PubMed Health⌕ Search

Biomedical subjects

B S Edwards

Publications and source records attributed to B S Edwards.

At least 19 recordsLinked to original sources

Eosinophil traffic in the circulation following allergen challenge.

BACKGROUND: Eosinophils contribute to the pathogenesis of asthma and localize to the lung after allergen exposure by uncertain mechanisms. METHODS: We used intrabronchial instillation of allergen to model the interaction between inhaled allergen and the lung. We measured the number of peripheral blood leukocytes and the expression of VLA-4 (CD49d), Mac-1 (CD11b) and PSGL-1 (CD162) up to 4 h after instillation of allergen into a bronchus of eight atopic asthmatics. For controls, we instilled normal saline into a subset of the asthmatic subjects, and allergen into nonatopic, nonasthmatic subjects. RESULTS: There were changes of total leukocyte number, number of polymorphonuclear leukocytes, lymphocytes, monocytes and eosinophils in all three groups (atopic asthmatics instilled with allergen, atopic asthmatics instilled with saline, nonatopic nonasthmatic subjects instilled with allergen), which were likely related to bronchoscopy. However, the decrease of eosinophils was significant only in the atopic asthmatics instilled with allergen. The remaining eosinophils in the allergen challenged asthmatics were not activated as defined by cell density or change of expression of VLA-4, Mac-1 and PSGL-1. CONCLUSIONS: While eosinophils rapidly and specifically leave the circulation after allergen challenge of atopic asthmatics, the remaining circulating eosinophils are not activated.

Administration, Inhalation↗

High throughput screening of G-protein coupled receptors via flow cytometry.

The molecular assemblies of signal transduction components, for example kinases and their target proteins or receptor-ligand complexes and intracellular signaling molecules, are critical for biological functions in cells. To better understand the interactions of these molecular assemblies and to screen for new pharmaceutics that could control and modulate these types of interactions, we have focused on developing high throughput approaches for the analysis of G-protein coupled receptors via flow cytometry. Flow cytometry offers a number of advantages including real-time collection of multicomponent data, and together with improvements in sample handling, the high throughput sampling rate is up to 100 samples per minute. For our targets, assemblies of solubilized GPCRs, a screening platform of a dextran bead has proven to be flexible, allowing different surface chemistries on the beads. The bead can be either ligand-labeled or have epitope-linked proteins attached to the bead surface, enabling several molecular assemblies to be constructed and analyzed. A major improvement with this system is that for screening ligands for GPCRs the underlying mechanism of action for these compounds can be investigated and incorporated into the definition of a 'hit'. Our current screening system is capable of simultaneously distinguishing GPCR agonists and antagonists.

Animals↗

Mixing small volumes for continuous high-throughput flow cytometry: performance of a mixing Y and peristaltic sample delivery.

BACKGROUND: Online mixing for continuous high-throughput flow cytometry has not been previously described. A simple, general high-throughput method for mixing and delivery of submicroliter volumes in laminar flow at low Reynolds numbers would be widely useful. MATERIALS AND METHODS: We describe a micromixing approach that is compatible with commercial autosamplers, flow cytometry, and other detection schemes that require mixing of components that have been introduced into laminar flow. The scheme is based on a previous approach to high-throughput flow cytometry (HyperCyt, Kuckuck et al.: Cytometry 44:83-90, 2001). We showed that samples from multiwell plates that have been picked up by an autosampler can be separated during delivery by the small air bubbles introduced during the transit of the autosampler probe from well to well. Here, a particle sample flowing continuously is brought together in a Y with reagent samples from wells, which have been separated by bubbles. RESULTS: In the effluent stream, the particles and reagents are mixed, most likely as a result of peristaltic action, and reagents from individual wells can be resolved. The sample volumes that can be mixed with this technology are submicroliter in volume, and samples can be mixed at rates up to at least 100/samples per minute. With the current device, carryover between samples can be eliminated if the mixing system is flushed with several volumes of buffer. The anticipated throughput for screening is expected to be at least 20 samples per minute. CONCLUSIONS: The high-throughput approach and peristaltic mixing in HyperCytTM serve to integrate autosamplers with submicroliter detection volumes for analysis in flow cytometry or in microfluidic channels.

Avidin↗

Performance of in-line microfluidic mixers in laminar flow for high-throughput flow cytometry.

We describe a micromixing approach that is compatible with commercial autosamplers, flow cytometry, and other detection schemes that require the mixing of components that have been introduced into laminarflow. The scheme is based on high-throughput flow cytometry (HyperCyt) where samples from multi-well plates that have been picked up by an autosampler can be separated during delivery by the small air bubbles introduced during the transit of the autosampler probe from well to well. Here, either cell or particle samplesflowing continuously and driven by a syringe are brought together in a Y with reagent samples from wells driven by a peristaltic pump. The mixing is driven by a magnetic microstirrer contained within the sample line. The mixing is assessed using fluorescence of both cell calcium responses and bead-based fluorescence unquenching. In the analysis stream, the particles and reagents are mixed with eithera "wire" or "bar". The bar is more efficient than the wire, and the efficiency of either depends on the spinning action. The high-throughput approach and mixing in HyperCyt integrate autosamplers with submicroliter detection volumes for analysis in flow cytometry or in microfluidic channels.

Equipment Design↗

Real time analysis of the affinity regulation of alpha 4-integrin. The physiologically activated receptor is intermediate in affinity between resting and Mn(2+) or antibody activation.

This work examines the affinity of alpha(4)beta(1)-integrin and whether affinity regulation by G protein-coupled receptor (GPCR) and chemokines receptors is compatible with cell adhesion mediated between alpha(4)-integrin and vascular cell adhesion molecule-1. We used flow cytometry to examine the binding of a fluorescent derivative of an LDV peptide (Chen, L. L., Whitty, A., Lobb, R. R., Adams, S. P., and Pepinsky, R. B. (1999) J. Biol. Chem. 274, 13167-13175) to several cell lines and leukocytes with alpha(4)-integrin ranging from about 2,000 to 100,000 sites/cell. The results support the idea that alpha(4)-integrins exhibit multiple affinities and that affinity changes are regulated by the dissociation rate and conformation. The affinity varies by 3 orders of magnitude with the affinity induced by binding mAb TS2/16 plus Mn(2+) > Mn(2+) ' TS2/16 > activation because of occupancy of GPCR or chemokines receptor > resting receptors. A significant fraction of the receptors respond to the activating process. The change in alpha(4)-integrin affinity and the corresponding change in off rates mediated by GPCR receptor activation are rapid and transient, and their duration depends on GPCR desensitization. The affinity changes mediated by IgE receptor or interleukin-5 receptor persist longer. It appears that the physiologically active state of the alpha(4)-integrin, determined by inside-out signaling, has similar affinity in several cell types.

Antibodies, Monoclonal↗

High throughput flow cytometry.

BACKGROUND: Conventional flow cytometry does not allow the rapid analysis of multiple samples. This has limited its uses in drug discovery, for which the standard for throughput is 100,000 samples per day. METHODS: We describe a simple method in which commercial peristaltic tubing is connected from a commercial autosampler to a flow cytometer. The samples are delivered via a peristaltic pump from source wells in a multiwell plate. The samples are separated by air bubbles. RESULTS: Throughput rates approach the limit of the autosampler (up to 100 wells per minute). Using optimal tubing and flow rates, particles remain within appropriate light scatter and fluorescence gates. The carryover between wells is typically less than 5% without and 1% with a wash step. The volumes of sample delivered are in the microliter scale. The approach has been validated with instruments from three manufacturers. CONCLUSIONS: Flow cytometry has potential throughput of 100,000 samples or more per day starting with the method described. The method is currently best suited to end-point assays. However, combined with high-speed sorting and single- cell assays, the number of assays could approach 1 billion per day.

Flow Cytometry↗

Plug flow cytometry extends analytical capabilities in cell adhesion and receptor pharmacology.

BACKGROUND: Plug flow cytometry is a recently developed system for the automated delivery of multiple small boluses or "plugs" of cells or particles to the flow cytometer for analysis. Important system features are that sample plugs are of precisely defined volume and that the sample vessel need not be pressurized. We describe how these features enable direct cell concentration determinations and novel ways to integrate flow cytometers with other analytical instruments. METHODS: Adhesion assays employed human polymorphonuclear neutrophils (PMNs) loaded with Fura Red and Chinese hamster ovary (CHO) cells cotransfected with genes for green fluorescent protein (GFP) and human P-selectin. U937 cells expressing the human 7-transmembrane formyl peptide receptor were loaded with the fluorescent probe indo-1 for intracellular ionized calcium determinations. A computer-controlled syringe or peristaltic pump loaded the sample into a sample loop of the plug flow coupler, a reciprocating eight-port valve. When the valve position was switched, the plug of sample in the sample loop was transported to the flow cytometer by a pressure-driven fluid line. RESULTS: In stirred mixtures of PMNs and CHO cells, we used plug flow cytometry to directly quantify changes in concentrations of nonadherent singlet PMNs. This approach enabled accurate quantification of adherent PMNs in multicell aggregates. We constructed a novel plug flow interface between the flow cytometer and a cone-plate viscometer to enable real-time flow cytometric analysis of cell-cell adhesion under conditions of uniform shear. The High Throughput Pharmacology System (HTPS) is an instrument used for automated programming of complex pharmacological cell treatment protocols. It was interfaced via the plug flow coupling device to enable rapid (< 5 min) flow cytometric characterization of the intracellular calcium dose-response profile of U937 cells to formyl peptide. CONCLUSIONS: By facilitating the coupling of flow cytometers to other fluidics-based analytical instruments, plug flow cytometry has extended analytical capabilities in cell adhesion and pharmacological characterization of receptor-ligand interactions.

Animals↗

Fatal disseminated aspergillosis following sequential heart and stem cell transplantation for systemic amyloidosis.

Infectious complications are a major cause of morbidity and mortality in transplant recipients. We describe a case of fatal disseminated aspergillosis immediately following autologous peripheral stem cell reconstitution in a patient who had undergone orthotopic heart transplantation for systemic amyloidosis. The case described suggests that the infectious risks in patients undergoing these sequential procedures may be distinct from those occurring in patients undergoing either procedure independently. Potential prophylactic and therapeutic interventions are discussed. Since this experimental and evolving approach for the management of systemic amyloidosis is potentially applicable to a limited number of patients, multicenter collaboration may be needed to further define the infectious risks in this unique subset of transplant recipients.

Adult↗

HTPS flow cytometry: a novel platform for automated high throughput drug discovery and characterization.

The flow cytometer is unique among biomedical analysis instruments because it makes simultaneous and multiple optical measurements on individual cells or particles at high rates. High throughput flow cytometry represents a potentially important multifactorial approach for screening large combinatorial libraries of compounds. Limiting this approach has been the availability of instrumentation and methods in flow cytometry for automated sample handling on the scale required for drug discovery applications. Here, we describe an automated system in which a novel patented fluidics-based pharmacology platform, the HTPS (High Throughput Pharmacological System), is coupled to a flow cytometer using a recently described plug flow-coupling valve technology. Individual samples are aspirated sequentially from microplate wells and delivered to a flow cytometer for rapid multiparametric analysis. For primary screening to detect and quantify cell fluorescence in endpoint assays, a high-speed no-wash protocol enabled processing of 9-10 cell samples/min from 96-well microplates. In an alternate primary screening format, soluble receptor ligands were sampled from microplate wells at rates of 3-4 samples/minute and successfully assessed for the ability to elicit intracellular calcium responses. Experiments with fluorescent beads validated the accurate automated production by the HTPS of exponential and linear gradients of soluble compounds. This feature enabled rapid (2- to 3-min) characterization of the intracellular calcium dose response of myeloid cells to formyl peptide as well as the quantitative relationship between formyl peptide receptor occupancy and cell response. HTPS flow cytometry thus represents a powerful high throughput multifactorial approach to increase the efficiency with which novel bioresponse-modifying drugs may be identified and characterized.

Automation↗

Expression of P-selectin at low site density promotes selective attachment of eosinophils over neutrophils.

The selective interaction of neutrophils with E-selectin and eosinophils with P-selectin has been previously reported, but the relevance of selectin site density and fluid shear has not been studied in detail. We have developed a new approach to examine these interactions in cell suspensions that integrates an on-line cone-plate viscometer with a flow cytometer. We find that eosinophils and neutrophils both use P-selectin glycoprotein ligand-1 to form stable conjugates with P-selectin Chinese hamster ovary cell transfectants, with a preferential adhesion of eosinophils. Further, the difference in cell adhesion between neutrophils and eosinophils is magnified at P-selectin expression levels below approximately 20 sites/microm2, a range likely to be relevant to endothelial cell expression levels in conditions associated with eosinophilia. The unique behavior is retained over shear rates ranging from 100 to 1500/s but is magnified at low shear. Results from parallel-plate flow chamber assays suggest that preferential eosinophil adhesion reflects an enhanced efficiency of initial PSGL-1 bond formation with P-selectin rather than a unique ability of eosinophils to mediate rolling interactions of longer duration on low-density P-selectin substrates. These differences may account in part for the increase in eosinophil accumulation in allergic diseases.

Animals↗

Sulfhydryl regulation of L-selectin shedding: phenylarsine oxide promotes activation-independent L-selectin shedding from leukocytes.

The L-selectin adhesion molecule mediates leukocyte recruitment to inflammatory sites and lymphocyte trafficking through the peripheral lymph nodes. In response to leukocyte activation, L-selectin is proteolytically released from the cell surface, disabling leukocytes from the subsequent L-selectin-dependent interactions. We have found that L-selectin shedding is sensitive to sulfhydryl chemistry; it is promoted by thiol-oxidizing or -blocking reagents and inhibited by reducing reagents. Phenylarsine oxide (PAO), a trivalent arsenical that interacts with vicinal dithiols, is most potent in inducing rapid shedding of L-selectin from isolated neutrophils, eosinophils, and lymphocytes as well as from neutrophils in whole blood. PAO does not cause cell activation, nor does it interfere with integrin function or alter the expression of several other cell surface molecules at the low concentrations that induce L-selectin shedding. PAO is not required to enter the cell to induce L-selectin shedding. TAPI-2 ((N-(D,L-[2-(hydroxyaminocarbonyl)-methyl]-4-methylpentanoyl)-L-3-(tert-butyl)-alanyl-l -alanine, 2-aminoethyl amide), which has previously been shown to inhibit the activation-dependent L-selectin shedding, is also capable of inhibiting PAO-induced L-selectin shedding. We hypothesize that PAO-induced L-selectin shedding involves a regulatory molecule, such as protein disulfide isomerase (PDI), an enzyme that plays a role in the formation and rearrangement of disulfide bonds, contains PAO-binding, vicinal dithiol-active sites, and is expressed on the neutrophil surface. Cell surface expression of PDI, L-selectin shedding induced by PDI-blocking Abs and by bacitracin, a known inhibitor of PDI activity, and direct binding of PDI to PAO, provide supporting evidence for this hypothesis.

Arsenicals↗

Analysis of free intracellular calcium by flow cytometry: multiparameter and pharmacologic applications.

Flow cytometry offers numerous advantages over traditional techniques for measuring intracellular Ca(2+) in lymphoid and nonlymphoid cells. In particular, the heterogeneity of cell responses can be defined by flow cytometry, and multiparameter analyses permit the determination of intracellular Ca(2+) in surface-marker-defined target cells as well as correlation of changes in Ca(2+) with other biochemical markers, including ligand binding. This article presents several established methods for measuring intracellular Ca(2+) by flow cytometry in lymphoid and nonlymphoid cells. Examples are provided for determination of Ca(2+) in human peripheral blood leukocytes and two human epithelial cell lines grown in monolayer. In addition, applications are reviewed or presented for correlating changes in intracellular Ca(2+) with other cell parameters, including cell cycle analysis, changes in cell membrane integrity, and the induction of apoptosis markers. Finally, a number of novel sample handling capabilities useful for performing kinetic analyses of Ca(2+) changes by flow cytometry are now available and one application is presented which is finding utility in pharmacologic studies.

Aniline Compounds↗

Heart transplantation for radiation-associated end-stage heart failure.

Radiation-induced heart disease is an increasingly recognized late sequela of mediastinal radiation therapy for malignant neoplasms. We report four cases of heart transplantation for end-stage heart failure induced by mediastinal radiation therapy. Short-term and intermediate-term results are excellent with all four patients currently surviving a mean of 48 months after transplantation. Neither a second malignancy nor recurrence of the primary malignancy has been observed to date. The early results of heart transplantation for end-stage, radiation-induced heart disease are encouraging.

Adult↗

Intracardiac ectopic thyroid.

Intracardiac ectopic thyroid is a rare lesion. We present a case of successful excision of thyroid tissue obstructing the right ventricular outflow tract and provide a literature review. In all cases reported to date, the ectopic tissue arose from the ventricular septum and extended to the outflow tract.

Aged↗

Plug flow cytometry: An automated coupling device for rapid sequential flow cytometric sample analysis.

BACKGROUND: The tools for high throughput flow cytometry have been limited in part because of the requirement that the samples must flow under pressure. We describe a simple system for sampling repetitively from an open vessel. METHODS: Under computer control, the sample is loaded into a sample loop in a reciprocating eight-way valve by the action of a syringe. When the valve position is switched, the plug of sample in the sample loop is transported to the flow cytometer by a pressure-driven fluid line. By coupling the plug-forming capability to a second multi-port valve, samples can be delivered sequentially from separate vessels. RESULTS: The valve is able to deliver samples at rates ranging up to about 9 samples per minute. Each plug of sample has uniform delivery characteristics with a reproducible coefficient of variation (CV). Even at the highest sampling rate, carryover between samples is limited. CONCLUSIONS: Plug-flow flow cytometry has the potential to automate the delivery of small samples from unpressurized sources at rates compatible with many screening and assay applications.

Animals↗

Endothelin-1 modulates intrahepatic resistance in a rat model of noncirrhotic portal hypertension.

Factors that increase resistance to blood flow through the hepatic sinusoids when portal hypertension occurs in the absence of significant hepatic fibrosis are not completely understood. Experiments were designed to test the hypothesis that endothelin-1 (ET-1) is one of the humoral factors that increases sinusoidal vascular resistance in a bile duct- ligated noncirrhotic portal hypertensive (BDL) rat. The effect of ET-1 and nitric oxide (NO) on contractility of rings of portal vein taken from BDL rats was tested. The effect of ET-1 and NO on intrahepatic resistance in an isolated perfused liver was studied, and localization of ET-1 in the liver was identified by immunohistochemistry. Portal vein rings in BDL rats showed increased maximal tension in response to ET-1, as well as a shift of the dose-response curve to the left as compared with sham-operated animals. Removal of the endothelium further increased contractility. In isolated perfused liver studies, ET-1 increased portal resistance in both sham operated and BDL rats. The endothelin Type A receptor antagonist BQ 123 lowered the high portal resistance in BDL rats to levels comparable with sham operated animals. Infusion of L-arginine lowered resistance to a much smaller extent. In livers from BDL rats, ET-1 was localized in periportal and pericentral hepatocytes and hepatic sinusoidal cells. We conclude that in a BDL model of portal hypertension where distortion of hepatic architecture by fibrosis is minimal, increased resistance to portal blood flow may be mediated by ET-1.

Animals↗