PubMed Health⌕ Search

Biomedical subjects

Greg E Collins

Publications and source records attributed to Greg E Collins.

10 recordsLinked to original sources

Electrochemical coding for multiplexed immunoassays of proteins.

An electrochemical immunoassay protocol for the simultaneous measurements of proteins, based on the use of different inorganic nanocrystal tracers is described. The multiprotein electrical detection capability is coupled to the amplification feature of electrochemical stripping transduction (to yield fmol detection limits) and with an efficient magnetic separation (to minimize nonspecific adsorption effects). The multianalyte electrical sandwich immunoassay involves a dual binding event, based on antibodies linked to the nanocrystal tags and magnetic beads. Carbamate linkage is used for conjugating the hydroxyl-terminated nanocrystals with the secondary antibodies. Each biorecognition event yields a distinct voltammetric peak, whose position and size reflects the identity and level, respectively, of the corresponding antigen. The concept is demonstrated for a simultaneous immunoassay of beta(2)-microglobulin, IgG, bovine serum albumin, and C-reactive protein in connection with ZnS, CdS, PbS, and CuS colloidal crystals, respectively. These nanocrystal labels exhibit similar sensitivity. Such electrochemical coding could be readily multiplexed and scaled up in multiwell microtiter plates to allow simultaneous parallel detection of numerous proteins or samples and is expected to open new opportunities for protein diagnostics and biosecurity.

Animals↗

Microchip capillary electrophoresis with electrochemical detection of thiol-containing degradation products of V-type nerve agents.

A microchip protocol for the capillary electrophoresis separation and electrochemical detection of thiol-containing degradation products of V-type nerve agents is described. The microchip assay relies on the derivatization reaction of 2-(dimethylamino)ethanethiol (DMAET), 2-(diethylamino)ethanethiol (DEAET), and 2-mercaptoethanol (ME) with o-phthaldialdehyde in the presence of the amino acid valine along with amperometric monitoring of the isoindole derivatives. Both off-chip and on-chip derivatization reactions have led to highly sensitive and rapid detection of the thiol degradation products. Various parameters influencing the derivatization, separation, and detection processes were examined and optimized. These include the amino acid co-reagent, reagent-mixing ratio, reaction time, injection time, separation voltage, and detection potential. The chip microsystem offers a rapid (<4 min) simultaneous detection of micromolar concentrations of DMAET, DEAET, and ME. Linear calibration plots were observed for the V-type nerve agent thiol degradation products, along with good stability and reproducibility (RSD < 8.0%). Detection limits of 5 and 8 microM were obtained for the off-chip reaction of DMAET and DEAET, respectively, following a 2-s injection. The suitability for assays of environmental matrixes was demonstrated for the determination of DMAET and DEAET in untreated tap and river water samples. The favorable analytical performance makes the new microfluidic device attractive for addressing the needs of various security scenarios.

Biodegradation, Environmental↗

Compact, high voltage power supply for the lab-on-a-chip.

The design, construction and operation of a simple, inexpensive and compact high voltage power supply (HVPS) for use in conjunction with a simple cross capillary electrophoresis microchip is presented. The microchip HVPS utilizes a single high voltage power supply (15 kV), a voltage-divider network, to give the voltages necessary to operate a gated injection valve, and two high voltage relays for switching between the open and closed gate sequences of the injection. In order to accommodate the application of different simple cross microchip dimensions, a set of equations for defining the resistor network and ensuring proper gate performance are presented.

Electric Power Supplies↗

Vapor and liquid phase detection of cyanide on a microchip.

A capillary electrophoresis microchip is used to selectively and sensitively monitor cyanide levels in both vapor (HCN((g))) and aqueous (NaCN in drinking water) phases. Laser-induced fluorescence detection is applied using a violet diode laser to monitor the fluorescent isoindole derivative formed by the reaction of cyanide with 2,3-naphthalenedicarboxaldehyde (NDA) and taurine. Air sampling of hydrogen cyanide is achieved using a miniature impinger (2 mL), giving collection efficiencies as high as 79% for a sampling rate of 1.0 L/min and a 10 s sampling time (relative standard deviation RSD: 2.7% for n = 5). Following the addition of NDA and taurine to either the vapor phase impinger sample or an aqueous drinking water sample, the NDA/cyanide derivative can be detected in just over 40 s on the microchip, giving a detection limit of 0.56 microg/L and a linear dynamic range from 0.56 microg/L-2.4 mg/L. The detection limit for hydrogen cyanide in air was determined to be 2.3 ppb (mole%). On-chip derivatization of cyanide by NDA was successful, although a 50% decrease in signal intensity was observed due to insufficient time for completion of the reaction on the microchip. A number of different interferents were examined, and only iron(II) and chlorine showed any interference due to their capability for masking the presence of cyanide by reacting with free cyanide in solution.

Air Pollution↗

Separation of thiol and cyanide hydrolysis products of chemical warfare agents by capillary electrophoresis.

The fluorescence derivatizing agent, o-phthalaldehyde (OPA), has been applied to the separation and detection of cyanide and several structurally similar thiols by capillary electrophoresis (CE)-laser induced fluorescence (LIF). Of particular interest to this investigation was the separation of 2-dimethylaminoethanethiol, 2-diethylaminoethanethiol, and cyanide, each of which are hydrolysis products or hydrolysis product simulants of the chemical warfare (CW) agents O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX), O-isobutyl S-2-diethylaminoethyl methylphosphonothiolate (R-VX), and tabun (GA). Other structurally similar thiols simultaneously resolved by this method include 1-pentanethiol and 2-mercaptoethanol. Instrumental parameters were probed and optimum values for capillary length (50 cm) and inner diameter (75 microm), injection time (30 s) and field strength (15 kV) were determined. Sample stacking methods enabled detection limits of 9.3 microg/L for cyanide, 1.8 microg/L for 2-diethylaminoethanethiol, 35 microg/L for 2-dimethylaminoethanethiol, 15 microg/L for 2-mercaptoethanol, and 89 microg/L for 1-pentanethiol. The linearity of the method was verified over an order of magnitude and the reproducibility was found to be 3.0%.

Chemical Warfare Agents↗

Microscale solid-phase extraction system for explosives.

A simple, semi-automated, microcolumn solid-phase extraction (SPE) system is optimized for the extraction, preconcentration and HPLC analysis of seven different explosives and explosive derivatives contaminating seawater, river water and well water samples. The microcolumns were constructed from 1/16 in. O.D. PTFE tubing (1 in.=2.54 cm) packed with 0.5-1.5 mg of SPE material. LiChrolut EN or Porapak R. The extraction system consisted of two syringe pumps and several solenoid valves. Optimal detection limits were realized when the sample water flow-rate was maximally increased within the limits of the pump, 5-10 ml/min (despite exceeding the breakthrough threshold of the SPE microcolumn), and when the eluate volume collected from the column was minimized, <5 microl (despite very low recovery percentages).

Automation↗

Nonaqueous based microchip separation of toxic metal ions using 2-(5-bromo-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino)phenol.

The colorimetric metal chelating agent, 2-(5-bromo-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino)phenol (5-Br-PAPS), was demonstrated on a capillary electrophoresis microchip in the separation and detection of six metal ions of environmental concern, Cd2+, Pb2+, Cu2+, Co2+, Ni2+, and Hg2+. The inclusion of methanol in the buffer was found to improve both the separation efficiency and sensitivity, in addition to making the technique directly amenable to the application of solid-phase extraction. The combination of metal chelation with solid-phase extraction on a C18 silica gel microcolumn gave several hundred fold improvements in detection limits for the CE microchip measurements of toxic metal ions in water and extracted from a solid Plexiglas surface.

Azo Compounds↗

Analysis of inorganic and small organic ions with the capillary electrophoresis microchip.

Capillary electrophoresis microchip devices are receiving considerable attention due to their versatility, portability, and sample handling capabilities. This article is a comprehensive review of the analysis of inorganic and small, charged organic species on microchip platforms. The application of conductivity, amperometry, laser-induced fluorescence, absorbance, and chemiluminescence detection methods are discussed. The potential utilization of these devices for miniaturized analytical systems is described.

Electrochemistry↗

Electrophoretic microchip with dual-opposite injection for simultaneous measurements of anions and cations.

A novel dual-injection poly(methylmethacrylate) (PMMA) microchip electrophoretic system has been designed and fabricated for simultaneous measurements of anions and cations using a single channel and detection device. It consists of two sample reservoirs, on both sides of a common separation channel. Anions and cations can be simultaneously electrokinetically injected into both ends of the separation channel. Due to lower electroosmotic flow in polymer channels compared to glass ones, the cations and anions migrate in opposite directions and can be separated from each other and detected using a movable contactless conductivity detector (MCCD) positioned around the center of the separation channel. The effects of the detector position and of the separation voltage on the response and resolution have been studied and optimized for simultaneous determination of six low-energy explosive-related ions, including ammonium, methyl ammonium, sodium, chloride, nitrate, and perchlorate in a single analytical run (of ca. 3 min). Simultaneous detection of nerve-agent degradation products along with explosive-related anions and cations is also demonstrated. The versatile system can also be used for separately measuring anions or cations. The attractive behavior of the dual-opposite injection microchip offers great promise for a wide range of applications, including "total ion analysis" of various samples.

Anions↗

Measurements of chemical warfare agent degradation products using an electrophoresis microchip with contactless conductivity detector.

This paper reports on a microfluidic device for the screening of organophosphonate nerve agent degradation products. The miniaturized system relies on an efficient chip-based separation of alkyl methylphosphonic acids (breakdown products of Sarin, Soman, and VX nerve agents) followed by their sensitive contactless conductivity detection. Experimental parameters relevant to the separation and detection processes have been optimized to yield high sensitivity (with 48-86 microg L(-1) detection limits), fast response (50 s for a three alkyl methylphosphonic acid mixture), high precision (RSD = 3.8-5.0%), and good linearity (over the 0.3-100 mg L(-1) range). Applicability to natural (river) water samples is demonstrated. The new microsystem offers promise for monitoring degradation products of chemical warfare agents, with advantages of speed/warning, efficiency, portability, sample size, and cost compared to conventional ion chromatography or capillary electrophoresis systems.

Chemical Warfare Agents↗