PubMed Health⌕ Search

Biomedical subjects

S Balter

Publications and source records attributed to S Balter.

At least 19 recordsLinked to original sources

On the use of DICOM cine header information for optimisation: results from the 2002 European DIMOND cardiology survey.

The paper explores the level of information contained within the DICOM header in images from various cardiology systems. Data were obtained in the European DIMOND survey on image quality (Italy, Ireland, Belgium, Greece and Spain). Images from five standard diagnostic cardiology procedures carried out in six European hospitals have been analysed. DICOM header information was extracted to a database in order to analyse how it could help in the optimisation of the procedures. The level of data contained in the headers differs widely between cardiology systems. None of the X-ray systems in the 2002 survey archives the dosimetric data in the DICOM header. The mean number of runs per procedure ranges between 7.5 and 15.4 and the mean number of frames per procedure between 575 and 1417. Differences in kVp, mA, pulse time, distances and C-arm angulations are substantial and suggest that there exists a wide range for optimisation.

Cardiology↗

Monitoring over-the-counter medication sales for early detection of disease outbreaks--New York City.

INTRODUCTION: Over-the-counter (OTC) medications are frequently used during the initial phase of illness, and increases in their sales might serve as an early indicator of communitywide disease outbreaks. Since August 2002, the New York City (NYC) Department of Health and Mental Hygiene (DOHMH) has tracked OTC medication sales to enhance detection of natural and intentional infectious disease outbreaks. OBJECTIVES: This report describes the surveillance system and presents results from retrospective analyses and a comparison between citywide trends in OTC medication sales and emergency department (ED) visits. METHODS: Sales data transmitted daily to DOHMH are categorized into two groups: influenza-like illness (ILI), which includes cough and influenza medications, and gastrointestinal illness (GI), which includes major brand and generic antidiarrheals. Cyclical, linear regression models were used to identify significant (p<0.05) increases in the daily ratio of ILI to analgesics sales (analgesics are used as a denominator in the absence of total sales). Daily and weekly average ratios of GI to analgesic sales were analyzed. Citywide trends in OTC ILI and GI medication sales were compared with ED visits for fever/influenza and diarrhea syndromes. RESULTS: Citywide ILI drug sales were highest during annual influenza epidemics and elevated during spring and fall allergy seasons, similar to trends in the ED fever/influenza syndrome. ILI sales did not consistently provide earlier warning than the ED system of communitywide influenza. GI drug sales increased during the fall and peaked during early winter and after the blackout of August 2003. Unlike ED diarrheal visits, GI medication sales did not substantially increase during late winter (February-March). CONCLUSION: Citywide OTC medication sales can provide indications of communitywide illness, including annual influenza epidemics. Antidiarrheal medication sales were more sensitive to increases in GI caused by norovirus and influenza than illness caused by rotavirus. OTC medication sales can be considered as an adjunct syndromic surveillance system but might not be as sensitive as ED systems.

Commerce↗

New York City syndromic surveillance systems.

New York City's first syndromic surveillance systems were established in 1995 to detect outbreaks of waterborne illness. In 1998, daily monitoring of ambulance dispatch calls for influenza-like illness began. After the 2001 World Trade Center attacks, concern about biologic terrorism led to the development of surveillance systems to track chief complaints of patients reporting to emergency departments, over-the-counter and prescription pharmacy sales, and worker absenteeism. These systems have proved useful for detecting substantial citywide increases in common viral illnesses (e.g., influenza, norovirus, and rotavirus). However, the systems have not detected more contained outbreaks earlier than traditional surveillance. Future plans include monitoring school health and outpatient clinic visits, augmenting laboratory testing to confirm syndromic signals, and conducting evaluation studies to identify which of these systems will be continued for the long term.

Bioterrorism↗

A new tool for benchmarking cardiovascular fluoroscopes.

This article reports the status of a new cardiovascular fluoroscopy benchmarking phantom. A joint working group of the Society for Cardiac Angiography and Interventions (SCA&I) and the National Electrical Manufacturers Association (NEMA) developed the phantom. The device was adopted as NEMA standard XR 21-2000, "Characteristics of and Test Procedures for a Phantom to Benchmark Cardiac Fluoroscopic and Photographic Performance," in August 2000. The test ensemble includes imaging field geometry, spatial resolution, low-contrast iodine detectability, working thickness range, visibility of moving targets, and phantom entrance dose. The phantom tests systems under conditions simulating normal clinical use for fluoroscopically guided invasive and interventional procedures. Test procedures rely on trained human observers.

Benchmarking↗

A new tool for benchmarking cardiovascular fluoroscopes.

This paper reports the status of a new cardiovascular fluoroscopy benchmarking phantom. A joint working group of the Society for Cardiac Angiography and Interventions (SCAI) and the National Electrical Manufacturers Association (NEMA) developed the phantom. The device has been adopted as NEMA standard XR 21-2000, 'Characteristics of and Test Procedures for a Phantom to Benchmark Cardiac Fluoroscopic and Photographic Performance' in August 2000. The test ensemble includes imaging-field geometry, spatial resolution, low-contrast iodine detectability, working thickness range, motion unsharpness, and phantom entrance dose. The phantom tests systems under conditions simulating normal clinical use for fluoroscopically guided invasive and interventional procedures. Test procedures rely on trained human observers.

Cardiovascular Diseases↗

Stray radiation in the cardiac catheterisation laboratory.

Staff radiation risk is related to the radiation field in which individuals work. Traditional protective measures focus on reducing stochastic risk. However, deterministic injury to the operator's hands cannot always be ignored. The stray radiation field is almost totally attributable to scatter from the patient. Its relative intensity is greatest near the entry port of the useful beam into the patient. The entry port moves during the procedure as the operator selects various required projections. Therefore, the relative exposure rate at any particular location in the laboratory changes with the clinical projection. The absolute scatter intensity is also dependent on the size and strength of the useful beam. Operators may put their hands near or in the useful beam. Leaded surgical gloves provide some overall finger protection for scatter fields. However, because of automatic dose rate controls, these gloves often increase risk when the operator's hands are seen on the image monitor.

Cardiac Catheterization↗

Functional antibody activity elicited by fractional doses of Haemophilus influenzae type b conjugate vaccine (polyribosylribitol phosphate-tetanus toxoid conjugate).

We evaluated the functional activities of antibodies, serum bactericidal activity (SBA), and immunoglobulin G (IgG) antibody avidity indices, using sodium thiocyanate (NaSCN) elution, elicited after vaccination with fractional doses of the Haemophilus influenzae type b conjugate (polyribosylribitol phosphate [PRP] conjugated to tetanus toxoid [PRP-T]) vaccine. A cohort of 600 infants from the Dominican Republic were randomized to receive one of three regimens of the PRP-T vaccine at ages 2, 4, and 6 months: full doses (10 microg of PRP antigen), one-half doses (5.0 microg), and one-third doses (3.3 microg) (J. Fernandez et al., Am. J. Trop. Med. Hyg. 62:485-490, 2000). Sixty serum samples, collected at age 7 months, with > or =2.0 microg of anti-PRP IgG per ml were randomly selected for avidity determinations. Geometric mean IgG concentrations were 13, 14, and 17 microg/ml for infants who received the full-dose (n = 19), one-half-dose (n = 19), and one-third-dose (n = 22) regimens, respectively. SBA geometric mean titers (1/dilution) were 85.0, 82.0, and 76.1 in sera from infants receiving the full-, one-half-, and one-third-dose regimens, respectively. Avidity indices (mean +/- standard error weighted average of NaSCN molar concentration x serum dilution factor) were 71.9 +/- 9.4, 123.6 +/- 26.8, and 150.9 +/- 24.9 for the full-, one-half-, and one-third-dose regimens, respectively. Upon comparison, the only significant difference (P = 0.024) found was a greater avidity index for sera from infants receiving the one-third-dose regimen than for sera from infants receiving the the full-dose regimen. We conclude that fractional doses elicit similar functional antibody activities in infants with > or = 2 microg of anti-PRP IgG per ml, corresponding to 89, 90, and 97% of infants receiving three doses of either the full concentration or one-half or one-third of the labeled concentration, respectively. This approach offers an alternative strategy for the prevention of H. influenzae type b disease in countries with limited resources.

Antibodies, Bacterial↗

Prevention of Haemophilus influenzae type b colonization by vaccination: correlation with serum anti-capsular IgG concentration.

Concentrations of serum anti-Haemophilus influenzae type b (anti-Hib) capsular polysaccharide (CPS) >/=0.15 and >/=1.0 microgram/mL are widely used as surrogates for protection against invasive Hib disease. However, the relationship between serum anti-Hib CPS following immunization and protection against colonization is not known, making it difficult to evaluate new Hib vaccines or combination vaccines. In the Dominican Republic, nasopharyngeal swabs were collected from 546 9-month-old infants who had received Hib conjugate vaccine at ages 2, 4, and 6 months and from 600 unvaccinated infants of the same age. The prevalence of Hib colonization was lower among vaccinated infants than among unvaccinated infants (0.9% vs. 2.3%). Among vaccinated infants, protection against colonization was significantly correlated with anti-Hib CPS concentrations >/=5 microgram/mL 1 month following the third dose of vaccine. These results suggest that the concentration of serum anti-Hib CPS needed for protection against colonization is greater than that needed for protection for invasive disease.

Antibodies, Bacterial↗

Epidemic nephritis in Nova Serrana, Brazil.

BACKGROUND: Outbreaks of nephritis have been rare since the 1970s. From December, 1997, to July, 1998, 253 cases of acute nephritis were identified in Nova Serrana, Brazil. Seven patients required dialysis, and three patients died. We did a case-control study to investigate the cause of the outbreak. METHODS: Using a matched cluster design, we examined seven recent patients, their family members (n=23), and members of neighbourhood-matched control households (n=22). We subsequently interviewed 50 patients and 50 matched controls about exposure to various dairy products. We also cultured dairy foods and took udder-swab and milk samples from cows. FINDINGS: Throat cultures indicated that nephritis was associated with group C Streptococcus equi subspecies zooepidemicus, a cause of bovine mastitis. S. zooepidemicus was detected in four of seven case households (six of 30 people) and no control households (p=0.09). Patients were more likely than matched controls to have consumed a locally produced cheese called queijo fresco (matched odds ratio 2.1, p=0.05). The nephritis attack rate was 4.5 per 1000 in Nova Serrana but 18 per 1000 in the village Quilombo do Gaia (p=0.003). The largest supplier of unpasteurized queijo fresco was a farm in Quilombo do Gaia. S. zooepidemicus was not detected in food samples or in swabs collected from cows in August, 1998, although mastitis was evident among cows on the suspected farm. Throat cultures of the two women who prepared cheese on this farm yielded the outbreak strain of S. zooepidemicus. After the cheese was removed from the distribution system, no further cases were reported. INTERPRETATION: A large outbreak of glomerulonephritis was attributed to S. zooepidemicus in unpasteurised cheese. This outbreak highlights the dangers of consuming unpasteurized dairy products and need for global efforts to promote food safety.

Adolescent↗

Procedural costs of digital vs. analog archiving of diagnostic cardiac catheterizations.

The use of digital technology in the cardiac catheterization laboratory is expanding at a rapid pace. The cost-effectiveness of this new technology is yet to be proven. The aims of this study were to determine the direct cost differences of digital versus analog media (CDs) for the storage of diagnostic cardiac catheterizations and to explore the factors influencing these differences. Procedural costs of all diagnostic angiograms (n = 109), from three physicians, performed in an analog catheterization laboratory (room A) and a digital catheterization laboratory (room C) were compared during a 9-month period. The mean procedural cost was higher in room A than in room C ($1,102 vs. $1,087, P < 0.001). This cost difference was eliminated when recording media costs were excluded from analysis ($1,079 vs. $1,080, P = 0.931). Therefore, we conclude there is a procedural cost savings in a cardiac catheterization room that uses digital CDs versus cineangiogram film as the archival media. Cathet. Cardiovasc. Intervent. 49:246-250, 2000.

Cardiac Catheterization↗

Personnel exposure during gamma endovascular brachytherapy.

PURPOSE: The use of 192Ir brachytherapy for the treatment of in-stent restenosis of the coronary arteries has shown promising clinical results. This paper investigates the radiation exposure of catheterization laboratory staff associated with the performance of this procedure. METHODS AND MATERIALS: Cath lab staff were monitored using personal monitors (shielded against fluoroscopic x-rays) during the performance of eleven cases using nominal 10 GBq 192Ir sources. Staff positions in the lab were simultaneously tracked by video cameras. Direct measurements were also made using a survey meter. Treatments were administered in a conventional cardiac-catheterization-laboratory. RESULTS: The dosimeter readings were analyzed in combination with the radiation survey and time motion survey. Brachytherapy procedural times for the cardiologist, oncologist, physicist, and angiographic assistants were, respectively, 26 +/- 24, 401 +/- 132, 486 +/- 148, and 7 +/- 13 s per case (mean +/- standard deviation). Readings of the personnel monitors were low. Credible upper limits of the respective doses are estimated to be less than 10, 10, 7, and 5 microSv per procedure. Auxiliary shields reduced the dose to individuals located outside of the catheterization laboratory to less than 0.5 microSv per procedure. CONCLUSIONS: The average radiation dose received by laboratory personnel during a representative 192Ir endocoronary brachytherapy procedure is estimated to be less than 0.1% of the NCRP recommended annual radiation worker's Maximum Permissible Dose (1% of the general public's MPD). This level is justifiable as long as the use of 192Ir benefits patients by producing an improved clinical outcome relative to the use of a less penetrating radionuclide or the application of alternative therapies. Further optimization of the delivery procedure is expected to reduce staff dose.

Brachytherapy↗

Analysis of immunoreactivity to a Streptococcus equi subsp. zooepidemicus M-like protein To confirm an outbreak of poststreptococcal glomerulonephritis, and sequences of M-like proteins from isolates obtained from different host species.

The etiologic agent of a large 1998 outbreak of poststreptococcal acute glomerulonephritis (PSGN) in Nova Serrana, Brazil, was found likely to be a specific strain of Streptococcus equi subsp. zooepidemicus from contaminated cheese (S. Balter et al., Lancet 355:1776-1780, 2000). In the present study, we used a serologic screen for a known surface-exposed virulence factor to confirm the epidemiologic findings. Using primers flanking a previously characterized M-like protein gene (J. F. Timoney et al., Infect. Immun. 63:1440-1445, 1995), we amplified and sequenced the M-like protein (designated Szp5058) gene and found it to be identical among four independent acute-phase PSGN patient isolates. Convalescent-phase sera from 33 of 44 patients in the PSGN outbreak were found to contain antibodies highly reactive to a purified Szp5058 fusion protein, compared with 1 of 17 control sera (P < 0. 0001), suggesting that Szp5058 was expressed during infection and further implicating this strain as the cause of the PSGN outbreak. The predicted signal sequence and cell wall association motif of Szp5058 were highly conserved with the corresponding sequence from S. equi subsp. zooepidemicus SzpW60, while the predicted surface-exposed portions differed markedly between these two proteins. The 5' end of the szp5058 gene, including its variable region, was identical to the szp gene from another strain associated with a previous PSGN outbreak in England (M. Barham et al., Lancet i:945-948, 1983), and the corresponding szp sequence found from the Lancefield group C type strain isolated from a guinea pig. In addition, the hypervariable (HV) portion of szp5058 was identical to a previously published HV sequence from a horse isolate (J. A. Walker and J. F. Timoney, Am. J. Vet. Res. 59:1129-1133, 1998). Three other strains of S. equi subsp. zooepidemicus, including another strain previously associated with a PSGN outbreak, were each found to contain a distinct szp gene. Two of these szp genes had HV regions identical to szp regions from isolates recovered from different host species.

Amino Acid Sequence↗

Randomized trial of the immunogenicity of fractional dose regimens of PRP-T Haemophilus influenzae type b conjugate vaccine.

To assess the immunogenicity of more economical regimens of Haemophilus influenzae type b (Hib) conjugate vaccine, a randomized trial of fractional doses of polyribosylribitol phosphate-tetanus toxoid (PRP-T) Hib vaccine was undertaken in the Dominican Republic. Six hundred children were assigned to one of six regimens with PRP-T vaccine: full-dose, half-dose, and one-third-dose of Hib vaccine given separately or combined with diphtheria, tetanus, and pertussis (DTP) vaccine at ages 2, 4, and 6 months. Regimens that elicited antibody levels > 1.0 microg/mL in >70% of children and < or = 0.15 microg/mL in > 90% of children were considered acceptable. At 1 month post Dose 3, all regimens met the criteria for acceptable response. Among those who received Hib as a separate injection, geometric mean concentrations of anti-PRP bodies (GMCs) at age 1 month post Dose 3 were 11.2, 11.9, and 16.3 in the full, half, and one-third dose groups, respectively. Among those who received Hib and DTP combined, the GMCs were 6.4, 5.2, and 5.7 in the full-, half-, and one-third-dose groups respectively.

Antibodies, Bacterial↗

X-ray generation and control.

This article has focused on those aspects of X-ray generation that are of immediate concern to clinicians. Generators and tubes result from more than a century of basic technology, engineering design, and manufacturing know-how. How are the rotating anode bearings lubricated? Most tubes use ball bearings. They are exposed to temperatures ranging up to several hundred degrees Centigrade. They are expected to provide a reasonable lifetime while supporting the static and gyroscopic loads imposed by a heavy anode running at 10,000 rpm. This all happens in a vacuum. The answer is the use of silver alloy balls. Modern systems use many feedback circuits for precise control of X-ray output. Spatial, spectral, and temporal beam shaping are all active development areas. The goal is image optimization with minimum radiation risk to the patient. In exchange, the operator needs to tell the system something about the clinical requirements needed to manage the patient on the table. Other examples of the interaction of technical means and clinical requirements will be discussed in future articles.

Equipment Design↗

X-ray image intensifier.

The X-ray image intensifier converts an X-ray image into a bright visible light image. This enables image recording as well as viewing without dark adaptation. This tutorial describes the construction and function of the image intensifier tube and its associated optics.

Humans↗

Fluoroscopic and fluorographic cameras.

Cameras and display devices transfer images from the image intensifier to the observer's eye. Cinefilm cameras and video cameras are used together for the performance of cardiac angiography. The state of the art is evolving toward digital video-based systems. This tutorial introduces underlying technology.

Coronary Angiography↗