PubMed Health⌕ Search

PubMed · 14692221

Predictable esthetic indirect restorations.

Abstract

Patients are increasingly requesting esthetic tooth-colored restorations. Direct composite restorations have limitations based on the size of the restoration, the ability of the patient to tolerate procedures, and the ability of the dentist to provide functional restorations. The indirect composite restoration is ideal for replacing multiple failing restorations in teeth with existing restorations that are too large to be restored with direct composite restorations, yet too small to warrant the preparation for complete crowns.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Daniel H Ward. 2003. Predictable esthetic indirect restorations.. https://pubmed.ncbi.nlm.nih.gov/14692221/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of the hydrophilic nanofiller loading on the mechanical properties and the microtensile bond strength of an ethanol-based one-bottle dentin adhesive.

This study evaluated the hypothesis that if hydrophilic nanofillers were dispersed evenly within the adhesive layer under moist conditions, adding them to a one-bottle dentin adhesive might improve the mechanical properties of the adhesive layer, and accordingly increase the bond strength. The flexural strength (FS), the degree of conversion (DC), and the microtensile bond strength (MTBS) to the dentin of four experimental ethanol-based one-bottle dentin adhesives containing 0, 0.5, 1.0, and 3.0 wt % of 12-nm hydrophilic fumed silica were evaluated, and the distribution of the nanofillers were compared using transmission electron microscopy (TEM). Although the nanofiller content did not affect the DC, the FS tended to increase with increasing nanofiller content. The MTBS appeared to increase when up to 1.0 wt % of the nanofillers were added, but they were statistically not significant. However, when 3.0 wt % of the nanofillers were added, the MTBS decreased significantly comparing to the adhesive containing 0.5 wt % nanofillers (p < 0.05). The TEM image suggested that if the nanofillers within the adhesive were 3.0 wt % and applied to a wet dentin surface, they aggregated easily into large clusters and would decrease the MTBS.

Cementation↗

Effect of preparation convergence on retention and seating discrepancy of complete veneer crowns.

The purpose of this study was to evaluate the retention and marginal seating discrepancy of complete veneer crown cemented with zinc phosphate cement using various preparation convergence designs. The method employed was that of cementing cast metal crowns onto 46 metal dies fabricated as complete veneer crown preparations with various convergence angles ranging from 0 degrees to 70 degrees and a shoulder finish line. The marginal discrepancy was calculated by measuring the change in crown height before and after cementation using an optical measuring microscope. The force required to remove the crowns from the dies in a vertical direction was determined using an Instron universal testing machine and recorded as retention. The increase in preparation convergence exhibited a wide variation of seating discrepancy between specimens, ranging from 4.58 +/- 1.13 to 73.13 +/- 78.32 microm. Significant tilting of crown was observed as the convergence angle of preparation increased. The retention values ranged from 4.03 +/- 0.61 to 12.12 +/- 0.33 MPa. The Pearson analysis revealed statistically significant correlations between preparation convergence and marginal discrepancy (r = +0.62), and retention (r = -0.91). Crown retention and marginal discrepancy were influenced by the preparation convergence design.

Cementation↗

Radioactively contaminated electric arc furnace dust as an addition to the immobilization mortar in low- and medium-activity repositories.

Electric arc furnace dust (EAFD), generated by the steel-making industry, is in itself an intrinsic hazardous waste; however, the case may also be that scrap used in the process is accidentally contaminated by radioactive elements such as cesium. In this case the resulting EAFD is to be handled as radioactive waste, being duly confined in low- and medium-activity repositories (LMAR). What this paper studies is the reliability of using this radioactive EAFD as an addition in the immobilization mortar of the containers of the LMAR, that is, from the point of view of the durability. Different mixes of mortar containing different percentages of EAFD have been subjected to flexural and compressive strength, initial and final setting time, XRD study, total porosity and pore size distribution, determination of the chloride diffusion coefficient, dimensional stability tests, hydration heat, workability of the fresh mix, and leaching behavior. What is deduced from the results is that for the conditions used in this research, (cement + sand) can be replaced by EAFD upto a ratio [EAFD/(cement + EAFD)] of 46% in the immobilization mortar of LMAR, apparently without any loss in the long-term durability properties of the mortar.

Cementation↗