Resolution optimisation in micellar electrokinetic chromatography using empirical models.

Abstract

Theoretical and empirical models can be used to model the migration or separation characteristics in micellar electrokinetic chromatography in order to optimise the resolution. In this paper only empirical models were used, because it is easier and more straightforward to obtain these models. Several empirical approaches for the optimisation of the resolution were compared in order to determine which response should be modelled preferably. The use of models of the effective mobility in combination with average plate numbers proved to be the most suitable approach to optimisation of the resolution, because the relative prediction errors of the models of the effective mobility were a factor of 2-4 smaller than the relative prediction errors of the models of the apparent mobility. Moreover for the least separated peak pair the resolutions based on the models of the apparent and effective mobility showed relative prediction errors that were approximately a factor of 2 smaller than the relative prediction errors of the resolutions based on the models of the resolution and separation factor. The predictions of the separation factor based on the different models generally showed lower prediction errors than the predictions of the corresponding resolutions. Although the relative prediction errors were large, particularly for closely migrating compounds, the empirical approach will probably lead to the optimum separation buffer composition.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P V van Zomeren, M J Hilhorst, P M Coenegracht, G J de Jong. 2000-01-21. Resolution optimisation in micellar electrokinetic chromatography using empirical models.. https://doi.org/10.1016/s0021-9673(99)01150-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Recent progress in the use of ionic polymers as pseudostationary phases for EKC.

This review concerns the introduction, characterization, and application of polymeric pseudostationary phases (PSPs) for EKC since 2004. Achiral and chiral polymers and separations are reviewed, as is the application of polymeric PSPs for the combination of EKC with mass spectrometric detection.

Chromatography, Micellar Electrokinetic Capillary↗

MEKC: an update focusing on practical aspects.

This paper reviews recent methodological and instrumental advances in MEKC. Improvements in sensitivity arising from the use of on-line sample concentration (sweeping, stacking, and combination of both protocols) and derivatization (in-capillary reactions and coupling with flow-injection systems) and improvements in resolution obtained by changing the composition of the BGE (e.g., with organic modifiers, ionic liquids, nonionic and zwitterionic surfactants, mixed micelles, and vesicles) or using coated capillaries are discussed in detail. In addition, MS and LIF spectroscopy are examined in relation to their advantages and restrictions as applied to MEKC analysis. Some thoughts on potential future directions are also expressed.

Chromatography, Micellar Electrokinetic Capillary↗

Comparison of migration models for acidic solutes in micellar electrokinetic chromatography.

The validity of two models that explain the migration of ionisable solutes in micellar electrokinetic chromatography (MEKC), mobility model and retention factor model, has been tested. For this purpose, the mobility (mu) and retention factor (k) of a set of 10 phenolic compounds with different hydrophobicity and pKa values have been determined for several sodium dodecyl sulphate (SDS) concentrations and pH values, and fitted to the models. Results show that in general the retention factor model explains better the retention of ionisable solutes, although for hydrophilic compounds at low SDS concentration, mobility model can give better fits. The different drawbacks pointed out by several authors in relation to both models have been checked, and a deep evaluation of each one has been done. As a result we have observed that, while in the retention factor model the variation of k with pH and [SDS] always follows the same trend, the variation of mu with these variables mainly depends on the value of the binding constant of the neutral form of the solutes to the micelles, KHA(m), which plays a critical role in the fit of the mobility model. Also we provide rules and advices to set up the experimental conditions to apply each model to a particular solute.

Chromatography, Micellar Electrokinetic Capillary↗