Reference data and predictive diagnostic models for calcaneus bone mineral density measured with single-energy X-ray absorptiometry in 7428 Chinese.

Abstract

Calcaneus bone mineral density (BMD) of 7428 Chinese (4126 women, 3302 men; aged 22-94 years) was measured using single-energy X-ray absorptiometry (SXA). A reference range of calcaneus BMD values for healthy Chinese men and women was established and the usefulness of this method for screening and diagnosis in osteoporosis was evaluated. The peak BMD occurred at 20-24 years old and peak BMD in women was significantly lower than in men. BMD loss in the calcaneus started at the age of 35 years for women, and at 63 years in men. BMD loss rate was 1.2%/year for women and 0.56%/year for men after 50 years. The young normal reference for calcaneus BMD was 442.1+/-69.6 mg/cm2 for men and 388.3+/-61.7 mg/cm2 for women calculated from the mean BMD value of subjects whose age ranged from 20 to 49 years. The accumulated BMD loss in the calcaneus is similar to that of Ward's triangle. Multiple linear regression showed that both age and weight were important factors. The incidence of osteoporosis in older men and women (> or = 60 years) is 6.6% and 32.1% respectively. We conclude that calcaneus BMD measurement is useful and sensitive for the screening and diagnosis of osteoporosis. A predictive diagnostic model for osteoporosis based on the calcaneus was constructed using multiple linear regression and the WHO criteria for diagnosing osteoporosis can be applied to calcaneus BMD.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Z Xu, W Zhou, X D Mao, J Xu, L P Xu, J Y Ren. 2001. Reference data and predictive diagnostic models for calcaneus bone mineral density measured with single-energy X-ray absorptiometry in 7428 Chinese.. https://doi.org/10.1007/s001980170052

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗