Advantages of parallel imaging in conjunction with hyperpolarized helium--a new approach to MRI of the lung.

Hyperpolarized helium (3He) gas MRI has the potential to assess pulmonary function. The non-equilibrium state of hyperpolarized 3He results in the continual depletion of the signal level over the course of excitations. Under non-equilibrium conditions the relationship between the signal-to-noise ratio (SNR) and the number of excitations significantly deviates from that established in the equilibrium state. In many circumstances the SNR increases or remains the same when the number of data acquisitions decreases. This provides a unique opportunity for performing parallel MRI in such a way that both the temporal and spatial resolution will increase without the conventional decrease in the SNR. In this study an analytical relationship between the SNR and the number of excitations for any flip angle was developed. Second, the point-spread function (PSF) was utilized to quantitatively demonstrate the unconventional SNR behavior for parallel imaging in hyperpolarized gas MRI. Third, a 24-channel (24ch) receive and two-channel (2ch) transmit phased-array system was developed to experimentally prove the theoretical predictions with 3He MRI. The in vivo experimental results prove that significant temporal resolution can be gained without the usual SNR loss in an equilibrium system, and that the entire lung can be scanned within one breath-hold (approximately 13 s) by applying parallel imaging to 3D data acquisition.

Administration, Inhalation↗

Lumped-element planar strip array (LPSA) for parallel MRI.

The recently introduced planar strip array (PSA) can significantly reduce scan times in parallel MRI by enabling the utilization of a large number of RF strip detectors that are inherently decoupled, and are tuned by adjusting the strip length to integer multiples of a quarter-wavelength (lambda/4) in the presence of a ground plane and dielectric substrate. In addition, the more explicit spatial information embedded in the phase of the signals from the strip array is advantageous (compared to loop arrays) for limiting aliasing artifacts in parallel MRI. However, losses in the detector as its natural resonance frequency approaches the Larmor frequency (where the wavelength is long at 1.5 T) may limit the signal-to-noise ratio (SNR) of the PSA. Moreover, the PSA's inherent lambda/4 structure severely limits our ability to adjust detector geometry to optimize the performance for a specific organ system, as is done with loop coils. In this study we replaced the dielectric substrate with discrete capacitors, which resulted in both SNR improvement and a tunable lumped-element PSA (LPSA) whose dimensions can be optimized within broad constraints, for a given region of interest (ROI) and MRI frequency. A detailed theoretical analysis of the LPSA is presented, including its equivalent circuit, electromagnetic fields, SNR, and g-factor maps for parallel MRI. Two different decoupling schemes for the LPSA are described. A four-element LPSA prototype was built to test the theory with quantitative measurements on images obtained with parallel and conventional acquisition schemes.

Equipment Design↗

Four-angle saturation transfer (FAST) method for measuring creatine kinase reaction rates in vivo.

A new fast method of measuring kinetic reaction rates for two-site chemical exchange is described. The method employs saturation transfer magnetic resonance spectroscopy (MRS) and acquisition of only four spectra under partially saturated, high signal-to-noise ratio (SNR) conditions. In two acquisitions one of the exchanging species is saturated; the other two employ a control saturation. Each pair of acquisitions is applied with two different flip angles, and the equilibrium magnetization, relaxation times, and reaction rates are calculated therefrom. This four-angle saturation transfer (FAST) method is validated theoretically using the Bloch equations modified for two-state chemical exchange. Potential errors in the rate measurements due to the effects of exchange are evaluated for creatine kinase (CK) metabolism modeled for skeletal and heart muscle, and are found to be < 5% for forward CK flux rates of 0.05 < or = k(f) < or = 1.0 s(-1), and up to a 90% depletion of phosphocreatine (PCr). The effect of too much or too little saturating irradiation on FAST appears to be comparable to that of the conventional saturation transfer method, although the relative performance deteriorates when spillover irradiation cuts the PCr signal by 50% or more. "FASTer" and " FASTest" protocols are introduced for dynamic CK studies wherein [PCr] and/or k(f) changes. These protocols permit the omission of one or two of the four acquisitions in repeat experiments, and the missing information is recreated from initial data via a new iterative algorithm. The FAST method is validated empirically in phosphorus ((31)P) MRS studies of human calf muscle at 1.5 T. FAST measurements of 10 normal volunteers yielded the same CK reaction rates measured by the conventional method (0.29 +/- 0.06 s(-1)) in the same subjects, but an average of seven times faster. Application of the FASTer algorithm to these data correctly restored missing information within seven iterations. Finally, the FAST method was combined with 1D spatially localized (31)P MRS in a study of six volunteers, yielding the same k(f) values independent of depth, in total acquisition times of 17-39 min. These timesaving FAST methods are enabling because they permit localized measurements of metabolic flux, which were previously impractical due to intolerably long scan times.

Algorithms↗

Coupling and decoupling theory and its application to the MRI phased array.

In classical MRI phased-array design, optimal coil overlapping is used to minimize coupling between nearest-neighbor coils, and low input impedance preamplifiers are used to isolate the relatively weak coupling between non-nearest neighbors. However, to make the complex sensitivities of phased-array coils sufficiently distinct in parallel spatially-encoded MRI, it is desirable to have no overlapping between coils. Also, if phased arrays are used as transmit coils in MRI, one can no longer rely on the low input impedance of the preamplifiers for decoupling. Here a coupling and decoupling theory is introduced to provide a better understanding of the relations between coupled and uncoupled signals in the MRI phased array, and to offer a new method for decoupling phased-array coils without overlapping the nearest coil pairs. The new decoupling method is based on the assumption that any n-element phased array can be decoupled by a 2n-port interface system between phased array and preamplifiers. The detailed analysis and the experimental results show that a four-port interface can be used to decouple a two-element phased array. Furthermore, the four-port interfaces can serve as building blocks to construct a 2n-port decoupling interface. This new method allows one to place the coil elements anywhere that could optimize parallel spatial encoding without concern for coupling between the coils. The method can also be used for phased-array transmit coils.

Equipment Design↗