PubMed Health⌕ Search

Biomedical subjects

Daniel J Ehrlich

Publications and source records attributed to Daniel J Ehrlich.

6 recordsLinked to original sources

Solid-support sample loading for DNA sequencing.

We present a new method for simplified low-quantity DNA loading onto microelectrophoresis devices. The method is based on combined solid-phase extraction, purification, and transport of DNA reversibly bound on paramagnetic microspheres. DNA is adsorbed onto the microspheres, captured with a magnetized permalloy wire, and then directly injected as a highly focused sample plug into the separation channel. This method circumvents both the minimum volume requirement of pipettors (since only solid beads are transported) and the timing complications of double-T microfluidic injection. Injections from Sanger samples of <100 pg total suspended weight match the signal strength of our previous conventional injections at >10-times the starting DNA sample. Sequencing traces show a resolution that matches or exceeds double-T injections. A kinetic model reproduces the time-dependence of the injection signals and proves that total nonidealities in the method produce injection-broadened plugs of approximately 1-s duration. The method should be broadly extendable to DNA and protein separations in both microdevice and capillary electrophoresis.

Base Sequence↗

Numerical model for DNA loading in microdevices: stacking and autogating effects.

Many electrophoresis-based DNA sequencing and genotyping microdevices rely on field-driven effects to load and preconcentrate the sample. A quantitative model is developed for a broad class of electrophoresis-based microfabricated sample injectors. Quantitative predictions of DNA preconcentration are compared with experimental data and are shown to qualitatively reproduce the detailed time-evolving sample distribution in the injector. The model provides practical guidance on device and protocol design, in order to optimize this critical aspect of microfluidic devices.

DNA↗

Microdevice DNA forensics by the simple tandem repeat method.

We review recent experiments on DNA forensics by the simple tandem repeat (STR) method using a 16-lane micromachined device as the active separation element. Separations by linear polyacrylamide matrices show very high data quality metrics when evaluated with statistically significant data sets. Full 16-locus multiplexes are verified on the multilane system. Multi-donor mixed samples are studied in the context of the limits of the laser-induced fluorescence detector and data-reduction software. The microdevice appears to be posed to outperform current capillary arrays in terms of stability and, through specialized sample loading, in the interpretation of complex mixtures.

DNA↗

A 768-lane microfabricated system for high-throughput DNA sequencing.

A 768-lane DNA sequencing system based on microfluidic plates has been designed as a near-term successor to 96-lane capillary arrays. Electrophoretic separations are implemented for the first time in large-format (25 cm x 50 cm) microdevices, with the objective of proving realistic read length, parallelism, and the scaled sample requirements for long-read de novo sequencing. Two 384-lane plates are alternatively cycled between electrophoresis and regeneration via a robotic pipettor. A total of greater than 172000 bases, 99% accuracy (corresponding to quality score 20) is achieved for each iteration of a 384 lane plate. At current operating conditions, this implies a system throughput exceeding 4 megabases of raw sequence (Phred 20) per day on the new platform. Standard operation is at "1/32x" Sanger chemistry, equal to typical genome center operation on mature capillary array machines, and a 16-fold improvement in scaling relative to previous microfabricated devices. Experiments provide evidence that sample concentration can be further reduced to 1/256x Sanger chemistry in the microdevice. Life-testing indicates a usable life of >150 hours (more than 50 runs) for the 384 lane plates. The combined advances, particularly those in read length and sample requirement, directly address the cost model requirements for adaptation of the new technology as the next step beyond capillary array instruments.

DNA↗

Enhanced detection sensitivity using a novel solid-phase incorporated affinity fluorescent protein biosensor.

We engineered green fluorescent protein (GFP) into affinity fluorescent proteins (aFPs) biosensors. The aFPs detect protein-protein interactions by enhanced fluorescence intensity. In a proof of principle demonstration, aFPs containing haemagglutinin (HA) tag bind specifically to the anti-HA antibody. The sensitivity and specificity is enhanced 28-fold by incorporation of aFPs into solid-phase surface.

Antibodies, Monoclonal↗

Thirty-cycle temperature optimization of a closed-cycle capillary PCR machine.

The performance of a novel thermal cycler has been characterized in a 30-cycle PCR. The device consists of a microcapillary equipped with bidirectional pressure-driven flow and in situ optical position sensors. A 1-microL droplet of reaction mixture moves between three heat zones in a 1-mm i.d., oil-filled capillary using a multi-element scattered light detector and active feedback. The design permits time and number of cycles to be changed without hardware modification, unlike other flow-in-capillary PCR systems. Temperature optimization has been performed on the three PCR heat steps. The optimal denaturation temperature is 94 degrees C-96 degrees C, which is identical to commercial machines. The optimal extension temperature of 62 degrees C-66 degrees C is lower than reported for Taq DNA polymerase (70 degrees C-80 degrees C) because of the high enzyme concentration and/or the absence of detergent in the PCR mixture. The optimal annealing temperature seems to be the same as the optimal extension temperature. This is because extension occurs when the sample is inside of the annealing heat zone. Annealing takes place as the sample travels between heat zones. Device speed (23 minfor 30 cycles without time optimization) is competitive with other rapid PCR designs for efficiencies comparable to a commercial machine.

Bacteriophage lambda↗