X-ray examination revealed spinal injury, epidural hematomas and edema of the spinal cord. Treatment included reduction of the dislocated vertebrae with subsequent immobilization of the cervical spine and rehabilitation therapy. Improvement and, sometimes, total normalization of the functions of the spinal cord were achieved.

Birth Injuries

Prenatal diagnosis of achondrogenesis.

An achondrogenic fetus, in whom the diagnosis was made prior to delivery by plain abdominal X-rays, is presented. The intrauterine characteristic roentgenographic manifestations are the short dense tubular bones of the extremities. An early diagnosis in fetuses with this disease can be made on a plain abdominal X-ray in the 22nd-24th week of gestation.

Abortion, Induced

Periostitis associated with myelofibrosis.

Two patients with myelofibrosis developed fever, leg pain and periostitis. The first patient had myelofibrosis with myeloid metaplasia and was symptomatic for months before x-rays showed periosteal new bone formation in the lower extremities. He subsequently developed periostitis of both upper extremities. Radiation of the lower extremities resulted in significant pain relief. The second patient had a past history of polycythemia vera and experienced painful periostitis of the tibiae and fibulae. 99mTechnetium pyrophosphate bone scans showed increased uptake in the involved bones in both patients. Asymptomatic or painful periostitis may be related to the increased bone blood flow associated with myelofibrosis. Radiation can afford successful palliation in the severely symptomatic patient.

Diagnosis, Differential

The changes in configuration of the rib cage and abdomen during breathing in the anaesthetized cat.

1. The external surface of the rib cage and abdominal wall in anaesthetized cats was surgically exposed in order to record their movements cinematographically in spontaneous breathing and in paralysed cats, during artificial positive pressure ventilation. 2. Cine-stereophotography was used to allow the recording of the movements of a set of markers placed on the external surface of the trunk wall and the corresponding stereometric data were numerically and graphically processed into three-dimensional drawings. The cine-film frames corresponding to the phases of maximum inflation and deflation of the lungs were analysed to reveal the changes in configuration associated with the respiratory movements of the trunk wall. 3. The changes in shape of the diaphragm and the diaphragm and the displacements of the abdominal viscera between extreme inflation and deflation were recorded by X-ray photography. 4. During spontaneous inspiratory movements, the ribs rotated outwards and rostrally about the costovertebral joints, bringing about an increase in the transverse dimensions of the cage all along its length; these movements were accompanied by a clear-cut caudad displacement of the sternum, caused by the straightening of the costal cartilages and by the widening of the angles defined at sternochondral joints between the sternum and each of the costal cartilages. 5. Neuromuscular blockade abolished muscle tone in the trunk wall, allowing the weight of the viscera markedly to deform its configuration. 6. The inspiratory rib movements of the paralysed animal during artificial inspiration were similar to those during spontaneous breathing but the movements of the sternum were inverted and showed small cranial displacements. 7. The loss of muscular tone under neuromuscular blockade made the abdominal wall more compliant than the rib cage to the positive lung pressure and allowed greater mobility of the viscera with consequent distortion of the shape of the diaphragm. 8. The role of rib cage muscle tone in meeting requirements of purely configurational character in such a shell-like structure is discussed in relation to the optimal mechanical performance of the diaphragm.

Abdominal Muscles

Influence of a prolonged period of low-dosage x-rays on the optic and ultrastructural appearances of cataract of the human lens.

Human lenses extracted for cataract 26 years after long-term exposure to an imperfectly shielded radium source were examined by slit-lamp photography, thin-section light microscopy, and electron microscopy. Anterior epithelial cells were fibroblast-like, and germinal epithelium and vacuolated cortical fibres had accumulated at the equator. A zone of light scatter at the anterior pole corresponded to an area of breakdown of cortical lens fibres, where unusual feathery fibres were orientated perpendicular to the lens surface. Two zones of light scatter separated by a 250-microM clear interval were seen in the posterior cortex. The zone at the posterior pole corresponded to an area of fibre liquefaction and large rounded membrane whorls, while the deeper zone comprised small flattened membrane whorls. The characteristic plaques of swollen abnormal cells described in previous histological studies of x-ray cataract were not present. This and other differences probably reflect the extremely long time course and repeated subliminal doses to which the patient was exposed.

Cataract

Calcium containing particles in mitochondria of heart muscle cells as shown by cryo-ultramicrotomy and X-ray microanalysis.

Mitochondria of normal myocardial cells of the sand rat and the mouse as well as of the left ventricle of man, have been examined for their content of calcium. Ultrahistochemistry and X-ray microanalysis revealed two basically different inclusions: Osmiophilic mitochondrial granules and spherical mitochondrial particles. Osmiophilic mitochondrial granules were found in conventionally fixed and plastic embedded tissues as well as in cryosections of chemically fixed and sucrose infused tissues. Such granules lacked inert electron density and probably consisted mainly of unsaturated lipids. X-ray spectra obtained from these tissues revealed no peaks for calcium. Spherical mitochondrial particles were present in dry-cut cryo-sections of N2-frozen tissues not treated by fixatives and/or cryoprotectants. These particles were deeply electron dense in unstained, freeze-dried cryo-sections. They usually measured from 600 A-900 A in diameter in the normal myocardium of the sand rat and the mouse and from 250 A-400 A in diameter in the left ventricular myocardium of man. Significant calcium peaks could be identified in the X-ray spectra of these particles, whereas none occurred in the analyses of other tissue regions. Potassium was detected with about equal frequency in the particles and in other parts of the tissue. On the basis of the inert electron density of the particles and their absence in chemically fixed tissues as well as of the results of the X-ray analysis, it is concluded that they contain precipitates of extremely labile ions of mitochondrial calcium.

Animals