Comprehensive protein profiling by multiplexed capillary zone electrophoresis using cross-linked polyacrylamide coated capillaries.

We have recently developed a new process to create cross-linked polyacrylamide (CPA) coatings on capillary walls to suppress protein-wall interactions. Here, we demonstrate CPA-coated capillaries for high-efficiency (>2 x 10(6) plates per meter) protein separations by capillary zone electrophoresis (CZE). Because CPA virtually eliminates electroosmotic flow, positive and negative proteins cannot be analyzed in a single run. A "one-sample-two-separation" approach is developed to achieve a comprehensive protein analysis. High throughput is achieved through a multiplexed CZE system.

Acrylic Resins↗

Cholesterol modulated antibody binding in supported lipid membranes as determined by total internal reflectance microscopy on a microfabricated high-throughput glass chip.

A high-throughput microfabricated all-glass microchip, lipid biochip, was created and used to measure fluorescently tagged antibody binding to dinitrophenol (DNP) haptens in planar supported phospholipid/cholesterol lipid bilayers as a function of cholesterol-to-lipid molar ratio (X(CHOL)). Multiple parallel microchannels etched in the lipid biochip allowed simultaneous measurement of antibody binding to hapten-containing and hapten-free lipid bilayers, for a range of aqueous antibody concentrations. Specific and nonspecific antibody binding to the supported lipid bilayers was determined from the internally calibrated intensity of the surface fluorescence using total internal reflectance fluorescence (TIRF) microscopy. The TIRF intensity data of the specific antibody binding were fitted to the Langmuir isotherm and Hill equation models to determine the apparent dissociation constant K(d), the maximum fluorescence parameter F(infinity), and binding cooperativity n. As X(CHOL) increased from 0 to 0.50, K(d) exhibited a minimum of approximately 4 microM and n reached a maximum of approximately 2.2 at X(CHOL) approximately 0.20. However, F(infinity) appeared to be insensitive to the cholesterol content. The nonspecific binding fraction (NS), defined as the ratio of the TIRF intensity for hapten-free bilayers to that with hapten, showed a minimum of approximately 0.08 also at X(CHOL) approximately 0.20. The results suggest that cholesterol regulates the specific binding affinity and cooperativity, as well as suppresses nonspecific binding of aqueous antibody to a planar supported lipid bilayer surface at an optimal cholesterol content of X(CHOL) approximately 0.20. Interestingly, for X(CHOL) approximately 0.40, NS reached a maximum of approximately 0.57, suggesting significant packing defects in the lipid bilayer surface, possibly as a result of lipid domain formation as predicted by the lipid superlattice model. We conclude that cholesterol plays a significant role in regulating both specific and nonspecific antibody/antigen binding events on the lipid bilayer surface and that our lipid biochip represents a new and useful high-resolution microfluidic device for measuring lipid/protein surface binding activities in a parallel and high-throughput fashion.

Binding Sites, Antibody↗

From nanochannel-induced proton conduction enhancement to a nanochannel-based fuel cell.

The apparent proton conductivity inside a nanochannel can be enhanced by orders of magnitude due to the electric double layer overlap. A nanochannel filled with an acidic solution is thus a micro super proton conductor, and an array of such nanochannels forms an excellent proton conductive membrane. Taking advantage of this effect, a new class of proton exchange membrane is developed for micro fuel cell applications.

Electric Conductivity↗

Electric field-decoupled electroosmotic pump for microfluidic devices.

An electric field-free electroosmotic pump has been constructed and its pumping rate has been measured under various experimental conditions. The key component of the pump is an ion-exchange membrane grounding joint that serves two major functions: (i) to maintain fluid continuity between pump channels and microfluidic conduit and (ii) to ground the solution in the microfluidic channel at the joint through an external electrode, and hence to decouple the electric field applied to the pump channels from the rest of the microfluidic system. A theoretical model has been developed to calculate the pumping rates and its validity has been demonstrated.

Electricity↗

Separation and determination of ephedrine and pseudoephedrine by combination of flow injection with capillary electrophoresis.

A simple, rapid, and accurate method for the separation and determination of ephedrine and pseudoephedrine using direct UV absorbance detection has been developed by the combination of flow injection with capillary electrophoresis for the first time. The buffer solution used is a 40 mM borate solution with the pH adjusted to 9.5 using a 2 M NaOH solution. The linear calibration range is 50 to 1000 microg/mL (r = 0.9996) for both analytes, and the recoveries are 91.2-108.2% for ephedrine and 92.6-107.3% for pseudoephedrine, respectively. The relative standard deviation of the peak area is 1.6% for ephedrine and 1.3% for pseudoephedrine (n = 6) at a concentration of 500 microg/mL, respectively. A series of samples is injected repeatedly without current interruption and subsequent rinsing, and the contents of these two alkaloids in three marketed drugs and the medical plant, Ephedra sinica, are determined with satisfactory results by this method.

Calibration↗

On-line separation and preconcentration of silver ion on amidino-thiourea immobilized glass beads packing in flow injection analysis with atomic absorption spectrometric detection.

Amidino-thiourea immobilized glass beads (AGB I) were prepared and used as the microcolumn packing for the flow injection (FI) on-line separation and preconcentration of Ag(I) coupled with atomic absorption spectrometry (AAS) determination. Base metal ions and anions with a concentration of 2.0 mg mL(-1) had no interference with the determination of Ag(I). The limit of detection (LOD) of Ag(I) for a preconcentration time of 60 s with a sampling flow rate of 5.0 mL min(-1) for 40.0 ng mL(-1) of Ag(I) were 0.50 ng mL(-1) with the peak-height absorbance mode and 1.26 ng mL(-1) with the peak-area absorbance mode, respectively. The relative standard deviations (RSD) of 7 replicate determinations were 0.9% and 0.7% for the peak-height absorbance (H) and the peak-area absorbance (A), respectively. The method was successfully applied to the determination of Ag(I) in ore samples.

Journal Article↗

Preparation of poly(propyleneimine) dendrimer immobilized silica gel and its application as novel microcolumn packing for the on-line FI preconcentration and separation of platinum.

A G4.0 poly(propyleneimine) dendrimer immobilized silica gel (PPID-SG) was prepared with a divergent approach from gamma-aminopropyl silica gel (APSG) by repeating the reactions: 1) cyanoethylation of -NH2 and 2) reduction of -CN. Then it was successfully applied as the microcolumn packing for the on-line flow-injection (FI) preconcentration and separation and flame atomic absorption spectrometry (FAAS) determination of Pt. A limit of detection (LOD) of 0.014 microg/mL was obtained when 0.5 microg/mL Pt in chloride acid of PH = 3 was preconcentrated with a sample flow rate of 4.6 mL/min for 60s and the relative standard deviation (RSD) was 2.65%. Coexisting metal ions with concentration of 5.0 mg/mL and anion ions of 20.0 mg/ml have no interference in the determination of Pt. The proposed method was successfully applied to the determination of Pt in nickel alloy and anode slime samples.

Dendrimers↗

Replaceable cross-linked polyacrylamide for high performance separation of proteins.

An alternative sieving matrix, replaceable cross-linked polyacrylamide (rCPA), was developed for sodium dodecyl sulfate capillary gel electrophoresis (SDS-CGE) separation of proteins. This rCPA could be conveniently pressurized into separation capillaries under a pressure of 80 psi. SDS-CGE separations using this matrix generated high resolutions for a wide range (approximately 4 kD to approximately 300 kD) of proteins. When compared to the most frequently used sieving matrixes, the rCPA permitted the highest resolutions with comparable or increased separation speed for protein separations.

Acrylic Resins↗