PubMed Health⌕ Search

PubMed · 11037013

Expert physician recommendations and current practice patterns for evaluating and treating men with osteoporotic hip fracture.

Abstract

OBJECTIVES: To develop recommendations for the evaluation and the treatment of men with osteoporotic hip fracture from expert publications in the field of male osteoporosis, and to define the current practice patterns in a tertiary care VA Medical Center in Durham, North Carolina. DESIGN: Survey research; a retrospective cohort study. SETTING: Tertiary care VA Medical Center in Durham, North Carolina. PARTICIPANTS: (1) US physicians who published on the subject of male osteoporosis in the peer-reviewed literature between 1993 and 1997 identified by MEDLINE database search. (2) All 119 men admitted to the Durham VA Medical Center with ICD9 code for hip fracture between 1994 and 1998. OUTCOME MEASURES: (1) Osteoporosis evaluation and treatment recommendations of published physicians obtained by survey instrument. (2) Actual osteoporosis evaluation completed and therapy prescribed during index hospitalization in a cohort of men with hip fractures, determined by chart and database review. RESULTS: (1) Forty-three physician-researchers were surveyed with an 84% response rate. For an osteoporosis evaluation, 89% of respondents recommended measuring serum testosterone, 85% serum calcium, 75% 25-OH vitamin D levels, 73% myeloma screen, and 61% serum thyroid-stimulating hormone (TSH). Dual Energy X-ray Absorptiometry would be obtained by 92%. More than 70% recommended calcium, vitamin D, and bisphosphonates for men with a normal metabolic evaluation, and 60% suggested weight-bearing exercise. (2) In the cohort of men admitted with hip fractures, 50% had a serum calcium level and 3% had a serum TSH level measured. Vitamin D was prescribed to 25% of patients in the form of a multivitamin, and 4% received calcium. There was no bisphosphonate, testosterone, or calcitonin use. CONCLUSIONS: Physicians who have published on osteoporosis recommended metabolic evaluation and osteoporosis therapy after hip fracture. Only minimal evaluation and treatment occurred in a cohort of men with osteoporotic hip fractures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Colón-Emeric, L Yballe, R Sloane, C F Pieper, K W Lyles. 2000. Expert physician recommendations and current practice patterns for evaluating and treating men with osteoporotic hip fracture.. https://doi.org/10.1111/j.1532-5415.2000.tb02599.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗