PubMed Health⌕ Search

PubMed · 11314130

Interface between titanium miniplate/screw and human calvaria.

Abstract

This study demonstrates interfacial changes of titanium miniplate/screw with normal calvaria and nonvascularized calvarial bone graft ensued from craniectomy in a 53-year-old female. In 18 months after operation, a right parietal bone containing an L-shaped miniplate with screws, 5 mm long and 2 mm in external diameter, was harvested, fixed, and embedded in methylmetacrylate. Fifteen micrometer thick sections were made by an EXAKT cutting-grinding system (Exakt Company, Hamburg, Germany), and reviewed under the bright field light microscope. The mean of the bone-contacting surface ratio (BCSR) in six screwed bone was 64.1%; 69.3% in normal bone, and 60.4% in grafted bone. The trabecular bone areas in 10 x 5 mm (50 mm2) rectangular area of diploe surrounding the screws was 43.02 mm2; 45.25 mm2 in normal calvaria; and 41.82 mm2 in grafted bone. The mean Ca/P peak-height ratio of the plated and screwed calvaria was 1.47 in a 9 mm wide zone around each screw; 1.37 in normal calvaria; and 1.51 in grafted calvaria. We concede that the effect of direct contact of titanium with screws onto the bone is as much as an osseous integration (osseointegration).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Hwang, J M Schmitt, J O Hollinger. 2000. Interface between titanium miniplate/screw and human calvaria.. https://doi.org/10.1097/00001665-200011020-00015

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stacked plating for metadiaphyseal fractures of the distal radius: a technique report.

Combined injuries of the distal radius and shaft are rare, are usually caused by high energy, and pose a surgical dilemma. Surgical tactics and implants that are routinely used either for isolated fractures of the distal radius or for fractures of the radial shaft are often not applicable for this combined injury. We describe a technique of dual-stacked plating for these metadiaphyseal fractures and its use in two patients.

Bone Plates↗

Plate fixation of olecranon osteotomies.

The management of intra-articular distal humeral fractures remains a difficult surgical problem. Although an olecranon osteotomy provides excellent exposure for management of these fractures, a number of complications can occur after the creation and repair of the osteotomy including nonunion, malunion, hardware failure, and pain secondary to prominent hardware. In an effort to reduce the incidence of these complications, the senior authors now use contoured 3.5 mm reconstruction plates for the fixation of their apex-distal chevron olecranon osteotomies. Two surgeons at a single institution used this technique of exposure on a series of 17 consecutive patients with intra-articular distal humerus fractures between 1996 and 1999. In this series, all osteotomies united. There was one complication related specifically to the osteotomy: one of the screws in the plate penetrated the proximal radioulnar joint, interfering with forearm rotation; a second procedure was required to shorten the screw. Only one of the 17 patients requested plate removal during the 32 month (average) follow-up period. Plate fixation of olecranon osteotomies using a 3.5 mm reconstruction plate provides a construct with predictable healing and few complications. The overall results using this technique are comparable with other reported methods in the literature.

Bone Plates↗