PubMed Health⌕ Search

Biomedical subjects

G Grimandi

Publications and source records attributed to G Grimandi.

10 recordsLinked to original sources

Neointimal hyperplasia after stenting in a human mammary artery organ culture.

Although the use of stents has limited the incidence of restenosis, in-stent restenosis remains an important problem. In-stent restenosis is the result of a healing process that induced neointimal hyperplasia through mechanisms that are still not understood. The aim of this study was to analyze the histological consequences of the healing process following stent implantation. Internal mammary arteries from atheroslerotic patients undergoing coronary artery bypass surgery were stented and maintained in culture for 0-28 days. Stent implantation after predilatation induced an extensive loss of endothelial cells whereas direct stenting preserved endothelium between the struts. Morphometric analysis shows that stent placement induced neointimal thickening. Smooth muscle alpha-actin labeling indicates that neo-intimal formation was mainly due to proliferation and migration of smooth muscle cells. Smooth muscle cell proliferation, assessed by MIB-1 staining, was maximal at day 14 after stent insertion. Human mammary artery organ culture thus provides valuable information on histological consequences of stent implantation with or without predilatation regarding endothelial cell disappearance and neointimal hyperplasia. These data also demonstrate that neointimal thickening induced by stent implantation comprises an intrinsic component resulting from the vessel wall response to stent insertion and suggest that blood factors could play an amplifying but not necessary role.

Cell Division↗

Vancomycin encapsulation in biodegradable poly(epsilon-caprolactone) microparticles for bone implantation. Influence of the formulation process on size, drug loading, in vitro release and cytocompatibility.

Vancomycin encapsulation in biodegradable poly(epsilon-caprolactone) microparticles (200 microm mean diameter) was most efficient with a simple emulsion technique that dispersed 122.5 mg/g of polymer. Scanning electron micrographs showed smooth or pitted particles. Dissolution studies were correlated with microparticle morphology, indicating higher release with pitted particles when vancomycin was encapsulated in a dissolved state. The cytocompatibility of these poly(epsilon-caprolactone) microparticles was demonstrated by a direct contact cytotoxic assay. This material can be considered as an efficient drug delivery system for bone implantation.

Absorbable Implants↗

A new injectable bone substitute combining poly(epsilon-caprolactone) microparticles with biphasic calcium phosphate granules.

Previous studies have shown the effectiveness of an injectable bone substitute (IBS) composed of biphasic calcium phosphate in 2% hydroxypropyl methylcellulose gel (50/50 w/w). A therapeutic agent in the form of a drug can be added to the biomaterial by encapsulation into microparticles to protect the active agent, control its release and preserve the material rheological properties. Poly(epsilon-caprolactone) was used in this study because of its biocompatibility and resorbability, as tested in orthopaedic implants and surgical sutures. Particles (80-200 microm) were manufactured by a solvent evaporation-extraction process (1 g of polymer, 11-15 ml methylene chloride, with a stirring speed of 400-600 rpm) and introduced into the IBS in a 5-50% (V/V) range. Injectability was evaluated by texture analysis. With less than 45% of particles, the material had rheological properties similar to those of the reference IBS, whereas injectability decreased markedly with more than 45% of particles. A preliminary in vitro release study showed that this type of triphasic IBS could be efficient for drug delivery systems with osteoconduction properties.

Anti-Bacterial Agents↗

Injectable bone substitute using a hydrophilic polymer.

We studied a new injectable biomaterial for bone and dental surgery consisting of a hydrophilic polymer as matrix and bioactive calcium phosphate (CaP) ceramics as fillers. This material is composed of complex fluids whose flow is determined by the laws of rheology. We investigated the macromolecular effects on this composite in a tube. The stability of the polymer and the mixture is essential to the production of a ready-to-use injectable biomaterial. These flow properties are necessary to obtain CaP bioactivity in a dental canal or bone defect during percutaneous surgery. Macromolecules provide spaces between CaP ceramic granules and facilitate the role of the biological agents of bone substitution.

Animals↗

A new injectable calcium phosphate biomaterial for immediate bone filling of extraction sockets: a preliminary study in dogs.

BACKGROUND: Many different bone substitutes, such as autografts, allografts or synthetic biomaterials have been proposed to restore alveolar bone loss and support efficient placement of dental implants. This experimental study evaluated the osteoconductive properties of an injectable bone substitute (IBS) composed of a polymeric carrier and a calcium phosphate mineral phase, used to fill mandibular and maxillary canine extraction sockets. METHODS: The polymer was a cellulose derivative (methyl-hydroxy-propyl-cellulose, MHPC), and the mineral phase consisted of granules of biphasic calcium phosphate (BCP) ceramics 200 to 500 microm in diameter. Mandibular and maxillary premolars extracted from 3 dogs (a total of 60 extraction sites) were immediately treated with the IBS or left unfilled as control sites. Animals were sacrificed 3 months after implantation and all extraction sockets were prepared for histological evaluation. RESULTS: Qualitative histological studies showed that the IBS was able to support the extensive apposition of well-mineralized newly formed lamellar bone over the entire socket surface and appeared to prevent alveolar ridge bone loss in treated extraction sites. Quantitative evaluation showed that the amount of newly formed bone was significantly higher in mandibular than maxillary extraction sockets for both treated and control sites. CONCLUSIONS: An injectable bone substitute composed of a polymeric carrier and calcium phosphate was effective in enhancing the bone fill of extraction sockets. This approach may prove promising for periodontal lesions. The material expressed osteoconductive capacities, and the biological properties of the mineral phase were conserved.

Animals↗

In vitro influence of apatite-granule-specific area on human growth hormone loading and release.

Although calcium phosphate biomaterials often are used as drug delivery systems (DDS) at bone sites, the conditions affecting the loading of the therapeutic agent (TA) have not been well documented. A human growth hormone (hGH) adsorption method was used in this study to investigate the influence of the formulated apatite (AP)-specific area on loading and release. AP powders were formulated with a 200-500 microm granulometry and various specific areas. Two milligrams of hGH in solution were deposited for 24 h at 37 degrees C on 100 mg of AP with different specific areas. The amount of hGH loaded was determined by immunoradiometric assay (IRMA) and eluted stain bioassay (ESTA) using Nb2 lymphoma rat cells. Although loading was not greatly influenced by a specific area between 3 and 25 m2/g, dependency was noted for higher specific areas. Human GH release was measured by IRMA and ESTA over a 33-day period, with half-time release between 25 and 79 h. Comparison of IRMA and ESTA measurements for the hGH amounts loaded showed that hGH biologic activity was conserved. Results indicate that it is feasible to control the quantity of TA loading on AP by modifying specific areas for in vivo applications.

Animals↗

In vitro evaluation of a new injectable calcium phosphate material.

The purpose of this study was to develop an injectable bone substitute (IBS) for percutaneous orthopedic surgery. The multiphasic material used was composed of a 2% aqueous solution of methylhydroxypropylcellulose (MHPC) and biphasic calcium phosphate (BCP, 60% hydroxyapatite and 40% beta-tricalcium phosphate) in which MHPC served as the carrier for 80-200 microm of BCP granules. The best BCP/polymer ratio was determined by the rheological properties and higher BCP content of the material. Steam sterilization was more effective than gamma irradiation in maintaining the stability of the mixture and conserving its physiochemical and mechanical properties. The in vitro biocompatibility of the composite was checked by direct-contact cytotoxicity and cell-proliferation assays. A preliminary in vivo test was performed in the rabbit using intraosseous implantations in the femoral epiphysis. Histological analysis was done after 1, 2, 4, and 10 weeks. Bone ingrowth into the IBS, in close association with BCP granules, was observed after 1 week and increased regularly from the surface inward at 2, 4, and 10 weeks. At the same time, smaller BCP granules (less than 80 microns in diameter) were degraded and resorbed. This injectable biomaterial proved suitable for cavity filling. The water solubility and viscosity of the polymer allow cells to recolonize, with in situ bonding of the mineral phase.

Animals↗

Apatite as carrier for growth hormone: in vitro characterization of loading and release.

Previous studies concerning bone drug delivery systems have provided little data about the amount of drug loaded, one of the essential factors for determining the dose/effect relationship. To investigate this factor, an adsorption method involving a therapeutic agent was tested in vitro on an apatitic calcium phosphate (AP). One milligram of human growth hormone (hGH) was deposited onto 0.1, 0.15, and 0.2 g of AP powder over a period of 24 h at 37 degrees C. The amount of hGH loaded was determined by subtracting the dose recovered from that applied on AP. The results show that 1 g of AP absorbed 9.48 mg of hGH. From 0.1 and 0.15 g of hGH-loaded AP, hGH was released in vitro for 2 and 3 weeks, respectively, with a 50% time release (T1/2) at 30 h and 72 h, respectively, for the two quantities. The amount of drug loaded and the determined release kinetics were compatible with the action pattern of hGH, indicating that hGH-loaded calcium phosphate supports are suitable for bone-growth promotion.

Apatites↗

Dynamic compaction: a new process to compact therapeutic agent-loaded calcium phosphates.

The sintering stage in the classical process of preparing bone substitution materials prevents therapeutic agents from being loaded into calcium phosphate powder. However, dynamic compaction, a new process, requires no external heat, allowing the therapeutic agent to be incorporated into ceramics. This report presents the results of an in vitro study of therapeutic agents associated with calcium phosphate powder and involving this new process. A mixture of vancomycin lyophilized powder (0.15 g) and biphasic calcium phosphate (BCP) powder (1.85 g) was compacted. In addition, 2 ml of human growth hormone (1 mg ml-1) were associated with BCP powder by physical adsorption on bead surfaces before compaction. Detection by monoclonal antibodies and sodium dodecyl sulphate polyacrylamide gel electrophoresis demonstrated the structural integrity of the two therapeutic agents after consolidation. This new compaction process should be useful in developing ceramics that contain a therapeutic agent.

Adsorption↗

Risks of reusing coronary angioplasty catheters: results of an experimental study.

This experimental study was conducted to evaluate the microbiological and mechanical risks of reusing angioplasty catheters after decontamination and resterilization. The catheters studied were decontaminated in an ultrasound chamber, rinsed, dried, wrapped, and resterilized at 25 or 35 Kgray. Sterility checks performed on catheters cut into three segments concerned bacteria, mushrooms, yeasts, and pyrogens. The surface condition of the balloons was studied by scanning electron microscopy. The mechanical properties analyzed were balloon diameter and bursting pressure and the mean resistance of the catheter body to breakage. Seventy angioplasty catheters of three different types (rapid exchange, coaxial, and on-wire balloon catheter) were tested. Decontamination proved insufficient owing to the persistence of cellular elements on the balloon surface and the presence of pyrogens. Sterility of the material was not ensured with an irradiation of 25 Kgray. It was probable but not certain with 35 Kgray, since an inhibitory effect on micro-organism growth was noted. Mechanical properties were not modified significantly. Our results do not favor the reuse of coronary angioplasty catheters. Better decontamination is desirable but difficult to obtain because of the adhesion of cellular elements to the polymers composing the catheters. Although our results are not necessarily applicable to all resterilization protocols, they indicate that teams desiring to reuse angioplasty material should first test the validity of their procedure for decontamination and resterilization.

Angioplasty, Balloon, Coronary↗