Abstract

Robotic technology is enhancing surgery through improved precision, stability, and dexterity. In image-guided procedures, robots use magnetic resonance and computed tomography image data to guide instruments to the treatment site. This requires new algorithms and user interfaces for planning procedures; it also requires sensors for registering the patient's anatomy with the preoperative image data. Minimally invasive procedures use remotely controlled robots that allow the surgeon to work inside the patient's body without making large incisions. Specialized mechanical designs and sensing technologies are needed to maximize dexterity under these access constraints. Robots have applications in many surgical specialties. In neurosurgery, image-guided robots can biopsy brain lesions with minimal damage to adjacent tissue. In orthopedic surgery, robots are routinely used to shape the femur to precisely fit prosthetic hip joint replacements. Robotic systems are also under development for closed-chest heart bypass, for microsurgical procedures in ophthalmology, and for surgical training and simulation. Although results from initial clinical experience is positive, issues of clinician acceptance, high capital costs, performance validation, and safety remain to be addressed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R D Howe, Y Matsuoka. 1999. Robotics for surgery.. https://doi.org/10.1146/annurev.bioeng.1.1.211

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A biological hybrid model for collagen-based tissue engineered vascular constructs.

Various approaches to tissue engineering a small diameter blood vessel have historically relied upon extended culturing periods and/or synthetic materials to create mechanical properties suitable to withstand the hemodynamic stresses of the vasculature. In this work, we present the concept of a construct-sleeve hybrid (CSH) graft, which uses a biological support to provide temporary reinforcement while cell-mediated remodeling of the construct occurs. Support sleeves were fabricated from Type I collagen gels and crosslinked with glutaraldehyde, ultraviolet, or dehydrothermal treatments. Uniaxial tensile testing of acellular sleeves revealed increased stiffness moduli and tensile stresses with crosslinking treatments. A second collagen layer containing cells was molded about the sleeve to create a CSH. After in vitro culture, CHSs with uncrosslinked (UnXL) and glutaraldehyde treated (Glut) sleeves exhibited significant increases in mechanical strength (20.4-fold and 121-fold increases in ultimate stress, respectively) compared to unreinforced control constructs. Burst testing produced similar findings with peak pressures of 100 and 650mmHg in the UnXL and Glut CSHs, respectively. Construct compaction, cell viability, and histological examination demonstrated that the function of most cells remained unimpaired with the incorporation of the biological support sleeve.

Biomedical Engineering↗

Hollow-bore needlestick injuries in a tertiary teaching hospital: epidemiology, education and engineering.

OBJECTIVE: To describe the frequency, cause and potential cost of prevention of hollow-bore dirty needlestick injury (NSI) sustained by healthcare workers. DESIGN AND PARTICIPANTS: Ten-year prospective surveillance study, 1990-1999, with triennial anonymous questionnaire surveys of nursing staff. SETTING: 800-bed university tertiary referral hospital in Brisbane, Australia. MAIN OUTCOME MEASURES: Rates and circumstances of NSI in medical, nursing and non-clinical staff; knowledge of NSI consequences in nurses; and minimum costs of safety devices. RESULTS: Between 1990 and 1999, there was a significant increase (P < 0.001) in the trend of the reported rate of NSI. Of the 1836 "dirty" NSIs reported, most were sustained in nursing (66.2%) and medical (16.8%) staff, with 62.7% sustained before disposal. Hollow-bore injuries from hypodermic needles (83.3%) and winged butterfly needles (9.8%) were over-represented. Knowledge among nursing staff of some of the risks and outcomes of NSI improved over the decade. A trend (chi(2 )= 9.89; df = 9; P = 0.0016) with increasing rate of reported injuries in this group was detected. The estimated cost of consumables only, associated with the introduction of self-retracting safety syringes with concomitant elimination of butterfly needles, where practicable, would be about $365 000 per year. CONCLUSION: More than one NSI occurs for every two days of hospital operation. Introduction of self-retracting safety syringes and elimination of butterfly needles should reduce the current hollow-bore NSI by more than 70% and almost halve the total incidence of NSI.

Biomedical Engineering↗

Roles for learning sciences and learning technologies in biomedical engineering education: a review of recent advances.

Education in biomedical engineering offers a number of challenges to all constituents of the educational process-faculty, students, and employers of graduates. Although biomedical engineering educational systems have been under development for 40 years, interest in and the pace of development of these programs has accelerated in recent years. New advances in the learning sciences have provided a framework for the reexamination of instructional paradigms in biomedical engineering. This work shows that learning environments should be learner centered, knowledge centered, assessment centered, and community centered. In addition, learning technologies offer the potential to achieve this environment with efficiency. Biomedical engineering educators are in a position to design and implement new learning systems that can take advantage of advances in learning science, learning technology, and reform in engineering education.

Biomedical Engineering↗