X-ray generation and control.

Abstract

This article has focused on those aspects of X-ray generation that are of immediate concern to clinicians. Generators and tubes result from more than a century of basic technology, engineering design, and manufacturing know-how. How are the rotating anode bearings lubricated? Most tubes use ball bearings. They are exposed to temperatures ranging up to several hundred degrees Centigrade. They are expected to provide a reasonable lifetime while supporting the static and gyroscopic loads imposed by a heavy anode running at 10,000 rpm. This all happens in a vacuum. The answer is the use of silver alloy balls. Modern systems use many feedback circuits for precise control of X-ray output. Spatial, spectral, and temporal beam shaping are all active development areas. The goal is image optimization with minimum radiation risk to the patient. In exchange, the operator needs to tell the system something about the clinical requirements needed to manage the patient on the table. Other examples of the interaction of technical means and clinical requirements will be discussed in future articles.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Balter. 1999. X-ray generation and control.. https://doi.org/10.1002/(sici)1522-726x(199901)46%3A1%3C92%3A%3Aaid-ccd23%3E3.0.co%3B2-b

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Microchip PCR.

Miniaturization of genetic tests has become an important goal. This review surveys the current progress towards the miniaturization of tests based on the polymerase chain reaction (PCR). It examines the different types of PCR microchip designs, fabrication methods,and the components of a microchip PCR device. It also discusses the problems attributable to surface chemistry of microchip components (inhibition of PCR), and the static and dynamic surface passivation strategies developed for the solution of these difficulties

Equipment Design↗

Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube.

OBJECTIVE: This study compared the recently introduced Microcuff endotracheal tube HVLP ICU featuring an ultrathin (7-microm) polyurethane cuff membrane with endotracheal tubes from different manufacturers regarding fluid leakage past the tube cuff. DESIGN: In vitro setup. MEASUREMENTS AND RESULTS: The following endotracheal tubes (ID 7.5 mm) were compared: Mallinckrodt HiLo, Microcuff HVLP ICU, Portex Profile Soft Seal, Rüsch Super Safety Clear, and Sheridan CF. A vertical PVC trachea model (ID 20 mm) was intubated, and cuffs were inflated to 10, 15, 20, 25, 30, and 60 cmH2O. Colored water (5 ml) was added to the top of the cuff. The amount of leaked fluid past the tube cuff within 5, 10, and 60 min was recorded. Experiments were performed four times using two examples of each tube brand. Fluid leakage past tube cuffs occurred in all conventional endotracheal tubes at cuff pressures from 10 to 60 cmH2O. In the Microcuff tube cuff pressure fluid leakage was observed within 10 min only at 10 cmH2O. Results with the Microcuff tube were significantly better than all other tube brands at cuff pressures of 10-30 cmH2O. CONCLUSIONS: Within the acceptable upper limit for tracheal cuff pressure (25-30 cmH2O) the Microcuff endotracheal tube was the only one of the tested tubes to prevent fluid leakage in our in vitro setup. In vivo studies are required to confirm these findings.

Equipment Design↗