Diagnostic challenges for multiplexed protein microarrays.

Multiplexed protein analysis using planar microarrays or microbeads is growing in popularity for simultaneous assays of antibodies, cytokines, allergens, drugs and hormones. However, this new assay format presents several new operational issues for the clinical laboratory, such as the quality control of protein-microarray-based assays, the release of unrequested test data and the use of diagnostic algorithms to transform microarray data into diagnostic results.

Algorithms↗

Current perspectives in protein array technology.

This article reviews post-2000 trends in the development of two-dimensional protein microarrays and nanoarrays. Progress in array manufacture, assay design and applications are considered, with an emphasis on issues surrounding the implementation of arrays in clinical diagnostics. These include the effect of factors in the pre-analytical phase (quality of the reagents, sample integrity, etc.), and those in the analytical phase that contribute to inaccuracy and imprecision of an array-based assay. Important requirements for the quality control and quality assurance of protein microarray assays as they move from the research environment into routine clinical application are also discussed.

Protein Array Analysis↗

Opportunities for near-infrared thermal ablation of colorectal metastases by guanylyl cyclase C-targeted gold nanoshells.

Colorectal cancer is the third most common malignancy and the second most common cause of cancer-related mortality worldwide. While surgery remains the mainstay of therapy, approximately 50% of patients who undergo resection develop parenchymal metastatic disease. Unfortunately, current therapeutic regimens offer little improvement to the survival of patients with parenchymal metastases in the liver and lung. In that context, there is a significant unrealized opportunity at the intersection of engineering and biology for the development of novel targeted therapeutic approaches to colorectal cancer metastases. This opportunity exploits the discovery that an intestinal receptor, guanylyl cyclase C, which mediates diarrhea induced by bacterial heat-stable enterotoxins (STs), is over-expressed by metastatic colorectal tumors only. Moreover, it leverages recent advances in the fabrication of metal nanoshells with defined thicknesses absorb near-infrared (NIR) light, resulting in resonance and transfer of thermal energies of more than 40 degrees C. Thus, the conjugation of ST to gold nanoshells, which can undergo resonance excitation by NIR light and emit heat, represents a previously unrecognized approach for the targeted therapy of parenchymal colorectal cancer metastases, specifically to the liver and lung. This article discusses the potential of ST-targeted nanoshells for NIR thermal ablation of metastatic colorectal tumors and highlights the significant challenges and solutions linked to the translation of this emerging technology to patient care.

Biomarkers, Tumor↗

Clinical analysis by microchip capillary electrophoresis.

Clinical analysis often requires rapid, automated, and high-throughput analytical systems. Microchip capillary electrophoresis (CE) has the potential to achieve very rapid analysis (typically seconds), easy integration of multiple analytical steps, and parallel operation. Although it is currently still in an early stage of development, there are already many reports in the literature describing the applications of microchip CE in clinical analysis. At the same time, more fully automated and higher throughput commercial instruments for microchip CE are becoming available and are expected to further enhance the development of applications of microchip CE in routine clinical testing. To put into perspective its potential, we briefly compare microchip CE with conventional CE and review developments in this technique that may be useful in diagnosis of major diseases.

Biomarkers↗

Micropillar array chip for integrated white blood cell isolation and PCR.

We report the fabrication of silicon chips containing a row of 667 pillars, 10 by 20 microm in cross-section, etched to a depth of 80 microm with adjacent pillars being separated by 3.5 microm. The chips were used to separate white blood cells from whole blood in less than 2 min and for subsequent PCR of a genomic target (eNOS). Chip fluid dynamics were validated experimentally using CoventorWare microfluidic simulation software. The amplicon concentrations were determined using microchip capillary electrophoresis and were >40% of that observed in conventional PCR tubes for chips with and without pillars. Reproducible on-chip PCR was achieved using white blood cell preparations isolated from whole human blood pumped through the chip.

Cell Separation↗

Nanobiotechnology: the promise and reality of new approaches to molecular recognition.

Nanobiotechnology is the convergence of engineering and molecular biology that is leading to a new class of multifunctional devices and systems for biological and chemical analysis with better sensitivity and specificity and a higher rate of recognition. Nano-objects with important analytical applications include nanotubes, nanochannels, nanoparticles, nanopores and nanocapacitors. Here, we take a critical look at the subset of recent developments in this area relevant to molecular recognition. Potential benefits of using nano-objects (nanotubes, quantum dots, nanorods and nanoprisms) and nanodevices (nanocapacitors, nanopores and nanocantilevers) leading to an expanded range of label multiplexing are described along with potential applications in future diagnostics. We also speculate on further pathways in nanotechnology development and the emergence of order in this somewhat chaotic, yet promising, new field.

Biotechnology↗

Validation and quality control of protein microarray-based analytical methods.

The microarray has emerged as an important format for simultaneous analysis of tens of thousands of substances present in a sample. Successful adaptation of microarray assays to clinical diagnostics will require particular attention to issues of quality control and quality assurance. Results of an assay can be compromised by a number of preanalytical factors including the quality of the reagents (e.g., the microarray and the detection reagents) and the integrity of the sample. Similarly, numerous factors in the analytical phase of a microarray assay, including changes in the reaction conditions and calibration, can contribute to inaccuracy and imprecision. Furthermore, a microarray combines many reagents or samples in a single device and therefore presents additional issues not usually encountered in discrete testing of a single analyte in a single sample. Various strategies (e.g., replicate analysis, array orientation control features, on-array controls, normalization) have been implemented to control and assess analytical factors that might compromise data generated from a microarray. The current range of measures taken to ensure the analytical accuracy and quality of data generated from protein microarrays is reviewed in the context of the lessons learned from DNA microarrays. The special considerations for protein microarrays as they transition from research into routine clinical analysis and the resulting quality control of clinical test results generated using such devices are discussed.

Computational Biology↗

Miniaturized detection technology in molecular diagnostics.

Miniaturization of genetic tests represents the convergence of molecular biology and engineering and is leading to a new class of small analyzers and test systems for genetic testing with improved analytical characteristics. Miniaturization initially focused on devices that contained micrometer-sized features designed for a particular analytical purpose (e.g., filters for cell isolation and chips for capillary electrophoresis). Now, the focus is shifting to analytical applications based on nano-sized objects such as nanotubes, nanochannels, nanoparticles, nanopores and nanocapacitors. These nanofabricated objects provide new tools for sequencing of nucleic acids and rapid, multiplexed, nucleic acid detection.

Animals↗

Surface effects on PCR reactions in multichip microfluidic platforms.

We evaluated the compatibility of several common plastics, commercially available plastic tubing and disposable syringes which might be useful in the construction of microfluidic platforms with respect to the polymerase chain reaction (PCR). A simple and inexpensive plastic test module was constructed in order to evaluate some of the construction plastics. We also investigated the effect of addition of PEG 8000 to PCR reaction mixtures on the compatibility of materials. These studies identified several common plastics, plastic tubing, and disposable syringes which were compatible with the PCR reaction.

Equipment Design↗

Increased amplification efficiency of microchip-based PCR by dynamic surface passivation.

Surface passivation is critical for effective PCR using silicon-glass chips. We tested a dynamic polymer-based surface passivation method. Polyethylene glycol 8000 (PEG 8000) or polyvinylpyrrolidone 40 (PVP-40) applied at 0.75% (w/v) in the reaction mixture produced significant surface passivation effects using either native or SiO2-precoated silicon-glass chips. PCR amplification was achieved from human genomic DNA as a template as well as from human lymphocytes. The dynamic surface passivation effect of PEG 8000 remained similar under both conditions. Dynamic surface passivation offers a simple and cost-effective method to make microfabricated silicon-glass chips PCR friendly. It can also be used in combination with static passivation (silicon oxide surface layer) to further improve PCR performance using silicon-glass PCR chips.

Cell Separation↗

Mutation detection using ligase chain reaction in passivated silicon-glass microchips and microchip capillary electrophoresis.

The ligase chain reaction (LCR) following PCR is one of the most sensitive and specific methods for detecting mutations, especially single nucleotide polymorphisms (SNPs). Performing LCR in microchips remains a challenge because of the inhibitory effect of the internal surfaces of silicon-glass microchips. We have tested a dynamic polymer-based surface passivation method for LCR conducted in oxide-coated silicon-glass microchips. The combination of polyvinylpyrrolidone 40 (PVP-40) at 0.75% (w/v) with an excess of the ligase produced successful LCR in the silicon-glass microchips, with yields of ligated primers comparable to reactions performed in conventional reaction tubes. Ligated primers were detected and quantified simply and conveniently using microchip capillary electrophoresis.

DNA Mutational Analysis↗

Genotyping on a thermal gradient DNA chip.

Silicon-based chips with discrete, independently temperature-controlled islands have been developed for use in DNA microarray hybridization studies. Each island, containing a heater made of a diffusion layer and a temperature sensor based on a p-n junction, is created on a silicon dioxide/nitride surface by anisotropic etching. Different reactive groups are subsequently added to the surface of the islands, and allele-specific oligonucleotide probes are attached to discrete spots on the chip. Hybridization is performed with Cy5-tagged single-stranded targets derived by PCR from genomic DNA. Results are assessed by measuring fluorescence of bound dye-tagged targets after hybridization and washing. Temperatures at each island can be set at different values to obtain optimal distinction between perfect matches and mismatches. This approach facilitates definition of optimal temperatures for probe/target annealing and for distinction between perfectly matched versus mismatched solution-phase targets. The thermal gradient DNA chips were then tested for genotyping, and the results for four different loci in two genes are presented. Unambiguous typing was achieved for clinically relevant loci within the factor VII and hemochromatosis genes.

Factor VII↗

Fabrication of plastic microchips by hot embossing.

Plastic microchips with microchannels (100 microm wide, 40 microm deep) of varying designs have been fabricated in polymethylmethacrylate by a hot embossing process using an electroform tool produced starting with silicon chip masters. Hot-embossed chips were capped with a polymethylmethacrylate top using a proprietary solvent bonding process. Holes were drilled through the top of the chip to allow access to the channels. The chips were tested with fluid and shown to fill easily. The seal between the top of the chip and the hot embossed base was effective, and there was no leakage from the channels when fluid was pumped through the microchannels. The chips were also tested with a semen sample and the plastic chip performed identically to the previous silicon-glass and glass versions of the chip. This microfabrication technique offers a viable and potentially high-volume low cost production method for fabricating transparent microchips for analytical applications.

Hot Temperature↗