PubMed Health⌕ Search

PubMed · 12002129

Predicting local cell deformations in engineered tissue constructs: a multilevel finite element approach.

Abstract

A multilevel finite element approach is applied to predict local cell deformations in engineered tissue constructs. Cell deformations are predicted from detailed nonlinear FE analysis of the microstructure, consisting of an arrangement of cells embedded in matrix material. Effective macroscopic tissue behavior is derived by a computational homogenization procedure. To illustrate this approach, we simulated the compression of a skeletal muscle tissue construct and studied the influence of microstructural heterogeneity on local cell deformations. Results show that heterogeneity has a profound impact on local cell deformations, which highly exceed macroscopic deformations. Moreover, microstructural heterogeneity and the presence of neighboring cells leads to complex cell shapes and causes non-uniform deformations within a cell.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Roel G M Breuls, Bram G Sengers, Cees W J Oomens, Carlijn V C Bouten, Frank P T Baaijens. 2002. Predicting local cell deformations in engineered tissue constructs: a multilevel finite element approach.. https://doi.org/10.1115/1.1449492

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

pH and cell volume effects on H2O and phosphoryl resonance splitting in rapid-spinning NMR of red cells.

Two resonances are seen in the (1)H-NMR spectrum of water in erythrocyte suspensions spun at the magic angle, a broad signal from water inside the cells and a sharp signal from extracellular water. The splitting is a result of a true chemical shift difference between the two populations, as bulk magnetic susceptibility effects are negated at the magic angle. The pH dependence of this chemical shift difference in erythrocyte suspensions was investigated. Splittings of 16.7 +/- 0.1, 18.9 +/- 0.9, and 21.0 +/- 0.2 Hz were observed at pH 6.0, 7.0, and 8.5, respectively; however, this was accompanied by a change in the mean cell volume. To account for any contribution from the volume change, the osmolality of the pH 6.0 and 8.5 suspensions was adjusted to equalize the cell volume between samples at the three pHs. Under these conditions, the splitting was 18.3 +/- 0.1 and 18.6 +/- 0.1 Hz at pH 6.0 and 8.5, respectively. Thus the observed chemical shift difference between the two water resonances was independent of pH. Therefore the splitting of the water resonance was concluded to be directly proportional to the protein concentration within the cell. Measurements of the magnetic susceptibility difference between the two compartments were also carried out, yielding a value of 2.0 +/- 0.2 x 10(-7) (SI units) for erythrocytes in isotonic saline at pH 7.0.

Cell Size↗

Correlation between erythrocytes deformability and size: a study using a microchannel based cell analyzer.

The deformability of erythrocytes is of great importance for oxygen delivery in the microcirculation [Lipowsky, H.H., 2005. Microvascular rheology and hemodynamics. Microcirculation 12, 5-15]. Aging of erythrocytes is associated with a reduction in deformability and also in size. The present work describes an automated cell analyzer which utilizes a glass microchannel and advanced image processing software. Erythrocytes suspended in a high viscosity medium are filmed flowing through the microchannel. Under these conditions, the cells assume different orientations and undergo varying deformations according to their location in the velocity profile. The cell analyzer enables the measurement of individual erythrocyte velocity, deformability and volume at varying depths within the microchannel. The volume of the cells is calculated based on the experimental data and a fluid mechanics model. The results obtained show that, on average, the deformability of the cells increases with increase in their size. Additionally, the behavior of RBCs in a microchannel is investigated, showing promising diagnostic possibilities.

Cell Size↗

Microtubule organization in three-dimensional confined geometries: evaluating the role of elasticity through a combined in vitro and modeling approach.

Microtubules or microtubule bundles in cells often grow longer than the size of the cell, which causes their shape and organization to adapt to constraints imposed by the cell geometry. We test the reciprocal role of elasticity and confinement in the organization of growing microtubules in a confining box-like geometry, in the absence of other (active) microtubule organizing processes. This is inspired, for example, by the cortical microtubule array of elongating plant cells, where microtubules are typically organized in an aligned array transverse to the cell elongation axis. The method we adopt is a combination of analytical calculations, in which the polymers are modeled as inextensible filaments with bending elasticity confined to a two-dimensional surface that defines the limits of a three-dimensional space, and in vitro experiments, in which microtubules are polymerized from nucleation seeds in microfabricated chambers. We show that these features are sufficient to organize the polymers in aligned, coiling configurations as for example observed in plant cells. Though elasticity can account for the regularity of these arrays, it cannot account for a transverse orientation of microtubules to the cell's long axis. We therefore conclude that an additional active, force-generating process is necessary to create a coiling configuration perpendicular to the long axis of the cell.

Cell Size↗