[Metallic biomaterials for coronary stents].

The introduction of coronary stents is a milestone in interventional cardiology. Two landmark studies have shown that stainless steel stents significantly decrease the restenosis rate as compared to balloon angioplasty. This fact led to a marked increase of stent implantation since the first stent implantation by Jacques Puel in 1986. Although the concept of coronary stenting significantly improved the interventional therapy of coronary artery disease, restenosis remains a major unsolved drawback of this technique. In addition to procedure and disease related factors like implantation pressure and plaque burden, data suggest that the stent as a medical implant plays a crucial role in the process of neointima formation. Since its introduction in cardiology, more than 50 different stents of different configuration and material have been developed. Although recent publications report of promising results using biodegradable materials, almost all coronary stents commercially available at the moment are made of metallic alloys. Whereas first generation stents were made exclusively from stainless steel and only minor interest was focussed on the stent material in the manufacture of coronary stents, recent studies strongly suggest that the metallic alloy used has a direct impact on the extent of neointima formation. Thus, metallic alloys differ not only with respect to mechanical features, but also by their biocompatible properties. These two factors are of major importance in the induction of vessel wall injury, inflammatory processes and cell proliferation. In the first part, the present paper reviews the metallurgic characteristics of metallic materials, which are currently used or under investigation in the production of coronary stents. In the second part, clinical and experimental results are summarized with respect to their biocompatibility and impact on the process of restenosis formation.

Biocompatible Materials↗

A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits.

OBJECTIVE: To determine whether corrodible materials may be safely used as biodegradable cardiovascular implants. DESIGN: Corrodible iron stents (> 99.8% iron) were produced from pure iron and laser cut with a stent design similar to a commercially available permanent stent (PUVA-AS16). A total of 16 NOR-I stents were implanted into the native descending aorta of 16 New Zealand white rabbits (mean luminal diameter at the implantation site 3.4 mm, balloon diameter to vessel diameter ratio 1.13). RESULTS: No thromboembolic complications and no adverse events occurred during the follow up of 6-18 months. All stents were patent at repeat angiography after 6 (n = 9), 12 (n = 5), and 18 months (n = 2) with no significant neointimal proliferation, no pronounced inflammatory response, and no systemic toxicity. CONCLUSIONS: This initial in vivo experience suggests that degradable iron stents can be safely implanted without significant obstruction of the stented vessel caused by inflammation, neointimal proliferation, or thrombotic events.

Absorbable Implants↗

[Biophysical study of coronary stents: which factors influence the dilatation and recoil behavior?].

In Europe more than fifty stents are currently available for the therapy of coronary artery disease. Nonetheless it is unknown whether material and design influence the stent's behavior. We have studied the recoil and dilatation behavior of five currently available stainless steel (316L) stents compared to stent prototypes made of pure titanium. Furthermore we have investigated how the behavior is influenced by the process of crimping. The aim of this work was to determine material and design characteristics, which influence the recoil and dilatation behavior. The 316L stents showed a homogeneous behavior (plateau pressure min. 1.15 +/- 0.01 atm, max. 0.26 +/- 0.03 atm, recoil min. 0.15 +/- 0.03%, max. 0.26 +/- 0.03%). The titanium stent showed a linear response to the balloon expansion. This was seen in a significantly lower plateau pressure (0.43 +/- 0.15 atm, p < 0.001). Despite the material characteristics of titanium, there were no significant differences in the recoil behavior (0.28 +/- 0.02%). Crimping leads to stent alterations which result in a significantly higher plateau pressure (1.9 +/- 0.07 atm vs. 2.7 +/- 0.58 atm, p < 0.001) and a reduced end-diameter (3.6 +/- 0.02 mm vs. 3.54 +/- 0.05 mm, p < 0.005). The presented data show that the dilatation behavior is relying on the stent material while the recoil is strongly influenced by the stent design.

Angioplasty, Balloon, Coronary↗

Multichannel magnetocardiographic measurements with a physical thorax phantom.

Artificial dipolar sources were applied inside a physical thorax phantom to experimentally investigate the accuracy obtainable for non-invasive magnetocardiographic equivalent current dipole localisation. For the measurements, the phantom was filled with saline solution of electrical conductivity 0.21 S m-1. A multichannel cardiomagnetometer was employed to record the magnetic fields generated by seven dipolar sources at distances from 25 mm to 145 mm below the surface of the phantom. The inverse problem was solved using an equivalent current dipole in a homogeneous boundary element torso model. The dipole parameters were determined with a non-linear least squares fitting algorithm. The signal-to-noise ratio (SNR) and the goodness of fit of the calculated localisations were used in assessing the quality of the results. The dependence between the SNR and the goodness of fit was derived, and the results were found to correspond to the model. With SNR between 5 and 10, the average localisation error was found to be 9 +/- 8 mm, while for SNR between 30 and 40 and goodness of fit between 99.5% and 100%, the average error reduced to 3.2 +/- 0.3 mm. The SNR values obtained in this study were also compared with typical clinical values of SNR.

Cardiology↗

Source localization in an inhomogeneous physical thorax phantom.

The influence of lung inhomogeneities on focal source localizations in electrocardiography (ECG) and magnetocardiography (MCG) is investigated. A realistically shaped physical thorax phantom with cylindrical lung inhomogeneities is used for electric and magnetic measurements. The lungs are modelled with a special ionic exchange membrane which allows different conductivity compartments without influencing the free ionic current flow. The dipolar current sources are composed of platinum wire and located at different depths and directions between the lung inhomogeneities. We localized the current dipoles with different boundary element method (BEM) models, based on electrical data and simultaneous electrical and magnetic data. Our results indicate the possibility of superadditive information gain by combining electrical and magnetic data for source reconstructions. We found a significant influence of the inhomogeneities on both the calculated source location and the calculated source strength. Mislocalizations of up to 16 mm and wrong dipole strengths of up to 52% were obtained when the lung inhomogeneities were not taken into account for source localization. Dipoles parallel to the lungs showed a larger localization error in depth than dipoles perpendicular to the lungs. We conclude that the incorporation of lung inhomogeneities will improve source localization accuracy in ECG and MCG.

Body Surface Potential Mapping↗

The influence of conductivity changes in boundary element compartments on the forward and inverse problem in electroencephalography and magnetoencephalography.

Source localization based on magnetoencephalographic and electroencephalographic data requires knowledge of the conductivity values of the head. The aim of this paper is to examine the influence of compartment conductivity changes on the neuromagnetic field and the electric scalp potential for the widely used three compartment boundary element models. Both the analysis of measurement data and the simulations with dipoles distributed in the brain produced two significant results. First, we found the electric potentials to be approximately one order of magnitude more sensitive to conductivity changes than the magnetic fields. This was valid for the field and potential topology (and hence dipole localization), and for the amplitude (and hence dipole strength). Second, changes in brain compartment conductivity yield the lowest change in the electric potentials topology (and hence dipole localization), but a very strong change in the amplitude (and hence in the dipole strength). We conclude that for the magnetic fields the influence of compartment conductivity changes is not important in terms of dipole localization and strength estimation. For the electric potentials however, both dipole localization and strength estimation are significantly influenced by the compartment conductivity.

Electric Conductivity↗

Influence of tissue resistivities on neuromagnetic fields and electric potentials studied with a finite element model of the head.

Modeling in magnetoencephalography (MEG) and electroencephalography (EEG) requires knowledge of the in vivo tissue resistivities of the head. The aim of this paper is to examine the influence of tissue resistivity changes on the neuromagnetic field and the electric scalp potential. A high-resolution finite element method (FEM) model (452,162 elements, 2-mm resolution) of the human head with 13 different tissue types is employed for this purpose. Our main finding was that the magnetic fields are sensitive to changes in the tissue resistivity in the vicinity of the source. In comparison, the electric surface potentials are sensitive to changes in the tissue resistivity in the vicinity of the source and in the vicinity of the position of the electrodes. The magnitude (strength) of magnetic fields and electric surface potentials is strongly influenced by tissue resistivity changes, while the topography is not as strongly influenced. Therefore, an accurate modeling of magnetic field and electric potential strength requires accurate knowledge of tissue resistivities, while for source localization procedures this knowledge might not be a necessity.

Adipose Tissue↗

[Effect of boundary element discretization on forward calculation and the inverse problem in electroencephalography and magnetoencephalography].

Modelling in magnetoencephalography (MEG) and electroencephalography (EEG) is increasingly based on the boundary element method (BEM). We quantify the influence of boundary element discretization on the neuromagnetic and neuroelectric forward and inverse problem for different dipole depths, brain regions and the quasispherical correction. In particular we derive standards for the general use of BEM models in MEG/EEG source localization. For this purpose simulation with single current dipoles, and source reconstructions from somatosensory evoked potentials and magnetic fields were employed. It was found that both local and global discretization influence source reconstruction. Only at a minimum triangle side length of 10 mm was it possible to achieve stable results for MEG and EEG. In order to obtain acceptable errors within the stable region, the ratio of dipole depth to triangle side length must not be less than 0.5. The results obtained from a comparison of the different brain regions indicate that the similarity to spherical geometry might well have an influence on the estimated dipole location, but not so much on its strength. Source reconstruction employing quasispherical correction was found to be the most stable, in particular in the case of coarse BEM discretization.

Adult↗

Cardiorespiratory and renal responses to arterial chemoreceptor stimulation by hypoxia or almitrine in men.

1. The cardiorespiratory and renal responses to 3 h of normobaric whole-body hypoxic hypoxia (FiO2 = 0.12) as well as to arterial chemoreceptor stimulation by the oral administration of 100 mg almitrine bismesylate during normoxia were measured in 12 normotensive young men undergoing water diuresis. A third series of responses obtained under comparable conditions in the same subjects served as time controls. 2. No significant changes could be detected over time in the parameters measured in control experiments. The subjects reacted to both whole-body hypoxic hypoxia and to pharmacological chemoreceptor stimulation with significant increases in heart rate, tidal volume, minute ventilation and filtration-fraction. Overall renal vascular resistance rose significantly in hypoxia; increases in renal vascular resistance in almitrine experiments were not significant. 3. Renal fractional lithium excretion decreased significantly in response to whole-body hypoxic hypoxia and increased slightly in response to almitrine. Fractional urine and sodium excretion showed negligible changes. 4. The data indicate that, in humans, both almitrine and whole-body hypoxic hypoxia affect not only alveolar ventilation but also renal haemodynamics. 5. The renal electrolyte excretion pattern suggests that under certain circumstances (e.g. dilated renal vascular bed) acute, but well-tolerated, whole-body hypoxic hypoxia can simultaneously stimulate renal proximal tubular sodium reabsorption and inhibit distal tubular sodium reabsorption. The renal tubular responses also indicate that almitrine may influence renal tubular lithium reabsorption by, thus far, unknown mechanisms.

Adult↗

Cardiorespiratory and renal responses to arterial chemoreceptor stimulation in early hypertension.

The peripheral arterial chemoreceptors (PAC) modify not only cardiorespiratory but also renal hemodynamic and excretory function. There is evidence that in hypertensive animals and humans the reflectoric actions of the PAC on ventilation and circulation differ from those of normotensive subjects. However, the influence of these receptors on kidney function of hypertensive subjects is poorly understood. Cardiorespiratory and renal responses to pharmacological stimulation of PAC by almitrine bismesylate during normoxia were measured in 16 normotensive (NT) and 13 age-matched borderline-hypertensive young men (BHT) undergoing water diuresis. Placebo experiments served as time controls in each subject. NT reacted to almitrine with significant rises in heart rate, minute ventilation, and filtration fraction. Renal vascular resistance tended to increase slightly. In BHT the drug caused a significant rise in heart rate and minute ventilation too, however, this reaction had a longer latency when compared to NT. In contrast to NT, filtration fraction, and renal vascular resistance decreased. Renal fractional sodium and lithium excretion did not show any clear response to almitrine in NT, but decreased in BHT. The results suggest that the weaker ventilatory response in BHT vs. NT might indicate a lower reactivity of their PAC to almitrine. The different reactions of the renal vascular bed to pharmacological chemoreceptor excitation in mild hypertensives might result from a different reactivity of the renal arterioles, whereas the enhanced proximal tubular sodium reabsorption could be due to an exaggerated increase in efferent renal nerve activity.

Adult↗

The physiological stress response and the role of cognitive coping in migraine patients and non-headache controls.

Our study investigated physiological response specificity and cognitive coping in migrainous patients during an achievement task situation. Thirty-three migrainous subjects and thirty-two non-headache controls were subjected to 40 min of demanding cognitive tasks and 20 min of recovery during which cranial and peripheral vasomotor responses were registered as well as electrodermal and myographic activity. Subjects of both groups were randomly assigned to two experimental conditions, a so-called 'spontaneous processing condition' and the 'positive coping treatment'. In this treatment condition subjects received a short training in the conscious use of positive self-statements in stress situations. Though a specific pattern of cranial vasomotor responses in migraine subjects could be verified by group statistics, this pattern was only found in very few individuals. Reliable differences between groups could not be identified in other physiological variables either. The hypothesis that the predicted cranial vasomotor specificity in migraine subjects correlates with negative cognitive coping habits in migraine subjects best revealed in the 'spontaneous processing' condition, was not corroborated. The treatment variation regarding coping produced somewhat paradoxical effects, more relaxed and positive self-evaluation (subjective level) and more arousal (physiological level). Results are discussed for their impact on the psycho-biological model of migraine.

Adaptation, Psychological↗