Blue light endoscopy.

Abstract

The introduction of high intensity proximal light sources has greatly improved the already high standard in technique of endoscopy. The enable us to illuminate the periphery of the bronchi. The advantage of better illumination must, nevertheless, be paid for with a levelling of contrast, as the bright light outshines the fine differences (e.g., tubercles in yhr mucous membrane). In order to heighten the contrast, first theoretical, then practical tests were carried out with different colored lights. Filters (red, green, yellow and light blue) were placed in front of the light source and the subjective perceptible changes in contrast examined. These tests showed that the light blue filter gave a heightened contrast between light and dark red as well as between yellow and red. Intra- and submucosal nodules, scars, metaplasias, hyper- and parakeratoses as well as precancerous conditions are more clearly visible in the mucous membrane. Circumscribed lesions are better seen and specimens for histological vertification are more accurately located for biopsy. Foreign bodies are more easily grasped. The remaining filters heighten the contrast in special cases (such as mycosis and colored foreign bodies). Individual filters or multifilter disc placed between the light source and the glass fiber light carrier are easy to manipulate, so that colored light can be employed in routine bronchoscopy in order to improve diagnosis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Hürzeler. 1975. Blue light endoscopy.. https://doi.org/10.1288/00005537-197508000-00014

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Diagnostic value of the blind brush in mechanically ventilated patients with nosocomial pneumonia.

OBJECTIVES: To check on the accuracy of a new protected blind brush (BB) inserted through an endotracheal tube to collect respiratory secretions to be used in the diagnosis of nosocomial pneumonia (NP) in ventilated patients. DESIGN: Prospective study of patients who had undergone both BB and plugged telescoping catheter via fiberoptic bronchoscopy (PTC-FB) sample collection sessions. SETTING: Intensive Care Unit of a referral-based University Hospital. PATIENTS: All patients (n = 37) mechanically ventilated for more than 3 days with clinical and radiological criteria of NP between July 1990 and March 1991. INTERVENTIONS: Randomized BB and PTC-FB sample collection sessions carried out less than 30 min apart. MEASUREMENTS AND MAIN RESULTS: The two sampling procedures resulted in similar findings with both cultures either negative or positive and identified the same organism and colonies in 31 patients (83.7%). Agreement was 90% when the patients with right or bilateral pulmonary infiltrates were grouped together and 100% when only the right field was considered. Complications arising from BB sampling were much lower than those from the conventional PTC-FB technique. CONCLUSIONS: Our results, pending confirmation by other prospective studies, indicate that BB sampling is useful in the diagnosis of NP in ventilated patients with radiological evidence of either right or bilateral pulmonary infiltrates and that it could stand in for PTC-FB in ICU settings where this procedure is not available.

Bronchoscopes

A study of glutaraldehyde disinfection of fibreoptic bronchoscopes experimentally contaminated with Mycobacterium tuberculosis.

Mycobacteria are difficult to inactivate, and concern about the spread of tuberculosis at bronchoscopy has a major influence on infection control practices. Recommendations from the UK Department of Health are based largely on in-vitro mycobactericidal assays which do not take into account the particular conditions encountered in endoscopy units. In this applied study cleaning and disinfection methods were examined using five bronchoscopes that were heavily contaminated with a recent isolate of Mycobacterium tuberculosis in sputum. Cleaning reduced contamination by a mean 3.5 log(10) colony forming units (cfu) per ml; all bronchoscopes were free of detectable mycobacteria after 10 min in 2% alkaline glutaraldehyde (AG). It is recommended that all bronchoscopes be thoroughly pre-cleaned and disinfected in 2% AG for 20 min as part of a uniform policy of infection control.

Bronchoscopes