PubMed Health⌕ Search

PubMed · 14597337

Localized harmonic motion imaging: theory, simulations and experiments.

Abstract

Several techniques have been developed in an effort to estimate mechanical properties of tissues. These techniques typically estimate static or harmonic motion resulting from an externally or internally applied mechanical stimulus. In this paper, we discuss the advantages of utilizing a new technique that performs radiofrequency (RF) signal tracking to estimate the localized oscillatory motion resulting from the harmonic radiation force produced by two focused ultrasound (US) transducer elements with overlapping beams oscillating at distinct frequencies. Finite-element and Monte-Carlo simulations were performed to characterize the range of oscillatory displacements produced by a harmonic radiation force. In the experimental verification, three transducers were used: two single-element focused transducers and one lead zirconate-titanate (PZT) composite 16-element probe. Four agar gels were utilized to determine the effect of stiffness on the motion amplitude. Estimates of the displacement relative to the initial position (i.e., at the onset of the application of the radiation force) were obtained during the application of the radiation force that oscillated at frequencies ranging between 200 Hz and 800 Hz. In the simulations, the estimated oscillatory displacement spanned from -800 to 600 microm and the frequencies of excitation could easily be estimated from the temporal variation of the displacement. In addition, a frequency upshift (on the order of tens of Hz) was estimated with stiffness increase. Furthermore, an exponential decrease of the displacement amplitude with stiffness was observed at all frequencies investigated. An M-mode version to depict both the spatial and temporal variations of the locally induced displacement was used. In experiments with gels of different stiffness, the resulting amplitude of the harmonic displacement estimated oscillated at the same frequencies and ranged from -300 to 250 microm. An exponential decrease of the displacement amplitude with the gel stiffness was also observed. In tissue experiments, the results showed that the method is feasible in tissues and that focused US surgery (FUS) ablation can be detected. These preliminary results demonstrate the feasibility of imaging localized harmonic motion as induced by an oscillatory US radiation force. Due to the highly localized and harmonic nature of the estimated response, this technique may be proven to be highly suitable for simple and accurate estimation of the elastic modulus variation in tissues due to disease.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Elisa E Konofagou, Kullervo Hynynen. 2003. Localized harmonic motion imaging: theory, simulations and experiments.. https://doi.org/10.1016/s0301-5629(03)00953-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fabrication of agar-gelatin hybrid scaffolds using a novel entrapment method for in vitro tissue engineering applications.

Scaffolds of agar and gelatin were developed using a novel entrapment method where agar and gelatin molecules mutually entrapped one another forming stable cell adhesive matrices. Glutaraldehyde was used as a crosslinking agent for gelatin. Three types of hybrid matrices were prepared using agar and gelatin in different proportions in the weight ratio of 1:1, 2:1, and 3:1. Surface characterization of dry scaffolds was carried out by scanning electron microscope. Swelling studies were carried out in phosphate buffer saline (PBS) at physiological pH 7.4. The integral stability of the scaffolds was evaluated by estimating the released disintegrated gelatin from them in PBS at pH 7.4. The attachment kinetics of the cells was evaluated by culturing mouse fibroblast cell line NIH 3T3 on films. The cytocompatibility of these matrices was determined by studying growth kinetics of NIH 3T3 cells on them and morphology of cells was observed through optical photographs taken at various days of culture. It was found that the matrices containing agar and gelatin in 2:1 weight ratio exhibited best growth kinetics. The results obtained from these studies have suggested that the above-described method is a cheap and easy way to fabricate agar-gelatin hybrid scaffolds to grow cells which can be used in various in vitro tissue engineering applications like screening of drugs.

Agar↗

Interrelationships between colonies, biofilms, and planktonic cells of Pseudomonas aeruginosa.

Pseudomonas aeruginosa is a gram-negative bacterium and an opportunistic human pathogen that causes chronic infections in immunocompromised individuals. These infections are hard to treat, partly due to the high intrinsic resistance of the bacterium to clinically used antibiotics and partly due to the formation of antibiotic-tolerant biofilms. The three most common ways of growing bacteria in vitro are as planktonic cultures, colonies on agar plates, and biofilms in continuous-flow systems. Biofilms are known to express genes different from those of planktonic cells, and biofilm cells are generally believed to closely resemble planktonic cells in stationary phase. However, few, if any, studies have examined global gene expression in colonies. We used a proteomic approach to investigate the interrelationships between planktonic cells, colonies, and biofilms under comparable conditions. Our results show that protein profiles in colonies resemble those of planktonic cells. Furthermore, contrary to what has been reported previously, the protein profiles of biofilms were found to more closely resemble those of exponentially growing planktonic cells than those of planktonic cells in the stationary phase. These findings raise some intriguing questions about the true nature of biofilms.

Agar↗

Methods for additive hydration allowing observation of fully hydrated state of wet samples in environmental SEM.

Methods for additive hydration are presented that enable longtime observation of very wet biological specimens in an environmental scanning electron microscope. The changes of structure due to dehydration for specimens placed on a Peltier-cooled holder, put on a special agar base or embedded in it or blown over by water vapor are compared. The degree of dehydration damage of the observed specimen structures is evaluated and compared with the structure of a nondestructively dried specimen, prepared by the critical point drying method.

Agar↗