Effects on MRI due to altered rf polarization near conductive implants or instruments.

In magnetic resonance imaging near metal parts variations in radio frequency (rf)-amplitude and of receive sensitivity must be considered. For loop structures, e.g., vascular stents, B1 produces rf eddy currents in accordance to Faraday's law; the B1-related electrical rf field E1 injects directly to elongated structures (e.g., wires). Locally, the rf magnetic field Bl,ind (induced B1) is superimposed onto the rf field from the transmitter coil, which near the metal can dominate spin excitation. Geometry and arrangement of the parts determine the polarization of B(1,ind). Components parallel to B0 are of special interest. A copper sheet (100 mm x 15 mm, 3 mm thick) and a 27 cm long copper wire were examined in a water phantom using the spin-echo (SE) technique. In addition to rf-amplitude amplification, rf-phase shift due to z components of B(1,ind) could be detected near the metallic objects. Periodic rf-amplitude instabilities had an amplified effect for phase-shifted regions. Phase-encoding artifacts occurred as distinct ghosts (TR=200 ms) or band-like smearing (TR=201 ms) from affected spin ensembles. SE phase imaging can potentially be used in interventional magnetic resonance imaging for background-free localization of metallic markers.

Algorithms↗

Metal artifacts caused by gradient switching.

In metal parts, e.g., implants or instruments, eddy currents can be induced from gradient switching if positioned off-center inside the MR scanner. For the first time, a systematic analysis of related artifacts was performed. Current strength increases in conjunction with increasing size of the part, increasing electrical conductivity, distance from isocenter, and increasing gradient strengths. A xy-plane oriented copper ring (d(o) = 20 mm, d(i) = 15 mm, 2 mm thick) was examined at isocenter and at x = 15 cm, y = z = 0. Comparisons of xy-, xz-, and yz-slices, recorded for both possibilities to select encoding directions, revealed effects from ramp-down of the slice-selection and ramp-up of the read-out gradient. Near the metal part, temporary inhomogeneities were superimposed to the static field and spin-dephasing signal loss resulted, despite using spin-echo technique. Artifacts depended on excitation and read-out bandwidth. For an equivalent titanium ring, conductivity related effects could not be ascertained but distinct susceptibility effects occurred. MR compatibility of implants/instruments therefore requires both low susceptibility and low conductivity.

Artifacts↗

Compensation of magnetic field distortions from paramagnetic instruments by added diamagnetic material: measurements and numerical simulations.

In minimally invasive procedures guided by magnetic resonance (MR) imaging instruments usually are made of titanium or titanium alloys (e.g., nitinol), because other more MR-compatible materials often cannot provide sufficient mechanical properties. Artifacts depending on susceptibility arise in MR images due to incorrect spatial encoding and intravoxel dephasing and thereby hamper the surgeon's view onto the region of interest. To overcome the artifact problem, compensation of the paramagnetic properties by diamagnetic coating or filling of the instruments has been proposed in the literature. We used a numerical modeling procedure to estimate the effect of compensation. Modeling of the perturbation of the static magnetic field close to the instruments reflects the underlying problem and is much faster and cost efficient than manufacturing prototypes and measuring artifact behavior of these prototypes in the MR scanner. A numerical model based on the decomposition of the susceptibility distribution in elementary dipoles was developed by us. The program code was written object oriented to allow for both maximum computational speed and minimum random access memory. We used System International units throughout the modeling for the magnetic field, allowing absolute quantification of the magnetic field disturbance. The field outside a simulated needlelike instrument, modeled by a paramagnetic cylinder (out of titan, chi =181.1) of length 8.0 mm and of diameter 1.0 mm, coated with a diamagnetic layer (out of bismuth, chi=-165.0) of thickness 0, 0.1, 0.2, 0.3, and 0.4 mm, was found to be best compensated if the cross-sectional area of the cylinder, multiplied by the absolute susceptibility value of the cylinder material, is equal to the cross-sectional area of the coating, multiplied by the absolute susceptibility value of the coating material. At the extremity of the coated cylinder an uncompensated field distortion was found to remain. We studied various tip shapes and geometries using our computational model: Suitable diamagnetic coating or filling of paramagnetic instruments clearly reduced tip artifacts and diminished the dependency of artifact size on orientation of the instrument with respect to B0 in the numerical studies. We verified the results of the simulations by measuring coated and uncoated titanium wires in a 1.5 T MR scanner.

Computer Simulation↗

rf enhancement and shielding in MRI caused by conductive implants: dependence on electrical parameters for a tube model.

Radio frequency (rf) eddy-currents induced in implants made of conductive material might cause significant image artifacts in magnetic resonance imaging (MRI) such as shielding of the lumen of vascular stents. rf alteration near metal parts was assessed theoretically in the approximation of alternating current electrodynamics: The implant was modeled as tube with diameter d(o), resistance R, and reactance Y, constituting the secondary winding of a transformer. The transmitter coil of the scanner acted as primary winding and generated the linearly polarized rf field B1,app. Tube axis was assumed parallel to B1,app. The results of the calculations were as follows: Ninety percent of the applied rf-field amplitude is reached in the lumen at a ratio chi=R/Y approximately 2. A rapid drop occurs with the reduction of chi, whereas a further increase of chi causes only a small effect. With chi approximately 1/d(o)(Y approximately d2o,R approximately d(o)), conditions for rf alteration clearly depend on the diameter of the tube. Inside tubes with smaller diameter, rf shielding is less pronounced. rf alteration increases in good approximation with the square root of the strength of the static field B0. The following experiments were carried out: Tubes of similar diameter (d(o) approximately 8 mm) made of material of different conductivity (Cu, Nitinol, carbon fiber reinforced plastic with three different fiber structures) were examined at B0=0.2 and 1.5 T in water phantoms. Tube axis was aligned perpendicular to B0 and spin-echo technique was applied. Local rf enhancement near the outer surface of the metal tubes was detected applying manual reduction of the transmitter amplitude. Shielding inside a carbon fiber tube with d(o) approximately 8 mm and inside a smaller tube with d(o)=3.3 mm was compared. Both tubes showed the same wall structure and thickness (d(w)=0.4 mm). All measurements confirmed the theoretical results. Consequences for the construction of vascular stents are discussed, as well as problems with image artifacts due to rf enhancement near solid conductive implants.

Animals↗

Sodium 3-D MRI of the human torso using a volume coil.

Sodium MR imaging is considered to provide clinically important information about the human body that is not achievable by hydrogen-based approaches. However, due to the low natural abundance in biological tissues, sodium signals usually lead to low spatial resolution, low SNR, and long acquisition times compared to conventional 1H imaging, even using well-adapted surface coils. For our study, a volume coil was designed with nearly homogeneous excitation/receive characteristics and a suitable geometry fitting the human torso. A sufficient penetration throughout the entire thorax, abdomen, or pelvis is provided allowing for sodium imaging of the kidneys, the liver with gall bladder, or the myocardium. All measurements were performed on a 1.5 T whole body scanner using a spoiled 3-D gradient echo sequence. Imaging parameters TE, TR, and readout bandwidth were optimized for sensitive recording of the sodium component with slow transverse relaxation. Nonselective RF excitation pulses with a duration of 2.5 ms and rectangular shape were applied to avoid SAR problems. Narrow receiver bandwidth and excitation near the Ernst angle provided clinically practicable examinations with measuring times of less than 15 min at a spatial resolution of 8 x 8 x 8 mm3. Under these conditions, SNR of 11 for the kidneys and vertebral disks, 9 for the spinal canal, and 6 for the liver was achieved. A special 3-D spin echo sequence was used to determine T2, times which resulted to 15.3 +/- 1.1 ms for liver, 27.7 +/- 7.2 ms for kidneys, and 24.0 +/- 4.7 ms for the content of the spinal canal.

Abdomen↗

Numerical modeling of needle tip artifacts in MR gradient echo imaging.

Exact determination of needle tip position is obsolete for interventional procedures under control of magnetic resonance imaging (MRI). Exact needle tip navigation is complicated by the paramagnetism of microsurgical instruments: Local magnetic field inhomogeneities are induced resulting in position encoding artifacts and in signal voids in the surrounding of instruments and especially near their tips. The artifacts generated by the susceptibility of the material are not only dependent on the material properties themselves and on the applied MRI sequences and parameters, but also on the geometric shape of the instruments and on the orientation to the static magnetic field in the MR unit. A numerical model based on superposition of induced elementary dipole fields was developed for studying the field distortions near paramagnetic needle tips. The model was validated by comparison with experimental data using field mapping MRI techniques. Comparison between experimental data and numerical simulations revealed good correspondence for the induced field inhomogeneities. Further systematic numerical studies of the field distribution were performed for variable types of concentric and asymmetric tip shapes, for different ratios between tip length and needle diameter, and for different orientations of the needle axis in the external static magnetic field. Based on the computed local inhomogeneities of the magnetic field in the surroundings of the needle tips, signal voids in usual gradient echo images were simulated for a prediction of the artifacts. The practically relevant spatial relation between those artifacts and the hidden tip of the needle was calculated for the different tip shapes and orientations in the external field. As needle tip determination is crucial in interventional procedures, e.g., in taking biopsies, the present model can help to instruct the physician prior to surgical interventions in better estimating the needle tip position for different orientations and needle tip shapes as they appear in interventional procedures. As manufacturing prototypes with subsequent measurements of artifacts in MRI are a costly procedure the presented model may also help to optimize shapes of needle tips and of other parts of MR-compatible instruments and implants with low expense prior to production if some shape parameters can be chosen freely.

Artifacts↗