Flat-panel x-ray detector using amorphous silicon technology. Reduced radiation dose for the detection of foreign bodies.

Abstract

RATIONALE AND OBJECTIVES: The authors evaluate a new flat-panel x-ray detector (FD) with respect to foreign body detection and reduction of radiation dose compared with screen-film radiography. METHODS: Flat-panel x-ray detector is based on amorphous silicon technology and uses a 1 k x 1 k photo-detector matrix with a pixel size of 143 x 143 microns and 12-bit digital output. A thallium-dotted cesium iodide scintillation layer converts x-rays into light. An ex vivo experimental model was used to determine the detectability of foreign bodies. Foreign bodies with varying sizes were examined: glass with and without addition of lead, bone, aluminium, iron, copper, gravel fragments, and graphite. Four hundred observation fields were examined using conventional radiography (speed, 400; system dose: 2.5 microGy) as well as FD with a simulated speed of 400, 800, 1200, and 1600, corresponding to a detector dose of 2.5 microGy, 1.25 microGy, 0.87 microGy, and 0.625 microGy, respectively. Four independent radiologists performed receiver operating characteristic analysis of 8000 observations. RESULTS: Flat-panel x-ray detector with a simulated speed of 400 was significantly superior (P = 0.012) to screen-film radiography (speed, 400). At a simulated speed of 800 and 1200 FD yielded results equivalent to screen-film radiography. Flat-panel x-ray detector was significantly inferior to screen-film radiography at a simulated speed of 1600 (P = 0.012). CONCLUSIONS: Flat-panel x-ray detector technology allows significant reduction in radiation dose compared with screen-film radiography without loss of diagnostic accuracy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Völk, M Strotzer, J Gmeinwieser, J Alexander, R Fründ, J Seitz, C Manke, M Spahn, S Feuerbach. 1997. Flat-panel x-ray detector using amorphous silicon technology. Reduced radiation dose for the detection of foreign bodies.. https://doi.org/10.1097/00004424-199707000-00001

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Case report: urinary retention secondary to a foreign body in the male urethra.

We report the case of a male patient who presented to the Emergency Department with urinary retention secondary to a suspected foreign object in his urethra. We review the diagnosis and management of self-inserted urethral foreign objects in men. Emergent treatment is necessary in patients with urethral foreign objects. Prompt radiologic studies should be obtained because immediate bladder access and drainage is mandatory, especially in patients presenting with urosepsis or urinary retention. Endoscopic removal is the management of choice.

Foreign Bodies↗

Intracranial sewing needle.

A 45-year-old patient was found to have an intracranial sewing needle, located in the left frontal lobe. The needle was detected incidentally after minor head trauma. The clinical and radiological findings suggested that it might have entered the brain through the anterior fontanelle.

Foreign Bodies↗