Colour centres in plasma-sprayed hydroxyapatite.

Abstract

Very pure hydroxyapatite is diamagnetic and shows no electron paramagnetic resonance (EPR) spectrum. Plasma-sprayed coatings made with such a pure hydroxyapatite contain paramagnetic point-defects. Irradiated deposits show a strong EPR absorption assigned to an O2- anion adjacent to a calcium vacancy, with anisotropic parameters, g1 = 2.004, g2 = 2.013 and g3 = 2.038. The EPR spectra and colour fade away following thermal annealing. These features are discussed in terms of point-defects in the hydroxyapatite crystal structure.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Sharrock, G Bonel. 1992. Colour centres in plasma-sprayed hydroxyapatite.. https://doi.org/10.1016/0142-9612(92)90013-e

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Readability and sensitivity of a new faecal occult blood test in a hospital ward environment. Comparison with an established test.

OBJECTIVE: To compare the readability and sensitivity of a new guaiac faecal occult blood test, HemoccultSENSA, with those of a standard guaiac-based test, Hemoccult, in a normal working environment. DESIGN: The two tests were performed in parallel on routine clinical and contrived faecal specimens; those developing the tests were blinded as to the test type. SETTING: All tests were carried out in the hospital ward environment under normal conditions by nurses working in the ward. SAMPLES: Fifty faecal samples from healthy volunteer subjects (low concentrations of haemoglobin were added to 40 of these samples) and 145 faecal samples from 65 inpatients likely to have gastrointestinal bleeding. MAIN OUTCOME MEASURES: Test positivity rate, and graded measures of colour intensity, colour stability and colour pattern. RESULTS: With patients' samples, the new test gave a greater number of positive results than the standard test (73.1% v. 65.5%; 95% confidence interval of the difference, 3.3%-11.9%). With contrived samples, the blue colour produced during development was more intense (P less than 0.0003), more stable (P less than 0.0025) and covered a larger area (P less than 0.01) with the new test compared with the standard test. CONCLUSIONS: These results demonstrate the better readability and slightly higher sensitivity of the new test. They justify its use in the ward environment or doctor's office. Patients being tested should consume a low peroxidase diet until the specificity of the new test has been fully evaluated.

Color