MANTIS: combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems.

We describe MANTIS (Monte carlo x-rAy electroN opTical Imaging Simulation), a tool for simulating imaging systems that tracks x-rays, electrons and optical photons in arbitrary materials and complex geometries. The x-ray and electron transport and involved physics models are from the PENELOPE package, and the optical transport and corresponding physics models are from DETECT-II and include Fresnel refraction and reflection at material boundaries, bulk absorption and scattering. Complex geometries can be handled with the aid of the geometry routines included in PENELOPE. When x-rays or electrons interact and deposit energy in the scintillator, the code generates a number of optical quanta according to a user-selected model for the conversion process. The optical photons are then tracked until they reach an absorption event, which in some cases contributes to the output signal, or escape from the geometry. We demonstrate the capabilities of this new tool with respect to the statistics of the optical signal detected and to the three-dimensional point-response functions corresponding to columnar phosphor screens.

Computer Simulation↗

Visual assessment of angular response in medical liquid crystal displays.

In spite of having non-Lambertian emission, displays based on liquid crystal technology are becoming popular for medical diagnostic work stations. For all liquid crystal displays (LCDs), the contrast performance varies with viewing direction. Accurate measurements of the angular distribution of light emission require expensive instrumentation and extensive expertise. We investigated the possibility of using a test pattern to visually assess the angular response performance of LCDs. We found that this procedure offers the end user of displays a simple, fast, and relatively consistent technique to verify that the viewing angle performance of the display device is within certain acceptable limits.

Computer Peripherals↗

Detectability decreases with off-normal viewing in medical liquid crystal displays.

RATIONALE AND OBJECTIVES: To quantify the reduction in detection performance of subtle signals at off-normal viewing directions in medical active-matrix liquid crystal displays (AMLCDs). MATERIALS AND METHODS: Fifty synthetic image pairs per viewing condition (a total of 350) were used in a two-alternative forced-choice experiment in which 11 trained observers viewed images at 0, 30, and 45 degrees from the display normal, along the diagonal axis of a 5 million pixel in-plane switching monochrome AMLCD. The images were generated using white-noise backgrounds. A Gaussian signal was added to the signal-present set with three different signal amplitudes (4, 8, and 12 gray levels in a 10-bit scale). RESULTS: The average percent correct achieved for a signal of 4 gray levels was 79.6 (95% confidence intervals based on reader and case variability: 71.6-86.9), 63.4 (CI 56.0-71.3), and 55.3 (CI 48.4-62.0), for 0, 30 and 45 degrees from the display normal, respectively. When the signal amplitude was increased by a factor of two, the performance was 76.9 and 57.0 for 30 and 45 degrees, respectively, and 95.3 and 85.3 when the amplitude was increased by a factor of three. The observers took on average about twice as long and as much as seven times as long to reach decisions in off-normal viewing. CONCLUSIONS: Off-normal viewing of diagnostic images in AMLCDs significantly reduces the detection of low-contrast abnormalities. Increased off-normal signal amplitudes were required to regain the detection performance measured for normal viewing. We observed this decrease in detection performance for off-normal viewing even when measured decision times were about twice as long as for normal viewing.

Computer Terminals↗

Anisotropic imaging performance in indirect x-ray imaging detectors.

We report on the variability in imaging system performance due to oblique x-ray incidence, and the associated transport of quanta (both x rays and optical photons) through the phosphor, in columnar indirect digital detectors. The analysis uses MANTIS, a combined x-ray, electron, and optical Monte Carlo transport code freely available. We describe the main features of the simulation method and provide some validation of the phosphor screen models considered in this work. We report x-ray and electron three-dimensional energy deposition distributions and point-response functions (PRFs), including optical spread in columnar phosphor screens of thickness 100 and 500 microm, for 19, 39, 59, and 79 keV monoenergetic x-ray beams incident at 0 degrees, 10 degrees, and 15 degrees. In addition, we present pulse-height spectra for the same phosphor thickness, x-ray energies, and angles of incidence. Our results suggest that the PRF due to the phosphor blur is highly nonsymmetrical, and that the resolution properties of a columnar screen in a tomographic, or tomosynthetic imaging system varies significantly with the angle of x-ray incidence. Moreover, we find that the noise due to the variability in the number of light photons detected per primary x-ray interaction, summarized in the information or Swank factor, is somewhat independent of thickness and incidence angle of the x-ray beam. Our results also suggest that the anisotropy in the PRF is not less in screens with absorptive backings, while the noise introduced by variations in the gain and optical transport is larger. Predictions from MANTIS, after additional validation, can provide the needed understanding of the extent of such variations, and eventually, lead to the incorporation of the changes in imaging performance with incidence angle into the reconstruction algorithms for volumetric x-ray imaging systems.

Anisotropy↗

Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report.

Digital imaging provides an effective means to electronically acquire, archive, distribute, and view medical images. Medical imaging display stations are an integral part of these operations. Therefore, it is vitally important to assure that electronic display devices do not compromise image quality and ultimately patient care. The AAPM Task Group 18 (TG18) recently published guidelines and acceptance criteria for acceptance testing and quality control of medical display devices. This paper is an executive summary of the TG18 report. TG18 guidelines include visual, quantitative, and advanced testing methodologies for primary and secondary class display devices. The characteristics, tested in conjunction with specially designed test patterns (i.e., TG18 patterns), include reflection, geometric distortion, luminance, the spatial and angular dependencies of luminance, resolution, noise, glare, chromaticity, and display artifacts. Geometric distortions are evaluated by linear measurements of the TG18-QC test pattern, which should render distortion coefficients less than 2%/5% for primary/secondary displays, respectively. Reflection measurements include specular and diffuse reflection coefficients from which the maximum allowable ambient lighting is determined such that contrast degradation due to display reflection remains below a 20% limit and the level of ambient luminance (Lamb) does not unduly compromise luminance ratio (LR) and contrast at low luminance levels. Luminance evaluation relies on visual assessment of low contrast features in the TG18-CT and TG18-MP test patterns, or quantitative measurements at 18 distinct luminance levels of the TG18-LN test patterns. The major acceptable criteria for primary/ secondary displays are maximum luminance of greater than 170/100 cd/m2, LR of greater than 250/100, and contrast conformance to that of the grayscale standard display function (GSDF) of better than 10%/20%, respectively. The angular response is tested to ascertain the viewing cone within which contrast conformance to the GSDF is better than 30%/60% and LR is greater than 175/70 for primary/secondary displays, or alternatively, within which the on-axis contrast thresholds of the TG18-CT test pattern remain discernible. The evaluation of luminance spatial uniformity at two distinct luminance levels across the display faceplate using TG18-UNL test patterns should yield nonuniformity coefficients smaller than 30%. The resolution evaluation includes the visual scoring of the CX test target in the TG18-QC or TG18-CX test patterns, which should yield scores greater than 4/6 for primary/secondary displays. Noise evaluation includes visual evaluation of the contrast threshold in the TG18-AFC test pattern, which should yield a minimum of 3/2 targets visible for primary/secondary displays. The guidelines also include methodologies for more quantitative resolution and noise measurements based on MTF and NPS analyses. The display glare test, based on the visibility of the low-contrast targets of the TG18-GV test pattern or the measurement of the glare ratio (GR), is expected to yield scores greater than 3/1 and GRs greater than 400/150 for primary/secondary displays. Chromaticity, measured across a display faceplate or between two display devices, is expected to render a u',v' color separation of less than 0.01 for primary displays. The report offers further descriptions of prior standardization efforts, current display technologies, testing prerequisites, streamlined procedures and timelines, and TG18 test patterns.

Computer Graphics↗

Comparison of conoscopic, telescopic, and goniometric methods for measuring angular emissions from medical liquid-crystal displays.

Although emissive displays exhibit a quasi-Lambertian emission, the anisotropy of the electro-optic effect that controls light transmission in liquid-crystal displays (LCDs) causes the pixel luminance to vary, sometimes strongly, with the viewing angle. These variations are not identical for all gray levels and can eventually cause gray-scale inversions. We compare methods currently used to measure angular luminance variations in the LCDs: the goniometric method, the telescopic method, and the conoscopic or Fourier-optics method. We show that, although they are the same at the high end of the gray scale, the results of the three methods differ significantly at lower gray levels. In some cases the measured luminance was as much as 38% higher for the conoscopic system, and 26% higher for the telescopic method, than the value obtained with the goniometric approach. This shift in the minimum luminance measurement translates directly into the contrast ratio, affecting the reporting of technical specifications of display systems.

Computer Peripherals↗

Effect of viewing angle on luminance and contrast for a five-million-pixel monochrome display and a nine-million-pixel color liquid crystal display.

Digital imaging systems used in radiology rely on electronic display devices to present images to human observers. Active-matrix liquid crystal displays (AMLCDs) continue to improve and are beginning to be considered for diagnostic image display. In spite of recent progress, AMLCDs are characterized by a change in luminance and contrast response with changes in viewing direction. In this article, we characterize high pixel density AMLCDs (a five-million-pixel monochrome display and a nine-million-pixel color display) in terms of the effect of viewing angle on their luminance and contrast response. We measured angular luminance profiles using a custom-made computer-controlled goniometric instrument and a conoscopic Fourier-optics instrument. We show the angular luminance response as a function of viewing angle, as well as the departure of the measured contrast from the desired response. Our findings indicate small differences between the five-million-pixel (5 MP) and the nine-million-pixel (9 MP) AMLCDs. The 9 MP shows lower variance in contrast with changes in viewing angle, whereas the 5 MP provides a slightly better GSDF compliance for off-normal viewing.

Contrast Sensitivity↗

Noise in flat-panel displays with subpixel structure.

Subpixel structures found in medical monochrome active-matrix liquid crystal displays (AMLCDs) affect noise estimates measured with conventional methods. In this work, we discuss methods that identify sources of noise and permit the comparison of luminance noise estimates across technologies independent of pixel design and device technology. We used a three-million pixel AMLCD with a pixel structure consisting of three color stripes, each in a two-domain, in-plane switching mode. Images of uniform fields displayed on the AMLCD were acquired using a low-noise, high-resolution CCD camera. The camera noise and flat-field response were characterized using a uniform light source constructed for this purpose. We show results in terms of spatial luminance noise and noise power spectrum for high-resolution images and for the same images processed with a pixel-aligned aperture. We find that the pixel-aligned aperture eliminates almost all the noise found in the high-resolution images, suggesting that most of the luminance noise in AMLCDs comes from the subpixel structure and less-than-100% aperture ratio, rather than from interpixel variations.

Computer Terminals↗

Lubberts effect in columnar phosphors.

Noise transfer in granular x-ray imaging phosphor screens is not proportional to the square of the magnitude of the signal transfer when the transfer properties are considered for the entire screen thickness, unless appropriately weighted at each depth of interaction. This property, known as the Lubberts effect, has not yet been studied in columnar structured screens because of a lack of a generalized description of the depth-dependent light transport. In this paper, we investigate the signal and noise transfer characteristics of columnar phosphors used in digital mammography detectors using DETECT-II, an optical Monte Carlo light transport simulation code. We first validate our choice of optical parameters for the description of granular and columnar screens using published normalized modulation transfer (MTF) experimental data. Our calculations of MTF match empirically measured MTFs for a granular film/screen analog system, and for an indirect x-ray digital imaging system with CsI:Tl screen representative of digital mammography systems. Using the depth-dependent spread functions and collection efficiencies, we calculate the signal and noise transfer functions and the Lubberts fraction, which is the ratio of the signal transfer function to the noise transfer function, for different screen thicknesses of granular and columnar phosphors. We find that the Lubberts fraction of a 85 microm granular screen model corresponding to a Gd2O2S:Tb screen is similar to the fraction for a 100 microm columnar CsI:Tl screen.

Computer Simulation↗

An energy- and depth-dependent model for x-ray imaging.

In this paper, we model an x-ray imaging system, paying special attention to the energy- and depth-dependent characteristics of the inputs and interactions: x rays are polychromatic, interaction depth and conversion to optical photons is energy-dependent, optical scattering and the collection efficiency depend on the depth of interaction. The model we construct is a random function of the point process that begins with the distribution of x rays incident on the phosphor and ends with optical photons being detected by the active area of detector pixels to form an image. We show how the point-process representation can be used to calculate the characteristic statistics of the model. We then simulate a Gd2O2S:Tb phosphor, estimate its characteristic statistics, and proceed with a signal-detection experiment to investigate the impact of the pixel fill factor on detecting spherical calcifications (the signal). The two extremes possible from this experiment are that SNR2 does not change with fill factor or changes in proportion to fill factor. In our results, the impact of fill factor is between these extremes, and depends on the diameter of the signal.

Calcinosis↗

Goniometric and conoscopic measurements of angular display contrast for one-, three-, five-, and nine-million-pixel medical liquid crystal displays.

Active-matrix liquid crystal displays (AMLCDs) have become the preferred choice for displaying digital diagnostic images because of their low cost of ownership, high contrast, and small footprint. However, the contrast and luminance of AMLCDs changes significantly with viewing direction. In this paper, we use a goniometric and a conoscopic method to measure angular contrast and luminance in one-, three-, five-, and nine-million-pixel medical AMLCDs. The viewing angle characteristics of the displays are compared by evaluating the compliance with the desired grayscale and recommended tolerance limits. Using the measured contrast responses, we determined the angle along each of the orthogonal and diagonal axes for which the luminance ratio drops to 0.5, 0.2, and 0.1 of the maximum ratio, seen at perpendicular viewing. The results show a reduction as large as 54% in available JND levels between the perpendicular and off-normal viewing directions. All of the display systems proved to have better angular response in the horizontal and vertical direction as compared to the diagonal directions, and none were able to satisfy a 20% contrast tolerance limit for any viewing direction lying in a cone at an angle of 45 degrees from the normal. Additionally, we show that the measured contrast can be significantly affected by the measurement method used to record the angular change in luminance.

Computer Terminals↗

Angular dependence of the luminance and contrast in medical monochrome liquid crystal displays.

Active-matrix liquid crystal displays (AMLCDs) are light-modulating devices that generate images by differentially transmitting a nearly uniform luminous field provided by a backlight. While emissive displays exhibit a quasi-Lambertian emission with almost constant contrast at off-normal viewing, the anisotropy of the electro-optic effect that controls light transmission in AMLCDs causes a pixel luminance that varies, sometimes strongly, with viewing angle. These variations are not identical for all gray levels and can eventually cause grayscale inversions. In this paper, we measured the luminance emission of a monochrome medical AMLCD, a medical cathode-ray tube monitor, and a color desktop AMLCD, using a collimated photopic probe positioned on a manual rotation arm, and a research radiometer with automatic readout. The probe measures luminance with a small acceptance angle and provides optical shielding from emissions at other viewing directions that contaminate the readings. We obtained luminance response curves versus angle in the vertical, horizontal and at 45 degrees diagonal directions. The display systems were calibrated to reflect the DICOM Part 3.14 standard grayscale display function (GDF) when measured using the manufacturer's probe and software tools. We analyzed the measurements at different viewing directions with respect to their departure from the GDF by computing the normalized contrast (deltaL/L) as a function of the DICOM just-noticeable difference index. Although cathode-ray tubes are known to be quasi-Lambertian emitters, the luminance at normal viewing is higher than the luminance observed at large angles. This decrease in luminance is however proportionally similar for all gray levels, resulting in a relatively flat contrast response for all angles. In addition to being more pronounced, the angular variation in AMLCDs does not follow the same profile at different intensities with the subsequent variation in the achieved display contrast. The changes due to off-normal viewing are substantial at large angles in the horizontal and vertical directions, and much worse in the diagonal viewing directions.

Anisotropy↗

Modeling the bidirectional reflectance of emissive displays.

The reflection properties of a display device influence the available contrast and affect the perception of subtle detail. The display reflection characteristics of flat-panel displays (FPDs) are appropriately described by a six-dimensional bidirectional reflectance distribution function (BRDF). I describe a Monte Carlo method for modeling the bidirectional reflectance of multilayer emissive structures used in electronic display devices. I estimate the complete BRDF using a one-dimensional angular distribution function of the luminance. I apply the method to model typical high-performance cathode-ray tube and FPD structures. I find that, for the BRDF signatures of cathode-ray tubes characterized by a specular and a quasi-Lambertian components, the estimated values for the specular and diffuse reflection coefficients agree well with low-resolution experimental measurements conducted with a rotation arm and a collimated probe. I show that emissive FPDs with thin-film organic layers on reflective substrates can exhibit a predominant specular peak broadened by short-range light scattering.

Data Display↗

AAPM/RSNA tutorial on equipment selection: PACS equipment overview: general guidelines for purchasing and acceptance testing of PACS equipment.

A picture archiving and communication system (PACS) is a comprehensive computer system that is responsible for the electronic storage and distribution of medical images in the medical enterprise. The system is highly integrated with digital acquisition and display devices and is often related closely to other medical information systems, such as the radiology information system or hospital information system. In the past few years, there has been continuous growth in clinical implementation of PACS to reduce costs and improve patient care, a trend that is expected to continue. However, a PACS is complex and costly to acquire, replace, maintain, and repair. To select a system that best meets their requirements, purchasers of PACS equipment need to be aware of the key characteristics and differing features of the various products. After the PACS has been installed, the user should perform technical and clinical acceptance testing to ensure that the system meets expectations.

Data Display↗

AAPM/RSNA tutorial on equipment selection: PACS equipment overview: display systems.

Display systems are key components of the digital radiology department. Current display systems for medical imaging are based on cathode-ray tubes (CRTs) or active-matrix liquid crystal displays (AMLCDs). The CRT is a cathodoluminescent display: Light is generated by exciting a luminescent material with energetic electrons. AMLCDs are light-modulating devices that form the image in the screen by controlling the transparency of individual display pixels. Many image quality aspects of CRTs are determined by the way the pixel luminance is generated in the cathodoluminescent screen. The resolution properties of AMLCDs are much better than those of CRTs. In CRT devices, phosphor granularity and raster scanning patterns are the main components of spatial noise. In AMLCDs, the most notable feature of the noise characteristic is the subpixel structure of complex pixel designs used in medical displays. The small-spot contrast of CRTs is dominated mainly by veiling glare and reflections of ambient illumination. In addition to display reflectance, the contrast of medical AMLCDs is affected by crosstalk and by variations of the luminance at off-normal viewing angles.

Data Display↗