PubMed Health⌕ Search

PubMed · 12464921

Conversion to digital technology improves efficiency in the pediatric echocardiography laboratory.

Abstract

BACKGROUND: Although the videotape method (VTM) is commonly used to record and intrepret ecocardiographic images, many pediatric echocardiographers are considering acquiring to, interpreting from, and storing their images to digital disk using the single-beat digital acquisition method (SBM). The paucity of image redundancy using SBM should translate into improved laboratory efficiency compared with VTM, but hard data are lacking. The purpose of this study was to test the hypothesis that the time to acquire images to videotape using VTM and to disk using SBM would be the same for normal hearts and corresponding congenital heart diseases, but interpretation times would be shorter using SBM. METHODS: We measured the times to acquire and interpret 403 echocardiograms using standard VTM from Children's Hospital in Cincinnati, Ohio, and 352 echocardiograms acquired using SBM from Children's Hospital in San Diego, Calif. Diagnostic categories at each site included: (1) normal, (2) simple shunt or isolated valve disease, and (3) multiple-lesion disease. RESULTS: As a group, SBM echocardiograms included more hemodynamic measurements and took more time to acquire (P <.037), but less time to read (P <.001) than corresponding images acquired using VTM. Using SBM, it took more time to acquire normals and isolated valve or shunt lesions, whereas the average time to acquire multiple-lesion disease was the same using both VTM and SBM. With SBM, in contrast, interpretation times were significantly less for all corresponding diagnoses. CONCLUSION: SBM studies took longer to acquire because more hemodynamic measurements were acquired, but they were read in less time than corresponding VTM studies even though all videotapes were replayed in search fast-forward mode. Pediatric echocardiographers can increase their laboratory efficiency by converting from VTM to SBM.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

James W Mathewson, Dan Dyar, Frederick D Jones, Mark S Sklansky, James C Perry, Erik C Michelfelder, Linda Cripe, Thomas R Kimball. 2002. Conversion to digital technology improves efficiency in the pediatric echocardiography laboratory.. https://doi.org/10.1067/mje.2002.129498

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A user-friendly PC-based data acquisition and analysis system for respirometric investigations.

We have developed an easy-to-use computer-based system for recording, displaying, storing and analyzing signals generated by Clark-type oxygen electrodes. A user-friendly interface of Windows-based program BioMed significantly increases the productivity of investigations. It allows to process, control, present and archive the experimental data in real time. A 12-bit analog-to-digital-converter, analog and digital filters, a possibility to zoom the obtained respiratory curves and calculation of the respiration rates by a linear regression method increase the resolution of the estimated oxygen consumption rates. The new system enables to register even small changes, such as 3-5 ngatoms O/min, in respiration rates of biological objects -- enzymes, mitochondria and permeabilized muscle fibers. The system has been developed and is regularly used for the respirometric investigations at the Laboratory of Biochemistry, Institute for Biomedical Research, Kaunas University of Medicine.

Analog-Digital Conversion↗

Elimination of depth degeneracy in optical frequency-domain imaging through polarization-based optical demodulation.

A novel optical frequency-domain imaging system is demonstrated that employs a passive optical demodulation circuit and a chirped digital acquisition clock derived from a voltage-controlled oscillator. The demodulation circuit allows the separation of signals from positive and negative depths to better than 50 dB, thereby eliminating depth degeneracy and doubling the imaging depth range. Our system design is compatible with dual-balanced and polarization-diverse detection, important techniques in the practical biomedical application of optical frequency-domain imaging.

Analog-Digital Conversion↗