PubMed Health⌕ Search

PubMed · 10097364

Zolpidem distribution in postmortem cases.

Abstract

Zolpidem is the prototype of a class of sedative hypnotic drugs that are derivatives of imidazopyridine and is sold in the United States under the trade name Ambien. Over a four-year period, zolpidem was identified in eight cases investigated by the Office of the Chief Medical Examiner, State of Maryland. Zolpidem was identified by gas chromatography-nitrogen-phosphorus detection (GC-NPD) following an alkaline extraction and was confirmed by full-scan electron impact gas chromatography/mass spectrometry. Zolpidem was quantitated by GC-NPD in all specimens received. Five of the cases presented were deaths due to drug intoxication. In three of these cases, zolpidem was an incidental finding because the drug fatalities resulted from other drugs. In the other two cases of drug intoxication, zolpidem was present in elevated concentrations and was a contributing, but not exclusive cause of the drug intoxication. The remaining three cases were deaths that were not caused by drugs. The blood zolpidem concentrations in these cases were therapeutic (0.28, 0.12 and 0.19 mg/L, respectively). In six of the eight cases where both blood and urine were analyzed, the blood concentration was higher than the urine concentration. The distribution of zolpidem into the liver and kidney failed to identify any sequestration of the drug into either specimen.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Levine, S C Wu, J E Smialek. 1999. Zolpidem distribution in postmortem cases.. https://pubmed.ncbi.nlm.nih.gov/10097364/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stereointegrity of thalidomide: gas-chromatographic determination of the enantiomerization barrier.

Enantioselective chromatographic methods, representing the most commonly used techniques for the determination of enantiomeric ratios, can also be used for the evaluation of stereochemical integrity. In the present study, two chromatographic methods, dynamic gas chromatography (DGC) and stopped-flow gas chromatography (SFGC) were used to determine the enantiomerization barrier of thalidomide. In the presence of a chiral stationary phase (CSP), the enantiomers of thalidomide produced characteristic elution profiles exhibiting plateaus and/or peak broadening which were observed between 190 and 220 degrees C in DGC. To obtain the enantiomerization barrier of thalidomide from experimental data, the fast and efficient simulation program ChromWin was used to simulate the elution profiles and obtain kinetic activation parameters. From temperature-dependent measurements the rate constants k(1) and k(-1) and the kinetic activation parameters DeltaG#, DeltaH# and DeltaS# of the enantiomerization of thalidomide were obtained by DGC. The enantiomerization barrier DeltaG# was determined to be 154+/-2 kJ/mol with DGC and 150+/-3 kJ/mol with the sfGC technique at 200 degrees C, respectively. The concept of the retention increment R' has been applied to separate the enantiomerization barrier of thalidomide in the dissolved and complexed state of the CSP.

Chromatography, Gas↗

Comparison and evaluation of copper complex-containing siloxane polymers as stationary phases for capillary gas chromatography.

Two metallomesogenic polymers. P-C11CuC18 and P-C11CuC12 consisting of flexible aliphatic side chains with copper carboxylate complexes have been synthesized on the basis of addition reactions with polysiloxane. The applicability of the prepared columns to the analysis of phthalate esters that are of environmental concern was assessed. For preparation of the capillary column with its wall coated with the metallomesogenic polymer, both static and dynamic methods were employed. Factors affecting the retention and the sample selectivity on both columns were examined. A better separation of phthalates was achieved with P-C11CuC18 than P-C11CuC12. The former phase showed a higher solute-solvent interaction than the latter. With static coating, the wall-coated P-C11CuC18 capillary column (15 m x 250 microm I.D.) showed that the baseline separation of all 14 phthalates could be achieved within 38 min with high reproducibility. The calibration graphs for phthalate ester determination were linear over the range of 10-625 microg ml(-1). The mass detection limits were lower than the ng range based on three times the standard deviation of seven measurements of the lowest peak that could be detected.

Chromatography, Gas↗

Quantitative comparison of performance of isothermal and temperature-programmed gas chromatography.

As a basic metric of separation for comparing isothermal and temperature-programmed GC (gas chromatography), we used the separation measure. S (defined elsewhere). We used this metric as both a measure of separation of any two peaks, and a measure of separation capacity of arbitrary intervals where peaks can potentially exist. We derived several formulae for calculation of S for any pair of peaks regardless of their shape and the distance from each other in isothermal and temperature-programmed GC. The formulae for isothermal GC can be viewed as generalizations of previously known expressions while, in the case of temperature-programmed GC, no equivalents for the new formulae were previously known from the literature. In all formulae for S. we identified similar key component-metrics (solute separability, intrinsic efficiency of separation, specific separation measure, separation power) that helped us to identify and better understand the key factors affecting the separation process. These metrics also facilitated the quantitative comparison of separation capacities and analysis times in isothermal and temperature-programmed GC. Some of these metrics can be useful beyond GC. In the case of GC, we have shown that, if the same complex mixture was analyzed by the same column, and the same separation requirements were used then isothermal analysis can separate more peaks than its temperature-programmed counterpart can. Unfortunately, this advantage comes at the cost of prohibitively longer isothermal analysis time. The latter is a well know fact. Here, however, we provided a quantitative comparison. In a specific example, we have shown that a single-ramp temperature program with a typical heating rate yields about 25% fewer peaks than the number of peaks available from isothermal analysis of the same mixture using the same column. However, that isothermal analysis would last 1000 times longer than its temperature-programmed counterpart. Using twice as longer column in the case of a temperature-programmed analysis, allows one to recover the 25% disadvantage in the number of separated peaks, while still retaining a 500-fold advantage in the speed of analysis.

Chromatography, Gas↗