PubMed Health⌕ Search

PubMed · 13678293

When the "detection efficiency" is not the "detection" efficiency.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Joseph J Shonka, Don M DeBord, Javid L Kelley, Michael R Marcial. 2003. When the "detection efficiency" is not the "detection" efficiency.. https://doi.org/10.1097/00004032-200310000-00017

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Systematic study of long-term stability of 3,4-dihydroxyphenylglycol in plasma for subsequent determination with liquid chromatography.

The effect of three storage temperature levels (i.e. +4, -20 and -80 degrees C) and time intervals from sampling (3, 6 and 9 months) on the degradation of 3,4-dihydroxyphenylglycol (DHPG) and norepinephrine (NE) was investigated in a systematic study. Extracted human plasma samples and acidified standard solutions were stored for long periods (up to 9 months) without the addition of any stabilizing agent. DHPG and NE values, determined using a ion-pair reversed-phase high-performance liquid chromatography method with electrochemical detection of coulometric type (IP-RP-HPLC-CD), remained constant over time in those plasma samples and standard solutions that had been stored at the lowest storing temperature (i.e. -80 degrees C). The expected degradation was observed at higher temperature levels. Plasma and standard DHPG degradation can, therefore, be prevented by storing samples at a lower temperature than previously suggested with no need to add any stabilizing agent.

Calibration↗

Analysis of glycerophosphoinositol by liquid chromatography-electrospray ionisation tandem mass spectrometry using a beta-cyclodextrin-bonded column.

Glycerophosphoinositol (GroPIns) has been demonstrated to have important roles in many intracellular regulatory processes. GroPIns has been analysed for many years by anion-exchange HPLC after radiolabelling of cells in culture, but no method has been developed, to our knowledge, for the direct detection and quantitation of the unlabelled compound in such biological samples. Here is reported a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the direct quantitative analysis of GroPIns that can indeed be applied to cell extracts. Analyses were performed on a beta-cyclodextrin-bonded HPLC column using a binary mobile phase of acetonitrile and 20 mM ammonium formate in water, which allowed direct on-line detection by tandem mass spectrometry in negative electrospray ionisation (ESI) mode. The method was applied to the quantitative analysis of GroPIns in selected rat cell lines after a two-phase acid extraction of cultured cells using external calibration. The potential matrix signal suppression effects were investigated by the parallel quantitation of GroPIns in extracts of selected cultured cell lines with both external calibration and the standard additions method. The accuracy data obtained demonstrated the feasibility of external calibration, so allowing a simpler and less time-consuming approach than that of the standard additions method.

Calibration↗

Simultaneous determination of levodopa and 3-O-methyldopa in human plasma by liquid chromatography with electrochemical detection.

A simple and rapid assay is described for the simultaneous analysis of levodopa (l-DOPA) and 3-O-methyldopa (3-OMD) in human plasma samples, applying an ion-pair reversed-phase liquid chromatographic method with electrochemical detection, designed for clinical trials performed to study the effect of peripheral catechol-O-methyltransferase inhibitors on the metabolism of l-DOPA. After protein precipitation of 100 microl plasma sample aliquots with perchloric acid, the analytes are directly injected, separated within 10 min and simultaneously quantified down to 20 ng/ml by an electrochemical detector equipped with a dual-electrode system operating in redox mode eliminating effectively potential endogenous and exogenous interferences. The intra-assay precision for l-DOPA and 3-OMD was 1.34-6.54 and 3.90-5.50%, whereas the inter-assay precision was 2.09-7.69 and 4.16-9.90%, respectively. The recoveries were close to 90% for l-DOPA and almost 100% for 3-OMD. Satisfactory storage stability was achieved for up to 16 weeks at -70 degrees C by stabilizing plasma samples with antioxidants.

Calibration↗