Inhalation toxicology.

Abstract

Two kinds of problems associated with developing standardized procedures for the safety evaluation of new compounds are identified. The first of these is the question of the desirability of using such standard methods. It is concluded that a basic set of procedures is to be recommended, but this should be supplemented with special tests as may be indicated. The second problem is connected with the technical difficulties of any given type of assay and is normally dealt with in terms of the state of the art at the time. Assays by the inhalation route tend to be custom designed and do not follow standard protocols. One of the causes of this situation is the propensity of individual investigators to design de novo the equipment used to effect exposure of animals to airborne substances. Second, some confusion exists because investigators do not always appreciate that the concentration-time product is not the same as the true dose received by the exposed subjects and this may lead to anomalies when dose-response relationships are being characterized. It is suggested that interlaboratory studies be undertaken to ascertain the variability that might be expected in independent assays of inhalation toxicity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H N MacFarland. 1975. Inhalation toxicology.. https://pubmed.ncbi.nlm.nih.gov/1150607/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Prediction and assessment of flammability hazards associated with metered-dose inhalers containing flammable propellants.

Several potential replacements for chlorofluorocarbons (CFCs) in metered-dose inhalers (MDIs) are flammable. The flammability hazard associated with their use was assessed using a range of MDIs containing 0-100% (w/w) n-butane (flammable) in HFC-134a (non-flammable) fitted with either 25-, 63-, or 100-microliters metering valves or continuous valves. In flame projection tests each MDI was fired horizontally into a flame, and the ignited flume length emitted from the MDI was measured. Flame projections of greater than or equal to 60 cm were produced by all formulations fitted with continuous valves which contained greater than or equal to 40% (w/w) n-butane in HFC-134a. Using metering valves the maximum flame projection obtained was 30 cm. This was observed with a formulation containing 90% (w/w) n-butane in HFC-134a and a 100-microliters valve. For a particular formulation, smaller metering valves produced shorter flame projections. Because many MDIs are used in conjunction with extension devices, the likelihood of accidental propellant vapor ignition was determined in Nebuhaler and Inspirease reservoirs and a Breathancer spacer. Ignition was predictable based on propellant composition, metered volume, number of actuations, and spacer capacity. Calculated n-butane concentrations in excess of the lower flammability limit [LFL; 1.9% (v/v)] but below the upper flammability limit [UFL; 8.5% (v/v)] were usually predictive of flammability following ignition by a glowing nichrome wire mounted inside the extension device. No ignition was predicted or observed following one or two 25-microliters actuations of 100% n-butane into large volume Nebuhaler (750 ml) or Inspirease (660 ml) devices.(ABSTRACT TRUNCATED AT 250 WORDS)

Aerosol Propellants

Volatile substance abuse.

Volatile substance abuse has been reported in the literature over the past 20 years or so, and has apparently increased as countries have become more industrialised. This review attempts to clarify trends in volatile substance abuse, problems associated with this behaviour and possible solutions. Data sources included a Medline Search on volatile substance abuse over the last five years, Commonwealth publications, recent State and Territory inhouse publications, three research monographs from the National Institute on Drug Abuse (NIDA) and an article library from the author's workplace. Some 250 articles and monographs were identified, reviewed and categorised into sections relating to epidemiology (including mortality), physiological effects and responses to the problem. Articles were used for reference where they reflected the most up-to-date information or where they were seen as authoritative statements. While the body of knowledge concerning volatile substance abuse has improved, little progress has been made in finding effective solutions to the problem. The fact that users are typically young and that there is a real risk of sudden death associated with even initial use suggests that continuing research is needed to develop innovative approaches to the problem.

Aerosol Propellants

Aerosol propellant interference with clinical mass spectrometers.

Metered dose inhalers containing halogenated propellants may interfere with mass spectrometer quantitation of halogenated inhalation anesthetics. We identify the propellant(s) in a commercially available metered dose inhaler that caused erroneous mass spectrometer readings. In addition, we identify the causes of different types of interference in different mass spectrometers.

Aerosol Propellants