PubMed Health⌕ Search

PubMed · 11788219

Quantitative angiographic methods for appropriate end-point analysis, edge-effect evaluation, and prediction of recurrent restenosis after coronary brachytherapy with gamma irradiation.

Abstract

OBJECTIVES: The study was done to investigate the relationship between clinical restenosis and the relative angiographic location of the recurrent restenotic lesion, after treatment of in-stent restenosis with vascular brachytherapy in the Washington Radiation for In-Stent Restenosis Trial (WRIST). BACKGROUND: Intracoronary radiation therapy reduces recurrence of in-stent restenosis. We investigated the above objective in patients enrolled in WRIST. METHODS: The WRIST study randomized 130 patients to double-blinded therapy with gamma irradiation (iridium-192 [(192)Ir]) versus placebo after interventional treatment of diffuse in-stent restenosis. After the intervention and at follow-up, three vessel segments were individually analyzed with quantitative coronary angiography: 1) the "stent," 2) the "radiation ribbon," and 3) the "ribbon+margin" segment (including 5 mm on either end of the injured or radiation-ribbon segment). Receiver operator curves (ROC) were used to assess the value of the follow-up percent diameter stenosis (DS) for each of the three analyzed segments in predicting target vessel revascularization (TVR). RESULTS: (192)Ir reduced recurrent restenosis (23.7% vs. 60.7%, p < 0.001) and the length of recurrent restenosis (8.99 +/- 4.34 mm vs. 17.54 +/- 10.48 mm, p < 0.001) at follow-up compared to placebo. Isolated stent edge (3.4%) and ribbon edge (1.7%) restenoses were infrequent in both groups. The best angiographic surrogate of TVR was the 50% follow-up DS obtained from the ribbon+margin analysis (ROC area 0.806). CONCLUSIONS: In WRIST, not only was (192)Ir therapy effective in reducing restenosis, but it also reduced the lesion length of treatment failures by 50%, and it was not associated with edge proliferation. The restenosis rate obtained from the vessel segment inclusive of the dose fall-off zones was the best correlate of TVR and should become a standard analysis site in all vascular brachytherapy trials.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Alexandra J Lansky, George Dangas, Roxana Mehran, Kartik J Desai, Gary S Mintz, Hongsheng Wu, Martin Fahy, Gregg W Stone, Ron Waksman, Martin B Leon. 2002-01-16. Quantitative angiographic methods for appropriate end-point analysis, edge-effect evaluation, and prediction of recurrent restenosis after coronary brachytherapy with gamma irradiation.. https://doi.org/10.1016/s0735-1097(01)01745-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

CT-based postimplant dosimetry of prostate brachytherapy: comparison of 1-mm and 5-mm section CT.

PURPOSE: The aim of this study was to compare the outcomes between 1-mm and 5-mm section computed tomography (CT)-based postimplant dosimetry. MATERIALS AND METHODS: A series of 21 consecutive patients underwent permanent prostate brachytherapy. The postimplant prostate volume was calculated using 1-mm and 5-mm section CT. One radiation oncologist contoured the prostate on CT images to obtain the reconstructed prostate volume (pVol), prostate V(100) (percent of the prostate volume receiving at least the full prescribed dose), and prostate D(90) (mean dose delivered to 90% of the prostate gland). The same radiation oncologist performed the contouring three times to evaluate intraobserver variation and subjectively scored the quality of the CT images. RESULTS: The mean +/-1 SD postimplant pVol was 20.17 +/- 6.66 cc by 1-mm section CT and 22.24 +/- 8.48 cc by 5-mm section CT; the difference in the mean values was 2.06 cc (P < 0.01). The mean postimplant prostate V(100) was 80.44% +/- 7.06% by 1-mm section CT and 77.33% +/- 10.22% by 5-mm section CT. The mean postimplant prostate D(90) was 83.28% +/- 10.81% by 1-mm section CT and 78.60% +/- 15.75% by 5-mm section CT. In the evaluation of image quality, 5-mm section CT was assigned significantly higher scores than 1-mm section CT. In regard to intraobserver variation, 5-mm section CT revealed less intraobserver variation than 1-mm section CT. CONCLUSION: Our current results suggested that the outcomes of postimplant dosimetry using 1-mm section CT did not improved the results over those obtained using 5-mm section CT in terms of the quality of the CT image or reproducibility.

Brachytherapy↗

Long-term results of breast cancer irradiation treatment with low-dose-rate external irradiation.

PURPOSE: The aim of this study was to assess beam therapy with low-dose-rate (LDR) external irradiation in a group of patients with breast cancer. METHODS AND MATERIALS: This trial compared, from 1986 to 1989, patients with advanced breast cancer treated either by conventional fractionation or low-dose-rate (LDR) external radiotherapy (dose-rate 15 mGy/min, 5 sessions of 9 Gy delivered on 5 consecutive days). RESULTS: A total of 21 patients were included in the fractionated therapy arm. At follow-up 15 years after treatment, 7 local recurrences had occurred, 3 patients had died of cancer, 18 patients were alive, 10 were without evidence of disease, and 6 had evidence of disease. A total of 22 patients had been included in the LDR arm of the study. Of these, 11 had received a dose of 45 Gy; thereafter, in view of severe local reactions, the dose was reduced to 35 Gy. There was no local recurrence in patients who had received 45 Gy, although there were 2 local recurrences among the 11 patients after 35 Gy. The sequelae were severe in patients who received 45 Gy but were comparable to those observed in patients treated by fractionated radiotherapy who received 35 Gy. The higher efficacy of tumor control in patients treated by LDR irradiation as well as the lower tolerance of normal tissue are probably related to the lack of repopulation. CONCLUSION: Although the patient numbers in this study are limited, based on our study results we conclude that the data for LDR irradiation are encouraging and that further investigation is warranted.

Brachytherapy↗

Five-year outcome of intraoperative conformal permanent I-125 interstitial implantation for patients with clinically localized prostate cancer.

PURPOSE: To report the 5-year tumor control and toxicity outcomes for patients with localized prostate treated with I-125 permanent implantation using an intraoperative real-time conformal planning technique. METHODS AND MATERIALS: Between January 1998 and June 2002, 367 patients with prostate cancer were treated with I-125 permanent interstitial implantation using a transrectal ultrasound-guided approach. Real-time intraoperative treatment planning which incorporated inverse planning optimization was used. The median follow-up time was 63 months. RESULTS: The median V100 and D90 were 96% and 173 Gy, respectively. In 96% of cases a D90 of >140 Gy was achieved. The median urethral and rectal doses were 100% and 33% of the prescription doses, respectively. The 5-year PSA relapse-free survival outcomes for favorable and intermediate risk patients according to the ASTRO definition were 96% and 89%, respectively. In these patients no dosimetric parameter was identified which influenced the biochemical outcome. Of 38% who developed acute Grade 2 urinary symptoms, 63% had resolution of their symptoms within a median time of 6 months. The incidence of late rectal and urinary Grade 3 or higher toxicities were 1% and 4%, respectively. Seven percent (n = 27) developed late rectal bleeding (Grade 2) and 19% experienced late Grade 2 urinary symptoms. CONCLUSION: Real-time intraoperative planning consistently achieved optimal coverage of the prostate with the prescription dose with concomitant low doses delivered to the urethra and rectum. Biochemical control outcomes were excellent at 5 years and late toxicity was unusual. These data demonstrate that real-time planning methods can consistently and reliably deliver the intended dose distribution to achieve an optimal therapeutic ratio between the target and normal tissue structures.

Brachytherapy↗