Analysis of the Listeria cell wall proteome by two-dimensional nanoliquid chromatography coupled to mass spectrometry.

Genome analyses have revealed that the Gram-positive bacterial species Listeria monocytogenes and L. innocua contain a large number of genes encoding surface proteins predicted to be covalently bound to the cell wall (41 and 34, respectively). The function of most of these proteins is unknown and they have not even been identified biochemically. Here, we report the first characterization of the Listeria cell wall proteome using a nonelectrophoretic approach. The material analyzed consisted of a peptide mixture obtained from a cell wall extract insoluble in boiling 4% SDS. This extract, containing peptidoglycan (intrinsically resistant to proteases) and strongly associated proteins, was digested with trypsin in a solution with 0.01% SDS, used to favor protein digestion throughout the peptidoglycan. The resulting complex peptide mixture was fractionated and analyzed by two-dimensional nanoliquid chromatography coupled to ion-trap mass spectrometry. A total of 30 protein species were unequivocally identified in cell wall extracts of the genome strains L. monocytogenes EGD-e (19 proteins) and L. innocua CLIP11262 (11 proteins). Among them, 20 proteins bearing an LPXTG motif recognized for covalent anchoring to the peptidoglycan were identified. Other proteins detected included peptidoglycan-lytic enzymes, a penicillin-binding protein, and proteins bearing an NXZTN motif recently proposed to direct protein anchoring to the peptidoglycan. The marked sensitivity of the method makes it highly attractive in the post-genome era for defining the cell wall proteome in any bacterial species. This information will be useful to study novel protein-peptidoglycan associations and to rapidly identify new targets in the surface of important bacterial pathogens.

Cell Wall↗

Method to site-specifically identify and quantitate carbonyl end products of protein oxidation using oxidation-dependent element coded affinity tags (O-ECAT) and nanoliquid chromatography Fourier transform mass spectrometry.

Protein oxidation is linked to cellular stress, aging, and disease. Protein oxidations that result in reactive species are of particular interest, since these reactive oxidation products may react with other proteins or biomolecules in an unmediated and irreversible fashion, providing a potential marker for a variety of disease mechanisms. We have developed a novel system to identify and quantitate, relative to other states, the sites of oxidation on a given protein. This presents a significant advancement over current methods, combining strengths of current methods and adding the abilities to multiplex, quantitate, and probe more modified amino acids. A specially designed Oxidation-dependent carbonyl-specific Element-Coded Affinity Mass Tag (O-ECAT), AOD, ((S)-2-(4-(2-aminooxy)-acetamido)-benzyl)-1,4,7,10-tetraazacyclododecane-N,N',N' ',N'''-tetraacetic acid, is used to covalently tag the residues of a protein oxidized to aldehyde or keto end products. O-ECAT can be loaded with a variety of metals, which yields the ability to generate mass pairs and multiplex multiple samples. The O-ECAT moiety also serves as a handle for identification, quantitation, and affinity purification. After proteolysis, the AOD-tagged peptides are affinity purified and analyzed by nanoLC-FTICR-MS (nanoliquid chromatography-Fourier transform ion cyclotron resonance-mass spectrometry), which provides high specificity in extracting coeluting AOD mass pairs with a unique mass difference and allows relative quantitation based on isotopic ratios. Using this methodology, we have quantified and mapped the surface oxidation sites on a model protein, recombinant human serum albumin (rHSA) in its native form (as purchased) and after FeEDTA oxidation both at the protein and amino acid levels. A variety of modified amino acid residues including lysine, arginine, proline, histidine, threonine, aspartic, and glutamic acids, were found to be oxidized to aldehyde and keto end products. The sensitivity of this methodology is shown by the number of peptides identified, twenty peptides on the native protein and twenty-nine after surface oxidation using FeEDTA and ascorbate. All identified peptides map to the surface of the HSA crystal structure, validating this method for identifying oxidized amino acids on protein surfaces. In relative quantitation experiments between FeEDTA oxidation and native protein oxidation, identified sites showed different relative propensities toward oxidation, independent of amino acid residue. This novel methodology not only has the ability to identify and quantitate oxidized proteins but also yields site-specific quantitation on a variety of individual amino acids. We expect to extend this methodology to study disease-related oxidation.

Affinity Labels↗

Separation of enantiomers by nanoliquid chromatography and capillary electrochromatography using a bonded cellulose trisphenylcarbamate stationary phase.

A cellulose trisphenylcarbamate-bonded chiral stationary phase was applied to nano-liquid chromatography (nano-LC) and capillary electrochromatography (CEC) with nonaqueous and aqueous solutions as the mobile phases. Several chiral compounds were successfully resolved on the prepared phase by nano-LC. The applicability of nonaqueous CEC on a cellulose derivative stationary phase was investigated with the organic solvents methanol, hexane, 2-propanol, and tetrahydrofuran (THF) containing acetic acid, as well as triethylamine as the mobile phases. Enantiomers of warfarin and praziquantel were baseline-resolved with plate numbers of 82,300 and 38,800 plates/m, respectively, for the first eluting enantiomer. The influence of applied voltage, concentration of nonpolar solvent, apparent pH, and buffer concentration in the mobile phase on the electroosmotic flow (EOF) and the mobility of the enantiomers was evaluated. Enantioseparations of trans-stilbene oxide and praziquantel were also achieved in aqueous CEC with plate numbers of 111,100 and 107,400 plates/m, respectively, for the first eluting enantiomer. A comparison between nonaqueous CEC and aqueous CEC based on a cellulose trisphenylcarbamate stationary phase was discussed. Pressure-assisted CEC was examined for the chiral separation of praziquantel and faster analysis with high enantioselectivity was acquired with the proper pressurization of the inlet vial.

Carbamates↗

Separation techniques hyphenated to electrospray-tandem mass spectrometry in proteomics: capillary electrophoresis versus nanoliquid chromatography.

Liquid chromatography (LC) nanoelectrospray-tandem mass spectrometry (MS/MS) is a key technology for the study of proteomics, with the main benefit to the characterization of sensitive peptides from complex mixtures. Capillary electrophoresis coupled to mass spectrometry (MS) has been taken into consideration sporadically due to the highly efficient separation and ability to handle low sample amount, yet classified as being less sensitive with respect to analyte concentration. The limitation in capillary zone electrophoresis (CZE) injection volumes can be overcome by on-line solid-phase extraction (SPE). Such an on-line SPE-CZE system was explored in combination with an ion trap (IT) mass spectrometer. Thus, it was possible to inject more than 100 microL sample solution on to the CZE capillary. Concentration limits of detection as low as 100 amol/microL were demonstrated for a peptide standard. This SPE-CZE-microelectrospray ionization (ESI)-MS/MS setup was compared directly to nanoLC/nanoESI using the same sample of a tryptic digest of bovine serum albumin (BSA) as a reference standard. Measurements were made on one IT mass spectrometer with identical acquisition parameters. Both chromatography systems enabled the separation and detection of low levels of peptides from a mixture of moderate complexity, with most peptides identified using both techniques; however, specific differences were obvious. The nanoLC-MS is about five times more sensitive than the CZE-MS, yet the difference was less pronounced than expected. The CZE-MS technique showed reduced loss of peptides, especially for larger peptides (missed cleavages) and is about four times faster than the nanoLC-MS approach.

Amino Acid Sequence↗

Separation of tocopherols by nano-liquid chromatography.

Nanoliquid chromatography (nano-LC) was used for the separation of tocopherols (delta-, gamma-, alpha-TOH), alpha-tocopherol acetate (alpha-TOH-Ac) and an antioxidant compound, namely butylated hydroxytoluene (BHT) used to prevent TOHs autoxidation. The separation was carried out in a fused silica capillary of 100 microm I.D. and 375 microm O.D. packed in our laboratory with RP18 silica stationary phase of either 5- or 3-microm diameter (23-cm long). The mobile phase was composed by mixtures of methanol (MeOH), acetonitrile (MeCN) and water. Typical analyses time for the separation of all the five components of the mixture were 6-9 min depending on the composition of the mobile phase. Efficiency and resolution were strongly influenced by the particle diameter and the highest Rs and N/m values were observed using 3-microm RP18 particles. Experiments performed with capillaries packed with 3-microm RP18 particles provided good limit of detection (LOD) and limit of quantification (LOQ) (for delta-, gamma-TOH, alpha-TOH-Ac were 4 and 8 microg/ml, while for alpha-TOH were 6 and 10 microg/ml, respectively). The optimized method was applied to extracts of serum and pharmaceutical preparation containing alpha-TOH and alpha-TOH-Ac.

Chromatography, Liquid↗

Identification of two-dimensionally separated human cerebrospinal fluid proteins by N-terminal sequencing, matrix-assisted laser desorption/ionization--mass spectrometry, nanoliquid chromatography-electrospray ionization-time of flight-mass spectrometry, and tandem mass spectrometry.

Optimal application of biological mass spectrometry (MS) in combination with two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) of human cerebrospinal fluid (CSF) can lead to the identification of new potential biological markers of neurological disorders. To this end, we analyzed a number of 2-D PAGE protein spots in a human CSF pool using spot co-localization, N-terminal sequencing, matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) and nanoliquid chromatography-electrospray ionization-time of flight-mass spectrometry (nanoLC-ESI-TOF-MS) with tandem MS switching. Our constructed CSF master contained 469 spots after image analysis and processing of 2-D gels. Upon visual inspection of our CSF master with the CSF pattern available on the ExPASy server, it was possible to locate and annotate 15 proteins. N-terminal sequence analysis and MALDI-MS peptide mass fingerprint analysis of both silver- and Coomassie Brilliant Blue (CBB) G-250-stained protein spots after in situ trypsin digest not only confirmed nine of the visually annotated spots but additionally resolved the identity of another 13 spots. Six of these proteins were not annotated on the 2-D ExPASy map: complement C3 alpha-chain (1321-1663), complement factor B, cystatin C, calgranulin A, hemoglobin beta-chain, and beta-2-microglobulin. It was clear that MALDI-MS identification from CBB G-250-stained, rather than from silver-stained, spots was more successful. In cases where no N-terminal sequence and/or no clear MALDI-MS result was available, nanoLC-ESI-TOF-MS and tandem MS automated switching was used to clarify and/or identify these protein spots by generating amino acid sequence tags. In addition, enrichment of the concentration of low-abundant proteins on 2-D PAGE was obtained by removal of albumin and immunoglobulins from the CSF pool using affinity chromatography. Subsequent analysis by 2-D PAGE of the fractionated CSF pool showed various new silver-stainable protein spots, of which four were identified by nanoLC-ESI-TOF-MS and tandem MS switching. No significant homology was found in either protein or DNA databases, indicating than these spots were unknown proteins.

Amino Acid Sequence↗

Nanoliquid chromatography-mass spectrometry of oligosaccharides employing graphitized carbon chromatography on microchip with a high-accuracy mass analyzer.

The nanoLC separations of oligosaccharides using microchip-based columns are described. Mixtures of alditols from mucins and human milk are separated on graphitized carbon. The nanoLC-MS device showed high mass accuracy for the oligosaccharides ranging between 1 and 6 ppm on routine analyses. The high mass accuracy readily allowed identification of oligosaccharide peaks and the determination of their compositions. High retention time reproducibility was exhibited by the microchip LC. Little variation was observed for standard sample either alone or in a complex heterogeneous mixture. The nanoLC-MS exhibits excellent capabilities in profiling mixtures of oligosaccharides.

Carbon↗

Proteomic study of human bronchoalveolar lavage fluids from smokers with chronic obstructive pulmonary disease by combining surface-enhanced laser desorption/ionization-mass spectrometry profiling with mass spectrometric protein identification.

Bronchoalveolar lavage fluid (BALF) is an important diagnostic source to investigate cellular and molecular changes in the course of lung disorders. The pattern of soluble proteins in BALF obtained from patients at different stages of respiratory disorders may provide deeper insights in the molecular mechanisms of the disease. We used surface-enhanced laser desorption/ionization mass spectrometry (MS) for differential protein display combined with reversed-phase chromatography and subsequent matrix-assisted laser desorption/ionization-MS or nanoliquid chromatography MS/MS analysis for protein identification to compare the protein pattern of BALF samples obtained from ten smokers suffering from chronic obstructive pulmonary disease (COPD), eight clinically asymptomatic smokers, and eight nonsmokers without pulmonary disease. In this context, we were able to identify small proteins and peptides, either differentially expressed or secreted in the course of COPD or in a direct response to cigarette smoke. The concentrations of neutrophil defensins 1 and 2, S100A8 (calgranulin A), and S100A9 (calgranulin B) were elevated in BALFs of smokers with COPD when compared to asymptomatic smokers. Increased concentrations in S100A8 (Calgranulin A), salivary proline-rich peptide P-C, and lysozyme C were detected in BALFs of asymptomatic smokers when compared to nonsmokers, whereas salivary proline-rich peptide P-D and Clara cell phospholipid-binding protein (CC10) were reduced in their concentration. The identified proteins and peptides might be useful in the future as diagnostic markers for smoke-induced lung irritations and COPD.

Bronchoalveolar Lavage Fluid↗

Tryptic digest mapping by gradient capillary electrochromatography.

A high performance liquid chromatography (HPLC) system complemented with T-split, capillary detection cell and a high voltage power supply was used for peptide mapping by gradient electrochromatography and nanoliquid chromatography (nano-LC). With capillary columns of 100 microm ID, 6 cm packed with octadecylated 1.5 microm silica particles, the typical analysis time was approximately 10-15 min. The resolution of a tryptic digest of cytochrome c obtained by electrochromatography at 100 kV/m was superior compared to the analysis by nano-LC. Bubble formation caused by Joule heating at currents up to 100 microA was successfully suppressed by using a resistor capillary of 25 microm ID connected to the outlet of the packed column.

Chromatography, Liquid↗

A robust approach for the analysis of peptides in the low femtomole range by capillary electrophoresis-tandem mass spectrometry.

A capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) approach has been developed for routine application in proteomic studies. Robustness of the coupling is achieved by using a standard coaxial sheath-flow sprayer. Thereby, greater stability than nanoelectrospray ionization-mass spectrometry coupling of sheathless capillary electrophoresis or nanoliquid chromatography (nano-LC) is achieved, resulting in stable operation for several weeks and unattended overnight sequences. The applied sheath flow is reduced to 1-2 microL/min in order to increase sensitivity. Standard peptides and those of digests of standard proteins and gel-separated proteins can be detected in the low femtomole range (full scan and MS/MS). Detection limits are found to be as low as 500 amol. Low femtomole amounts are required for unequivocal identification by MS/MS experiments in the ion trap and subsequent database search. By applying a simple pH-mediated stacking the concentration sensitivity can be lowered to some tens of fmol/microL (nM), depending on capillary size. This sensitivity is close to published values for sheathless CE-MS and nano-LC-MS, respectively (a comparison to reference values is presented). Moreover, with capillaries of about 50 cm in length separations in less than 10 min are possible resulting in a throughput of up to four analyses per hour. This is a factor of 4-12 times faster than nano-LC separation, being the state-of-the-art techniques for proteomic studies.

Animals↗

Proteomic characterization of the acquired enamel pellicle under acidic challenges at early and mature formation stages.

OBJECTIVES: This study aimed to characterize acquired enamel pellicle (AEP) proteomic changes after exposure to citric acid (CA) and hydrochloric acid (HCl) under different pellicle formation times (3 and 120&#x202f;min) in the same volunteers. DESIGN: Nine healthy volunteers participated in this randomized crossover in vivo study. The AEP was allowed to form for 3 or 120&#x202f;min and subsequently exposed for 10&#x202f;s to deionized water (control), 1% CA (pH 2.5), or 0.01&#x202f;M HCl (pH 2.0). Pellicle samples were collected, followed by protein extraction, tryptic digestion, and analysis by nanoliquid chromatography (nanoLC) coupled to mass spectrometry (MS) with MSE (data-independent acquisition; nanoLC-MS&#x1d31;). Label-free quantitative proteomics were performed for relative quantification using t-test (p&#x202f;<&#x202f;0.05). RESULTS: At 120&#x202f;min, CA exposure markedly reduced several typical AEP proteins, especially acidic proline-rich proteins (PRPs). Conversely, basic PRPs were upregulated, suggesting acid-resistance protein signature. At 3&#x202f;min, basal-layer proteins (PRPs, cystatins, histatins and mucins) were more abundant. Hemoglobins increased 6-8-fold (up to 150-fold in 3&#x202f;min control), suggesting association with early pellicle formation and an acid-resistant protein signature. CA exposures for 120&#x202f;min also upregulated typical AEP proteins (PRPs, mucins, cystatins, immunoglobulins), while HCl exposure depleted albumins and lactotransferrin. CONCLUSION: Intrinsic and extrinsic acids induce distinct proteomic signatures in the AEP. Hemoglobin and PRPs appear consistently enriched in the early pellicle layer, reflecting an initial acid-resistant protein signature. These findings provide new insights into the molecular remodeling of the AEP following intrinsic and extrinsic acid exposure, highlighting proteins potentially involved in early-stage pellicle formation.

Humans↗

Benchmarking the OptiSpray-&#x3bc;PAC Workflow against a Traditional Nanospray Capillary Interface for Multiplexed Quantitative Proteomics.

Nanoflow liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) underpins modern quantitative proteomics, yet the column-to-mass spectrometer interface remains an important yet often underappreciated determinant of analytical depth, sensitivity, and reproducibility. Here, we benchmark an integrated workflow comprising the newly developed OptiSpray ion source and a micropillar array column (&#x3bc;PAC) cartridge against a conventional Nanospray Flex Source with an Accucore resin-packed capillary column. We performed a TMTpro 18-plex experiment across nine human cell lines on a FAIMS Pro-equipped Orbitrap Exploris 480. Following basic-pH reversed-phase fractionation, 12 fractions were analyzed on both workflow configurations under matched chromatographic gradient and acquisition conditions. Across both configurations, we quantified >9000 protein groups with highly comparable quantitative reproducibility and principal component clustering. Direct comparison of protein abundance ratios across cell lines showed agreement (Pearson R2 &#x2248; 0.7-0.8) without systematic bias. These results were achieved without workflow-specific optimization of the OptiSpray-&#x3bc;PAC platform, enabling direct transfer of established acquisition methods. Despite differences in column architecture, both configurations delivered comparable proteome coverage and quantitative fidelity. These findings establish the OptiSpray-&#x3bc;PAC workflow as a standardized alternative to conventional capillary-based interfaces, offering simplified operation while preserving quantitative performance.

Humans↗

Identification of peroxisomal membrane proteins of Saccharomyces cerevisiae by mass spectrometry.

The identification of peroxisomal membrane proteins is very important to understand the import mechanisms of substrates and proteins into these organelles and the pathogenesis of human peroxisomal disorders like the Zellweger Syndrom. Peroxisomal membrane proteins were identified after separation by gel electrophoresis, tryptic digestion and mass spectrometric analysis. Using matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) and nanoliquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS), it was possible to identify 45 proteins of isolated yeast peroxisomal membranes.

Amino Acid Sequence↗

Two-dimensional electrophoresis protein profiling and identification in rat bronchoalveolar lavage fluid following allergen and endotoxin challenge.

The protein content of bronchoalveolar lavage fluid (BALF) from actively sensitised Brown Norway (BN) rats challenged with allergen (ovalbumin, OA) and from naïve Brown Norway rats challenged with endotoxin (lipopolysaccharide, LPS) was analyzed and compared to healthy controls treated with vehicle only. BALF proteins were analyzed by one-dimensional (1-D) and two-dimensional (2-D) gel electrophoresis and identified by peptide mass fingerprinting matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) or nanoliquid chromatography-tandem MS (nanoLC-MS/MS) after in-gel trypsin digestion of selected 2-D gel spots. Our study shows that the BALF protein profile is significantly different in animals after allergen (OA) or endotoxin (LPS) challenge as compared to controls, concerning the content of proteins derived from plasma or produced locally in the lung. In both challenges the following proteins presented patterns which differed qualitatively compared to control: T-kininogen I and II, alpha-1-antitrypsin, calgranulin A, fetuin A and B, and haptoglobin. Other proteins were diminished in both challenges, such as Clara cell 10 kDa secretory protein (CC10) and pulmonary surfactant associated protein B (SP-B); c-reactive protein increased in the OA-challenge and decreased in the LPS-challenge, and pulmonary surfactant associated protein A (SP-A) was decreased in the OA-challenge and was not significantly changed in the LPS-challenge. The identified proteins could be important not only for the diagnosis but have also interesting implications for medical treatment of lung inflammatory conditions. Furthermore, even if based on a limited number of animals, our results are of interest for the identification of lung protein markers and a better understanding of the mechanisms involved in the pathogenesis of lung diseases.

Allergens↗

Application of fluorescence difference gel electrophoresis saturation labelling for the analysis of microdissected precursor lesions of pancreatic ductal adenocarcinoma.

In order to identify new molecular markers for pancreatic intra-epithelial neoplasias (PanINs), the precursor lesions of pancreatic ductal adenocarcinoma, we established a proteomics approach analysing microdissected PanIN cells. Due to the limited amount of proteins available from microdissection, we developed a procedure including fluorescence dye saturation labelling in combination with high resolution two-dimensional gel electrophoresis. With this procedure we were able to analyse proteins extracted from 1000 microdissected cells with a high resolution of up to 2500 protein spots. Using protein lysates from the pancreatic carcinoma tissue as a reference proteome, we were able to successfully identify the proteins. Thus, we could match approximately 2200 protein spots (92%) of the microdissected sample proteome to the reference proteome for protein identification using matrix-assisted laser desorption/ionisation-time of flight mass spectrometry and nanoliquid chromatography-electrospray ionisation tandem mass spectrometry after in-gel digestion. The first proteome analysis of microdissected PanIN-2 grades revealed eight differentially expressed proteins. The differential expression of the three actin filament-associated proteins--transgelin, vimentin and MRCL3 as well as actin itself--indicates a relevant role of the actin cytoskeleton during pancreatic tumour progression. Additionally, two members of the annexin family (annexin A2 and A4) implicate a functional contribution of exocytotic and endocytotic pathways at that stage.

Adenocarcinoma↗

Determination of endocrine disrupting compounds in marine water by nanoliquid chromatography/direct-electron ionization mass spectrometry.

We present a new method for the determination of 29 endocrine-disrupting compounds in marine water. This method is based on a solid-phase extraction preconcentration technique, followed by a nanoscale liquid chromatography/direct-electron ionization (EI) mass spectrometric analysis. Direct-EI is a novel technique for the rapid conversion of a GC/MS into an efficient and reliable LC/MS for EI detection. The capability to acquire EI mass spectra of the analytes, and to operate in selected ion monitoring mode during real sample analyses, allows certain identification and precise quantification. In addition, this method is not influenced by the polarity of the analytes and does not require different detection modes (positive and negative) for identification with API techniques. Limits of detection of the method span from 0.4 to 118.7 ng.L(-1), corresponding to an instrumental detection limit of 0.005-1.260 ng. Linear regression and recovery experiment data, together with their standard deviations, are also presented. Marine water samples were collected along the middle-western Adriatic Coast (Italy), near the shore and at the mouth of rivers and canals.

Chromatography, Liquid↗