Abstract

This article describes a method for fabricating an auricular prosthesis. This procedure uses the contours of the soft tissue surface from computerized tomography scans to fabricate a computer-generated, side-inverted 3-dimensional soft tissue model from a solid block of polyurethane using an Endoplan milling machine. The resultant 3-dimensional soft tissue model can then be used as the basis for a wax sculpture. This procedure facilitates the planning of the prosthesis; symmetrical modeling, especially for large, hemifacial defects; and the impression, which can be made on the model itself.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Penkner, G Santler, W Mayer, G Pierer, M Lorenzoni. 1999. Fabricating auricular prostheses using three-dimensional soft tissue models.. https://doi.org/10.1016/s0022-3913(99)70038-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of chitosan and polycarbophil on permeation of a model hydrophilic drug into the urinary bladder wall.

Influence of dispersions of mucoadhesive polymers chitosan and polycarbophil on permeability properties of urinary bladder was investigated in vitro on isolated porcine urinary bladder. Pipemidic acid as a model hydrophilic drug was used. Its distribution in the bladder wall was determined from actual tissue concentrations by a method based on sectioning of frozen tissue and extraction of tissue slices. Pipemidic acid tissue concentration versus tissue depth profiles were evaluated by a diffusion model assuming constant diffusion coefficient. Increase in bladder wall permeability was observed in the presence of both polymers. Apparent permeability (mean+/-S.D.) of urinary bladder wall was increased 2.7+/-2.9 and 2.8+/-2.0 times for chitosan, and 2.3+/-2.0 and 4.3+/-4.2 times for polycarbophil at 0.5 and 1.0%, w/v polymer concentration, respectively. This increase is a consequence of the increased permeability of urothelium. These findings support investigations on application of chitosan and polycarbophil in development of mucoadhesive intravesical drug delivery systems. Experimental model may be applied to evaluate the results of experiments with drugs used in intravesical therapy.

Acrylic Resins↗

Using bifunctional polymers presenting vancomycin and fluorescein groups to direct anti-fluorescein antibodies to self-assembled monolayers presenting d-alanine-d-alanine groups.

This paper describes the synthesis of bifunctional polyacrylamides containing pendant vancomycin (Van) and fluorescein groups, and the use of these polymers to direct antibodies against fluorescein to self-assembled monolayers (SAMs) presenting d-alanine-d-alanine (dAdA) groups. These polymers bind biospecifically to these SAMs via interactions between the dAdA and Van groups and serve as a molecular bridge between the anti-fluorescein antibodies and the SAM. The binding events were characterized using surface plasmon resonance spectroscopy and fluorescence microscopy. The paper demonstrates that polyvalent, biospecific, noncovalent interactions between a polymer and a surface can be used to tailor the properties of the surface in molecular recognition. It also represents a first step toward the design of polymers that direct arbitrarily chosen antibodies to the surfaces of cells.

Acrylic Resins↗

Flow control valves for analytical microfluidic chips without mechanical parts based on thermally responsive monolithic polymers.

Monolithic plugs of poly(N-isopropylacrylamide) cross-linked with 5% methylenebisacrylamide have been prepared by photoinitiated polymerization within the channel of a microfluidic device. The volume change associated with the polymer phase transition at its lower critical solution temperature of 32 degrees C allows both the rapid swelling and the deswelling of the monoliths enabling the polymer to close or open the channel as it functions as a nonmechanical valve. Thermoelectric elements capable of changing the temperature of the system between 17 and 57 degrees C were used to actuate the valve. Flow through the device was monitored by fluorescence measurements via the laser-triggered photobleaching of a dye contained in the liquid phase. Photobleaching occurs quickly once the flow is stopped, and the time required to open and close the valve was 3.5 and 5.0 s, respectively. No changes in function were observed even after 120 open-close cycles. Although the 2-mm-long valve was prepared from a polymerization mixture consisting of only a 5% aqueous solution of monomers, it resists pressures of up to 1.38 MPa (200 psi) without observable structural damage.

Acrylic Resins↗