PubMed Health⌕ Search

PubMed · 14677773

Talc functionality as lubricant: texture, mean diameter, and specific surface area influence.

Abstract

Talc is widely used as a glidant (flow regulator) for powders. This study highlights the characteristics that confer to talcs new end use properties in improving the lubrication function during compression. We studied the contribution of texture, mean diameter (D50), and specific surface area on the residual die pressure, the ejection pressure, the lubrication index, and the tablet hardness. Different textures were studied: microcrystalline, macrocrystalline, and moderately macrocrystalline talc grade. The compression parameters were improved according to the texture. D50 varies from 0.62 to 15 microm. As D50 decreases, the lubrication performance is improved. Finally, the specific surface area of talcs was studied. This last characteristic of talcs was shown as the most relevant parameter in determining lubrication ability.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Ribet, K Poret, D Arseguel, D Chulia, F Rodriguez. 2003. Talc functionality as lubricant: texture, mean diameter, and specific surface area influence.. https://doi.org/10.1081/ddc-120025870

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Initial studies of water granulation of eight grades of hypromellose (HPMC).

The purpose of this study is to investigate the water granulation mechanism of the hydrophilic matrix polymer HPMC in a high shear mixer and to relate the properties of the granules and tablets to the molecular weight and the degree of substitution for eight HPMC grades. Although the hydrophilic matrix system is a well known drug delivery one, there is a difficulty in that the desirable water granulation technique often causes problems in the presence of relatively large amounts of HPMC due to its hydrophilicity. The results of this study show that the properties of the granules and the tablets fall into two groups according to whether the molecular weight of the polymer is high or low. The granules of low molecular weight were smaller and more compact, with better flow properties but with less tensile strength of the compacts, whereas the opposite was valid for granules of high molecular weight. The explanation for these differences is linked to the proposed granulation mechanism of HPMC, in which the properties of the gel layer are important. The dominant factors governing the properties are the molecular weight and, to lesser extent, the degree of substitution.

Excipients↗

Simultaneous determination of formic acid and formaldehyde in pharmaceutical excipients using headspace GC/MS.

Formic acid and its esters, as well as formaldehyde, are trace impurities that are often present in pharmaceutical excipients. These trace impurities can potentially react with amino and/or hydroxyl groups in drugs to form significant levels of degradants. To select the appropriate excipients for a stable formulation, a gas chromatography/mass spectrometry (GC/MS) method was developed and validated for the rapid screening of trace amounts of residual formic acid, its esters and formaldehyde in pharmaceutical excipients. Samples were dissolved or dispersed in acidified ethanol to convert formic acid and formaldehyde to ethyl formate and diethoxymethane, respectively. Identification was conducted using a GC/MS system under scan mode and quantified using a selected ion monitoring (SIM) mode. Evaluation of the mass spectra of ethyl formate and diethoxymethane in the samples indicated that the method is specific. The limits of quantitation of the method were 0.5 ppm for formic acid and 0.2 ppm for formaldehyde. The precision of the method was demonstrated by the acceptable R.S.D. (<or=10%) over a linear range of 0.5-10,000 ppm. The accuracy of the method was within 80-120% over the linearity range. The amounts of formic acid and formaldehyde in commonly used pharmaceutical excipients is reported.

Excipients↗

The effect of gamma-irradiation on PLGA/PEG microspheres containing ovalbumin.

Poly(ethylene glycol) (PEG) and sodium chloride (NaCl) are excipients used in PLGA microsphere preparation to stabilize proteins and reduce their burst release. No information is till now available in the literature on the effect due to the use of such excipients on the biopharmaceutical performance of gamma-irradiated microparticulate systems. On this purpose, different batches of microspheres containing ovalbumin (OVA) were prepared by using a PLGA 50:50 (average Mr: 13000), different amounts of PEG (Mr: 400 or 4000) and/or sodium chloride. The non-irradiated and irradiated microspheres were characterized in terms of morphology (SEM, particle size distribution), OVA and PEG content and in vitro OVA release. Radiolysis mechanisms of OVA and OVA loaded microspheres were investigated by EPR analysis. Gamma irradiation affects either microsphere morphology or the release of OVA as a function of the amount of PEG, and the use of NaCl. Irradiation significantly reduces release rate of protein from the microspheres containing 15% and 30% of PEG and from controls (microspheres without additives), while no significative effect on protein release rate is highlighted on microspheres containing lower amounts of PEG. EPR investigation shows that increasing amounts of PEG up to 30% have a perturbation effect on OVA radiolysis path.

Excipients↗