PubMed Health⌕ Search

Biomedical subjects

R Izquierdo-Hornillos

Publications and source records attributed to R Izquierdo-Hornillos.

11 recordsLinked to original sources

High-performance liquid chromatographic separation of a complex mixture of diuretics using a micellar mobile phase of sodium dodecyl sulphate. Application to human urine samples.

A systematic optimization of the HPLC separation of a complex mixture containing 19 diuretics by micellar liquid chromatography using sodium dodecyl sulphate (SDS), a Hypersil (150 mmx3.0 mm I.D., 5 microm) C18 column, a flow-rate of 0.5 ml min(-1) and UV absorbance detection has been carried out. Several mobile phases consisting of SDS and organic modifiers such as acetonitrile, tetrahydrofuran, propanol, butanol or pentanol, and the pH adjusted to 3.2, were tested. The effect of the organic modifier and SDS concentration on the retention behavior and separation of the diuretics was investigated. A mobile phase containing 40 mM SDS and 4% tetrahydrofuran was finally selected. Under these conditions, 14 out of 19 diuretics were separated in about 31 min. A bivariant optimization method for the mobile phase SDS-tetrahydrofuran corroborated the above results. The effect of temperature on the retention was also studied, and 50 degrees C was selected. The optimized method was applied to human urine samples of subjects administered Diurex (tablets containing 20 mg of the active ingredient xipamide) without sample preparation.

Calibration↗

High-performance liquid chromatographic optimization study for the separation of natural and synthetic anabolic steroids. Application to urine and pharmaceutical samples.

An HPLC separation of a complex mixture containing 14 androgenic anabolic steroids (natural and synthetic) for screening purposes has been carried out. The applied optimization method involved the use of binary, ternary and quaternary mobile phases containing acetonitrile, methanol or tetrahydrofuran as organic modifiers. The effect of different reversed-phase packings and temperature on the separation using acetonitrile as organic modifier was studied. The optimum separation was achieved by using a water-acetonitrile (55:45, v:v) mobile phase and a Hypersil ODS (250 mm x 4.6 mm) 5 microm column (30 degrees C) in about 38 min, allowing the separation of 14 out of 14 compounds tested (when danazol is excluded, 13 out of 14 were separated in 23 min). Calibration graphs were obtained using bolasterone, methyltestosterone and canrenone as internal standards. Detection limits were in the range 0.012-0.11 microg ml(-1). The optimized separation was applied for monitoring the norethindrone acetate hydrolysis from tablets and to the analysis, after liquid-liquid extraction, of urine samples spiked with steroids.

Anabolic Agents↗

Optimization of the high-performance liquid chromatographic separation of a complex mixture containing urinary steroids, boldenone and bolasterone: application to urine samples.

An HPLC separation of a complex mixture containing 13 urinary anabolics and corticoids, and boldenone and bolasterone (synthetic anabolics) has been carried out. The applied optimization method involved the use of binary, ternary and quaternary mobile phases containing acetonitrile, methanol or tetrahydrofuran as organic modifiers. The effect of different reversed-phase packings and temperature on the separation was studied. The optimum separation was achieved by using a water-acetonitrile (60:40, v/v) mobile phase in reversed-phase HPLC at 30 degrees C, allowing the separation of all the analytes in about 24 min. Calibration graphs were obtained using bolasterone or methyltestosterone as internal standards. Detection limits were in the range 0.012-0.107 microg ml(-1). The optimized separation was applied to the analysis, after liquid-liquid extraction, of human urine samples spiked with steroids.

Adrenal Cortex Hormones↗

Optimization of separation of a complex mixture of natural and synthetic corticoids by micellar liquid chromatography using sodium dodecyl sulphate. Application to urine samples.

A systematic optimization of the separation of a mixture of corticoids by micellar liquid chromatography, using sodium dodecyl sulphate as surfactant, a Hypersil (250 mm x 3.2 mm I.D.) C18 column, a flow-rate of 0.5 ml min(-1), and UV absorbance detection at 245 nm has been carried out. Several mobile phases consisting of sodium dodecyl sulphate and different organic modifiers were tested of which tetrahydrofuran, PrOH and BuOH were finally selected. On the basis of analysis time, resolution and number of compounds separated, a mobile phase containing 36 mM sodium dodecyl sulphate and 1.91% butanol allowed the separation of thirteen corticoids out of sixteen in about 27 min. Under these conditions the optimal concentration of sodium dodecyl sulphate was found to be 36 mM. A bivariant optimization method for the mobile phase BuOH-sodium dodecyl sulphate corrobored these results. The effects of temperature, ionic strength and flow-rate effect have also been studied. The most important analytical figures of merit were assessed and compared with those obtained using conventional mobile phases. The optimized method was applied to human urine samples of subjects administered with Dezacor (tablets containing 30 mg of the active ingredient deflazacort) with and without sample preparation.

Adrenal Cortex Hormones↗

LC method development for ibuprophen and validation in different pharmaceuticals.

An isocratic LC method for the simultaneous determination of ibuprophen (IBU) and its degradation product (4-isobutylacetophenone) has been developed and validated for different pharmaceuticals (sachets, tablets and gels). The chromatographic separation was achieved with phosphoric acid solution (pH 3.2)-acetonitrile (50:50, v/v) as mobile phase, a Hypersil C18 column and UV detection at 254 nm. In all cases, sample preparation was required before HPLC analysis.

Anti-Inflammatory Agents, Non-Steroidal↗

Development and validation of a high-performance liquid chromatography method for the determination of cold relief ingredients in chewing gum.

An isocratic high-performance liquid chromatography (HPLC) method for the simultaneous determination of the active compounds paracetamol, pseudoephedrine and chlorpheniramine in chewing gum samples has been developed and validated. The method required a simple liquid-liquid extraction using n-hexane and a mixture of water-acetonitrile prior to HPLC analysis. The chromatographic separation was achieved with an aqueous solution containing hexylamine (pH 3)-acetonitrile as the mobile phase, a Spherisorb C18 column and UV detection at 220 nm. As an application, the proposed method has been used to evaluate the release into saliva of these compounds from samples under a controlled human chewing process.

Acetaminophen↗

The effect of different amines added to eluents as silanol masking agents on the chromatographic behavior of some diuretics in reversed-phase high-performance liquid chromatography using C18 packings.

A preliminary gradient separation in reversed-phase liquid chromatography of a mixture of 25 solutes (diuretics, probenecide, and atenolol) is carried out using several C18 columns and an aqueous phosphoric acid solution (pH 3.2)-acetonitrile mobile phase as a control. Using this separation, the chromatographic behavior of these solutes is studied using 11 water-soluble primary, secondary, and tertiary amine modifiers in the range of 0.7-7.5 mM and a Spherisorb C18 column. This study reveals the presence in the complex sample of two groups of solutes with positive (five typical solutes showed improvements in peak symmetry and retention) or negative responses using these amines as mobile phase modifiers. After experimentation in the presence of amines, these differences are related to solute structure. Hexylamine is found to be an effective masking agent of silanols because of its structure and small required concentration. On these bases, the silanophilic and hydrophobic character of typical solutes and several C18 packings are evaluated under isocratic elution and a relative effectiveness index for amines, and a method for their assessment is proposed. The role of the amine structure on solute retention and the importance of selecting amines of suitable hydrophobic character, molecular geometry, and concentration is discussed. A model of the formation and stabilization of the silanol-amine complex based on hydrophobic and ionic interactions is also proposed.

Amines↗

Simultaneous determination of cortisol and cortisone in urine by reversed-phase high-performance liquid chromatography. Clinical and doping control applications.

A reversed-phase high-performance liquid chromatography (HPLC) method for the simultaneous determination of cortisol and cortisone in human urine samples using methylprednisolone as the internal standard is described. The method involves the systematic use of isocratic mobile phases of water and methanol, acetonitrile or tetrahydrofuran and a reversed-phase Hypersil C18 column. A water-acetonitrile mixture used as the mobile phase proved to be the most adequate one for analyzing urine samples purified by solvent extraction. The proposed method is sensitive, reproducible and selective. It was applied to the determination of cortisol and cortisone in several human urine samples: healthy subjects, sportsmen before and/or after stress for doping control purposes, and patients with Cushing's syndrome.

Calibration↗

Extraction and high-performance liquid chromatographic separation of deflazacort and its metabolite 21-hydroxydeflazacort. Application to urine samples.

Two HPLC methods for the separation of a mixture of corticoids including the oxazolinic corticoid deflazacort and its metabolite 21-hydroxydeflazacort using different water-tetrahydrofuran mobile phases were developed. Both separations allowed the detection and determination of fifteen out of sixteen corticoids using different C18 columns. Extraction data for deflazacort and its metabolite using different extraction procedures are also reported. These separation conditions were applied to urine samples from two male volunteers administered Dezacor, with both doping control and clinical purposes.

Adrenal Cortex Hormones↗

Solvent and solid-phase extraction of natural and synthetic corticoids in human urine.

Optimization of the main variables that affect solvent and solid-phase extraction processes, using disposable C18 cartridges and the non-ionic polymeric resin Serdolit AD-2, of human urine containing natural and synthetic corticoids is described. The data were obtained from different HPLC separations of these compounds using calibration graphs obtained before and after extraction of these compounds. The procedures, including sample preconcentration, showed efficiencies over 90%. NaCl was used to avoid emulsion formation in solvent extraction. The results achieved using solvent and solid-phase extraction are discussed.

Adrenal Cortex Hormones↗

Optimization of the high-performance liquid chromatrographic separation of a mixture of natural and synthetic corticosteroids.

Systematic optimization of the HPLC separation of a mixture of natural and synthetic corticosteroids was carried out for screening purposes. The method involves binary, ternary or quaternary mixtures containing water, methanol, acetonitrile and tetrahydrofuran. It was possible to separate thirteen out of fourteen corticosteroids contained in a sample in about 26 min, with a 5-microns Hypersil-C18 (250 mm x 4.6 mm I.D.) column thermostated at 30 degrees C, using a mobile phase composed of water-tetrahydrofuran (72:28, v/v). This separation was not improved using other C8 or C18 columns. The effect of temperature on the separation of these compounds was also studied. Calibration graphs were established for each corticosteroid up to 8 micrograms/ml using indapamide as internal standard. The detection limits were in the range 0.02-0.14 ng. The optimized method was applied to urine samples spiked with corticosteroids and showed potential for future applications.

Acetonitriles↗