Complications with permanent endocardial electrode systems.

Abstract

The different complications of endocardial electrode systems in 185 patients during the last seven years are discussed. The surgical technique for the now routinely used cephalic route is described. The choice of anaesthesia is discussed. In the last 39 implantations there have not been any displacements or retractions. Of the total number of patients only 3 required replacement of endocardial by myocardial electrodes. This was caused by unstable position and high stimulation threshold. Fracture of the electrode occurred in 4 cases. Stimulation of the diaphragm occurred in 10%, displacement and retraction of the electrodes in 6,5% and heart penetration or perforation in 3,8% of the patients. There was one death from cardiac tamponade due to electrode perforation of the right ventricle. One case had irreversible brain damage due to prolonged asystole during pulse generator replacement. Unimportant wound infections and haematomas occurred in 5 patients and phlebitis in 3 patients. More or less serious electrode complications have been seen in 56 of the 185 patients, 18 patients having more than one complication.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

O J Ohm, L Segadal, D W Skagen. 1976. Complications with permanent endocardial electrode systems.. https://doi.org/10.1111/j.0954-6820.1976.tb08373.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The development of a multichannel electrode array for retinal prostheses.

The development of a multielectrode array is the key issue for retinal prostheses. We developed a 10 x 10 platinum electrode array that consists of an 8-microm polyimide layer sandwiched between 5-microm polymonochloro-para-xylylene (parylene-C) layers. Each electrode was formed as a 30-microm-high bump by Pt/Au double-layer electroplating. We estimated the charge delivery capability (CDC) of the electrode by measuring the CDCs of two-channel electrode arrays. The dimensions of each electrode of the two-channel array were the same as those of each electrode formed on the 10 x 10 array. The results suggest that for cathodic-first (CF) pulses, 80% of electrodes surpassed our development target of 318 microC/cm2, which corresponds to the charge density of pulses of 500 micros duration and 200 microA amplitude for a 200-microm-diameter planar electrode.

Electrodes, Implanted↗

Improved version of the printed circuit board (PCB) modular multi-channel microdrive for extracellular electrophysiological recordings.

The modular multi-channel PCB microdrive was described some years ago, since then several improvements were introduced while using these drives. Utilizing several years of experience with the original PCB microdrive we redesigned it to improve its stability and usability. The application of the printed circuit board technology and the extensive use of flexible fused silica capillaries for fabrication of the microdrive are described in detail. The improved design led to a low cost and light-weight multi-channel microdrive with outstanding modularity for extracellular field, single unit or multiunit tetrode recording up to 64/128 channels.

Electrodes, Implanted↗