PubMed Health⌕ Search

Biomedical subjects

Michael V Pishko

Publications and source records attributed to Michael V Pishko.

At least 19 recordsLinked to original sources

Cell adhesion on nanofibrous polytetrafluoroethylene (nPTFE).

Here, we described the in vitro biocompatibility of a novel nanostructured surface composed of PTFE as a potential polymer for the prevention of adverse host reactions to implanted devices. The foreign body response is characterized at the tissue-material interface by several layers of macrophages and large multinucleated cells known as foreign body giant cells (FBGC), and a fibrous capsule. The nanofibers of nanofibrous PTFE (nPTFE) range in size from 20 to 30 nm in width and 3-4 mm in length. Glass surfaces coated with nPTFE (produced by jet-blowing of PTFE 601A) were tested under in vitro conditions to characterize the amount of protein adsorption, cell adhesion, and cell viability. We have shown that nPTFE adsorbs 495 +/- 100 ng of bovine serum albumin (BSA) per cm2. This level was considerably higher than planar PTFE, most likely due to the increase in hydrophobicity and available surface area, both a result of the nanoarchitecture. Endothelial cells and macrophages were used to determine the degree of cell adsorption on the surface of the nanostructured polymer. Both cell types were significantly more round and occupied less area on nPTFE as compared to tissue culture polystyrene (TCPS). Furthermore, a larger majority of the cells on the nPTFE were dead compared to TCPS, at dead-to-live ratios of 778 +/- 271 to 1 and 23 +/- 5.6 to 1, respectively. Since there was a high amount of cell death (due to either apoptosis or necrosis), and the foreign body response is a form of chronic inflammation, an 18 cytokine Luminex panel was performed on the supernatant from macrophages adherent on nPTFE and TCPS. As a positive control for inflammation, lipopolysaccharide (LPS) was added to macrophages on TCPS to estimate the maximum inflammation response of the macrophages. From the data presented with respect to IL-1, TNF-alpha, IFN-gamma, and IL-5, we concluded that nPTFE is nonimmunogenic and should not yield a huge inflammatory response in vivo, and cell death observed on the surface of nPTFE was likely due to apoptosis resulting from the inability of cells to spread on these surface. On the basis of the production of IL-1, IL-6, IL-4, and GM-CSF, we concluded that FBGC formation on nPTFE may be decreased as compared to materials known to elicit FBGC formation in vivo.

Adsorption↗

Microporated PEG spheres for fluorescent analyte detection.

Poly(ethylene glycol) (PEG) hydrogels have been used to encapsulate fluorescently labeled molecules in order to detect a variety of analytes. The hydrogels are designed with a mesh size that will retain the sensing elements while allowing for efficient diffusion of small analytes. Some sensing assays, however, require a conformational change or binding of large macromolecules, which may be sterically prohibited in a dense polymer matrix. A process of hydrogel microporation has been developed to create cavities within PEG microspheres to contain the assay components in solution. This arrangement provides improved motility for large sensing elements, while limiting leaching and increasing sensor lifetime. Three hydrogel compositions, 100% PEG, 50% PEG, and microporated 100% PEG, were used to create pH-sensitive microspheres that were tested for response time and stability. In order to assess motility, a second, more complex sensor, namely a FITC-dextran/TRITC-Con A glucose-specific assay was encapsulated within the microspheres.

Capsules↗

Macrophage uptake of core-shell nanoparticles surface modified with poly(ethylene glycol).

The in vitro uptake of core-shell nanoparticles encapsulated in a bio-macromolecular nanoshell assembled from multilayered polyelectrolytes was studied. Sulfate modified fluorescent polystyrene nanobeads (diameter 200 nm) were used as a solid core upon which charged multilayers of poly-l-lysine, chitosan, and heparin sulfate are electrostatically deposited utilizing a layer-by-layer (LbL) self-assembly process. The nanoshell composed of the multilayered polyelectrolytes was modified with poly(ethylene glycol) (PEG) of varying molecular weights (either MW 2000, 5000, or 20 000 Da) to form a hydrophilic and long-circulating nanoparticle. The assembly of the nanoshell was confirmed by zeta potential, transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS). The reversal in charge upon the deposition of alternating polyelectrolytes was observed by zeta potential measurements. The nanometer thickness of the nanoshell was confirmed by TEM. The presence of the (C-C-O)(n)() backbone in PEG at the surface of the nanoshell was confirmed by the increase in (C-O,N) peak area concentrations compared to (C-C) peak area, and these results were gathered from XPS. In vitro studies between suspension macrophages and core-shell nanoparticles were performed to determine how the hydrophilicity and the charge on the nanoshell can promote or reduce uptake. Results showed that after 24 h uptake was decreased 3-fold when PEGs of 2000 and 20 000 Da were chemisorbed to the nanoshell, as opposed to a nanoshell with either a positive or highly negative charge. Confocal microscopy aided in verifying that core-shell nanoparticles were internalized within the cell cytoplasm and were not attached to the cell surface. Protein adhesion studies with bovine serum albumin were performed to determine the relationship between surface charge and opsonization of core-shell nanoparticles. It was found that a hydrophilic surface with a low negative charge reduced protein adsorption and uptake. The in vitro uptake of macrophages and protein adsorption onto core-shell nanoparticles formed using layer-by-layer assembly has not been previously studied.

Adsorption↗

Fabrication of cell-containing hydrogel microstructures inside microfluidic devices that can be used as cell-based biosensors.

This paper describes microfluidic systems containing immobilized hydrogel-encapsulated mammalian cells that can be used as cell-based biosensors. Mammalian cells were encapsulated in three-dimensional poly(ethylene glycol)(PEG) hydrogel microstructures which were photolithographically polymerized in microfluidic devices and grown under static culture conditions. The encapsulated cells remained viable for a week and were able to carry out enzymatic reactions inside the microfluidic devices. Cytotoxicity assays proved that small molecular weight toxins such as sodium azide could easily diffuse into the hydrogel microstructures and kill the encapsulated cells, which resulted in decreased viability. Furthermore, heterogeneous hydrogel microstructures encapsulating two different phenotypes in discrete spatial locations were also successfully fabricated inside microchannels.

3T3 Cells↗

Multiphenotypic whole-cell sensor for viability screening.

Here, we describe the fabrication of whole mammalian cell biosensors for the optical monitoring of cell viability. Three phenotypes were examined for their response to the addition of two model chemotoxins: sodium hypochlorite and sodium azide, and one model biotoxin, concanavalin A. Two sensing platforms containing cells, hydrogel microspheres, or hydrogel arrays, were also explored. Step changes in viability in response to small doses of sodium hypochlorite were seen nearly instantaneously in all cell lines, in solution, microspheres, and microarrays. Linear detection of sodium azide by entrapped hepatocytes was 0-10 microM, whereas the linear detection range for macrophages and endothelial cells was 0-75 microM. Macrophages and hepatocytes have a greater sensitivity, as indicated by a 40% change in fluorescence over the linear range, whereas endothelial cells show only a 15% change in fluorescence over the linear range. Using photoreaction injection molding, we were also able to generate a multiphenotype sensor that enables the measurement of the toxic effect of 100 microg/mL concanavalin A on macrophages and hepatocytes, but not on endothelial cells.

Animals↗

Heat-stabilized phospholipid films: film characterization and the production of protein-resistant surfaces.

Phospholipid films have been shown in a number of studies to exhibit potential as nonfouling surfaces for biomaterial applications. However, the practical application of such films has been hindered by instability in aqueous solutions and significant detachment under mild shear stresses. Methods for stabilizing lipid films have been investigated, but to date require the presence of specific functional groups or chemical modification of the lipid molecule. In contrast to these methods, we present a process for heat-stabilization of lipid films. These heat-stabilized films have been shown to be able to withstand repeated rinsing without significant detachment. Phosphatidylcholine monolayers were formed on hydrophobic self-assembled monolayers using the liposome fusion method and stabilized at 80 degrees C. The films were characterized using Fourier transform infrared spectroscopy, ellipsometry, and atomic force microscopy and were shown to be defect free after repeated rinsing. Further experiments using a quartz crystal microbalance showed that the heat-stabilized lipid films were highly resistant to nonspecific protein adhesion and compared very favorably with poly(ethylene glycol)-coated surfaces under identical exposure conditions.

Adsorption↗

Encapsulation of enzymes within polymer spheres to create optical nanosensors for oxidative stress.

We describe the fabrication and characterization of poly(ethylene glycol) (PEG) hydrogel spheres containing the enzyme horseradish peroxidase (HRP) for application as optical nanosensors for hydrogen peroxide. HRP was encapsulated in PEG hydrogel spheres by reverse emulsion photopolymerization, yielding spheres with a size range from 250 to 350 nm. Encapsulated HRP activity and sensitivity to hydrogen peroxide were investigated by the Amplex Red assay based on the fluorescence response as a function of H2O2. These HRP-loaded spheres were then introduced to murine macrophages with Amplex Red in the culture media. After phagocytosis, the biocompatibility of spheres was determined by live cell staining using calcein AM (5 microM). The HRP-loaded PEG hydrogel spheres were activated (i.e., fluorescent oxidized Amplex Red produced within the spheres) by oxidative stresses such as exogenous H2O2 (100 microM) and lipopolysaccharide (1 microg/mL), which induced the production of endogenous peroxide inside macrophages. The results presented here indicate that after polymerization, the enzyme activity of HRP was still maintained and that using these HRP-containing nanospheres, peroxide production could be sensed locally within cells.

Animals↗

Competitive binding assay for glucose based on glycodendrimer-fluorophore conjugates.

A new fluorescent glucose assay has been created using Alexa Fluor 647-labeled concanavalin A (Con A) and a fourth-generation PAMAM Alexa Fluor 594-labeled glycodendrimer. This assay has been shown to have a large response to glucose within the biological range and to be capable of functioning within a polymer hydrogel. In this paper, the glucose response is shown to be a single fluorophore-based quenching reaction. Data showing that the sensor is fully reversible and specific through competitive binding between the dendrimer and glucose with Con A are presented. Overall, the assay is shown to have potential over the traditional dextran-based assay because it has a larger dynamic response to physiological glucose concentrations, incorporates longer wavelength dyes that improve signal penetration through dermal tissue, and provides an internal reference in the form of a nonreactive fluorescent label.

Binding, Competitive↗

Comparison of glycosphingolipids and antibodies as receptor molecules for ricin detection.

Glycosphingolipids (GSLs) have been shown to undergo strong interactions with a number of protein toxins, including potential bioterrorism agents such as ricin and botulinum neurotoxin. Characterization of this interaction in recent years has led to a number of studies where GSLs were used as the recognition molecules for biosensing applications. Here, we offer a comparison of quartz crystal microbalance (QCM) sensors for the detection of ricin using antibodies and the GSLs GM1 and asialoGM1, which have been shown to undergo strong interactions with ricin. The presence, orientation, and activity of the GSL and antibody films were confirmed using ellipsometry, Fourier transform infrared spectroscopy (FT-IR), and QCM. It was found that the GSLs offered more sensitive detection limits when directly compared with antibodies. Both GSLs had lower detection limits at 5 microg/mL, approximately 5 times lower than were found for antibodies (25 microg/mL), and their linear detection range extended to the highest concentrations tested (100 microg/mL), almost an order of magnitude beyond the saturation point for the antibody sensors. Potential sites for nonspecific adsorption were blocked using serum albumin without sacrificing toxin specificity.

Biosensing Techniques↗

A novel single-step fabrication technique to create heterogeneous poly(ethylene glycol) hydrogel microstructures containing multiple phenotypes of mammalian cells.

In this study, a novel method for the one-step fabrication of stacked hydrogel microstructures using a microfluidic mold is presented. The fabrication of these structures takes advantage of the laminar flow regime in microfluidic devices, limiting the mixing of polymer precursor solutions. To create multilayered hydrogel structures, microfluidic devices were rotated 90 degrees from the traditional xy axes and sealed with a cover slip. Two discreet fluidic regions form in the channels, resulting in the multilayered hydrogel upon UV polymerization. Multilayered patterned poly(ethylene glycol) hydrogel arrays (60 mum tall, 250 mum wide) containing fluorescent dyes, fluorescein isothiocyanate, and tetramethylrhodamine isothiocyanate were created for imaging purposes. Additionally, this method was used to generate hydrogel layers containing murine fibroblasts and macrophages. The cell adhesion promoter, RGD, was added to hydrogel precursor solution to enhance fibroblast cell spreading within the hydrogel matrix in one layer, but not the other. We were able to successfully generate patterns of hydrogels containing multiple phenotypes by using this technique.

Animals↗

Encapsulation of drug nanoparticles in self-assembled macromolecular nanoshells.

Layer-by-Layer (LbL) stepwise self-assembly of the polyelectrolytes poly(allylamine hydrochloride) and poly(styrenesulfonate) was used to create a macromolecular nanoshell around drug nanoparticles (approximately 150 nm in diameter). Dexamethasone, a steroid often used in conjugation with chemotherapy, was chosen as a model drug and was formulated into nanoparticles using a modified solvent-evaporation emulsification method. Measurement of the zeta potential (zeta-potential) after each polyelectrolyte layer was electrostatically added confirmed the successful addition of each layer. Additionally, data acquired from X-ray photon spectroscopy (XPS) indicated the presence of peaks representative of each physisorbed polyelectrolyte layer. Surface modification of the nanoshell was performed by covalently attaching poly(ethylene glycol) (PEG) with a molecular weight of 2000 to the outer surface of the nanoshell. Zeta potential measurements and XPS indicated the presence of PEG chains at the surface of the nanoshell. The polymeric nanoshell on the surface of the drug nanoparticle provides a template upon which surface modifications can be made to create a stealth or targeted drug delivery system.

Dexamethasone↗

Microreactor microfluidic systems with human microsomes and hepatocytes for use in metabolite studies.

In the area of drug discovery, high-speed synthesis has increased the number of drug candidates produced. These potential drugs need to be evaluated for their adsorption, distribution, metabolism, elimination, and toxicology (ADMET) properties as early in the drug development stage as possible. Previously, a potential drug's ADMET properties have been found out by using monolayer cell cultures and live animals. These methods can be costly, time-intensive, and impractical for screening the large amount of potential drugs created by combinatorial chemistry. A quick, small, inexpensive, and highly parallel device would be desirable to determine a drug candidate's properties (i.e., metabolism of the drug). Here we fabricate a microfluidic device entrapping human microsomes within poly(ethylene) glycol hydrogels thereby generating an in situ microreactor to assess a drug candidate's metabolic properties that can be coupled to analysis equipment. We show that microsomes can be entrapped without the loss of enzymatic activity during photopolymerization. Additionally, a microreactor utilizing hepatocytes was also created for comparison with the microsome microreactor.

Biological Assay↗

Attenuation of protein adsorption on static and oscillating magnetostrictive nanowires.

The research described here investigates the hypothesis that nanoarchitecture contained in a nanowire array is capable of attenuating the adverse host response generated when medical devices are implanted in the body. This adverse host response, or biofouling, generates an avascular fibrous mass transfer barrier between the device and the analyte of interest, disabling the implant if it is a sensor. Numerous studies have indicated that surface chemistry and architecture modulate the host response. These findings led us to hypothesize that nanostructured surfaces will inhibit the formation of an avascular fibrous capsule significantly. We are investigating whether arrays of oscillating magnetostrictive nanowires can prevent protein adsorption. Magnetostrictive nanowires were fabricated by electroplating a ferromagnetic metal alloy into the pores of a nanoporous alumina template. The ferromagnetic nanowires are made to oscillate by oscillating the magnetic field surrounding the wires. Radiolabeled bovine serum albumin, enzyme-linked immunosorbent assay (ELISA), and other protein assays were used to study protein adhesion on the nanowire arrays. These results display a reduced protein adsorption per surface area of static nanowires. Comparing the surfaces, 14-30% of the protein that absorbed on the flat surface adsorbed on the nanowires. Our contact angle measurements indicate that the attenuation of protein on the nanowire surface might be due to the increased hydrophilicity of the nanostructured surface compared to a flat surface of the same material. We oscillated the magnetostrictive wires by placing them in a 38 G 10 Hz oscillating magnetic field. The oscillating nanowires show a further reduction in protein adhesion where only 7-67% of the protein on the static wires was measured on the oscillating nanowires. By varying the viscosity of the fluid the nanowires are oscillated in, we determined that protein detachment is shear-stress modulated. We created a high shearing fluid with dextran, which reduced protein adsorption on the oscillating nanowires by 70% over nanowires oscillating in baseline viscosity fluid. Our preliminary studies strongly suggest that the architecture in the static nanowire arrays and the shear created by oscillating the nanowire arrays would attenuate the biofouling response in vivo.

Adsorption↗

Heat-stabilized glycosphingolipid films for biosensing applications.

We have investigated a means of producing thin, oriented lipid monolayers which are stable under repeated washing and which may be useful in biosensing or surface-coating applications. Phosphatidylcholine and the glycosphingolipid GM1 were used as representative lipids for this work. Initially, a mixed self-assembled monolayer of octanethiol and hexadecanethiol was produced on a gold surface. This hydrophobic monolayer was then brought into contact with a thin lipid film that had been assembled at the liquid/air interface of a solution, allowing the lipid to deposit on the gold surface through hydrophobic interactions. The lipid layer was then heated to cause intermingling of the fatty acid and alkanethiol chains and cooled to form a highly stable film which withstood repeated rinsing and solution exposure. Presence and stability of the film were confirmed via ellipsometry, Fourier transform infrared spectroscopy, and quartz crystal microbalance (QCM), with an average overall film thickness of approximately 3.5 nm. This method was then utilized to produce GM1 layers on gold-coated QCM crystals for affinity sensing trials with cholera toxin. For these sensing elements, the lower detection limit of cholera toxin was found to be approximately 0.5 microg/mL, with a logarithmic relationship between toxin concentration and frequency response spanning over several orders of magnitude. Potential sites for nonspecific adsorption were blocked using serum albumin without sacrificing toxin specificity.

Animals↗

Molding of hydrogel microstructures to create multiphenotype cell microarrays.

The fabrication of mammalian cell-containing poly(ethylene glycol) (PEG) hydrogel microstructures on glass and silicon substrates is described. Using photoreaction injection molding in poly(dimethylsiloxane) microfluidic channels, three-dimensional hydrogel microstructures encapsulating cells (fibroblasts, hepatocytes, macrophage) were fabricated with cells uniformly distributed to each hydrogel microstructure, and the number of cells in each hydrogel microstructure was controlled by changing the cell density of the precursor solution. PEG hydrogels were modified using an Arg-Gly-Asp (RGD) peptide sequence, with the incorporation of RGD into the hydrogel matrix promoting the spreading of encapsulated fibroblasts over a 24-h period in culture. Cells remained viable encapsulated in these hydrogel microstructures for a period in excess of 1 week in culture. Arrays of hydrogel microstructures encapsulating two or more phenotypes on a single substrate were successfully fabricated using multimicrofluidic channels, creating the potential for multiphenotype cell-based biosensors.

Journal Article↗

Poly(ethylene glycol) hydrogel microstructures encapsulating living cells.

We present an easy and effective method for the encapsulation of cells inside PEG-based hydrogel microstructures fabricated using photolithography. High-density arrays of three-dimensional microstructures were created on substrates using this method. Mammalian cells were encapsulated in cylindrical hydrogel microstructures of 600 and 50 micrometers in diameter or in cubic hydrogel structures in microfluidic channels. Reducing lateral dimension of the individual hydrogel microstructure to 50 micrometers allowed us to isolate 1-3 cells per microstructure. Viability assays demonstrated that cells remained viable inside these hydrogels after encapsulation for up to 7 days.

Animals↗

Cryopreservation of cell-containing poly(ethylene) glycol hydrogel microarrays.

Here we describe the fabrication and preservation of mammalian cell-containing hydrogel microarrays that have potential applications in drug screening and pathogen detection. Hydrogel microstructures containing murine fibroblasts were fabricated on silicon substrates and subjected to a "stage-down" freezing process. The percent viability of both immortal and primary embryonic murine fibroblast cells within the gels was determined at various stages in the freezing process, showing that cells entrapped in hydrogel microstructures remained viable throughout the process. When compared to immortalized adherent cultures subjected to the same freezing process, cells within hydrogel structures had higher cell viabilities at all stages during preservation. Finally, the necessity of using a cryoprotectant, dimethyl sulfoxide (DMSO), was investigated. Cells in hydrogels were cryopreserved with and without DMSO. The addition of DMSO altered cell viability after the freeze-thaw process, enhancing viability in an immortalized cell line and decreasing viability in a primary cell line.

3T3 Cells↗

Hepatocyte viability and protein expression within hydrogel microstructures.

Poly(ethylene) glycol (PEG) hydrogels have been successfully used to entrap mammalian cells for potential high throughput drug screening and biosensing applications. To determine the influence of PEG composition on the production of cellular protein, mammalian hepatocytes were maintained in PEG hydrogels for 7 days. Total cell viability, total protein production, and the production of two specific proteins, albumin and fibronectin, were monitored. Studies revealed that while PEG composition has no effect on cell viability, increasing amounts of PEG in the hydrogel decrease the amount of protein production by the cells after 7 days from 1.0 x 10(5) +/- 1.7 x 10(4) to 5.2 x 10(3) +/- 1.3 x 10(3) g accumulated protein/mL/million cells. Additionally, cells entrapped in PEG hydrogels produce greater amounts of protein than traditional monolayer culture (1.5 x 10(3) +/- 1.9 x 10(2) g accumulated protein/mL/million cells after 7 days). The addition of the synthetic peptide RGD to 10% PEG hydrogels altered the production of the proteins albumin and fibronectin. Hydrogels with the RGD sequence produced 287 +/- 27 ng/mL/million cells albumin after 7 days, an order of magnitude greater than monolayer cultures, whereas cells in hydrogels without the RGD sequence produced undetectable levels of albumin. Conversely, cells entrapped in 10% PEG hydrogels without the RGD sequence produced 1014 +/- 328 ng/mL/million cells fibronectin after 7 days, whereas 10% PEG hydrogels with the RGD sequence produced 200 +/- 58 ng/mL/million cells fibronectin after 7 days.

Animals↗